Analyzing the Impacts of Wind Generator on the Optimal Coordination of Overcurrent Relays

2012 ◽  
Vol 516-517 ◽  
pp. 1316-1321
Author(s):  
Ming Ta Yang ◽  
Jin Lung Guan ◽  
Jhy Cherng Gu

Wind generator and distribution systems after interconnection would change the short circuit fault characteristics of the original system and may lead to protection relay malfunctions, and review of the protection coordination. It is necessary to research the impact of existing protection strategies for distribution systems after wind generator interconnection. Linear programming methods were adopted for this study to review the coordination problems among feeder circuit breaker, lateral circuit breaker, and power fuse after radial distribution systems and wind generator interconnections.

Energies ◽  
2020 ◽  
Vol 13 (2) ◽  
pp. 334
Author(s):  
Esteban Pulido ◽  
Luis Morán ◽  
Felipe Villarroel ◽  
José Silva

In this paper, a new concept of short-circuit current (SCC) reduction for power distribution systems is presented and analyzed. Conventional fault current limiters (FCLs) are connected in series with a circuit breaker (CB) that is required to limit the short-circuit current. Instead, the proposed scheme consisted of the parallel connection of a current-controlled power converter to the same bus intended to reduce the amplitude of the short-circuit current. This power converter was controlled to absorb a percentage of the short-circuit current from the bus to reduce the amplitude of the short-circuit current. The proposed active short-circuit current reduction scheme was implemented with a cascaded H-bridge power converter and tested by simulation in a 13.2 kV industrial power distribution system for three-phase faults, showing the effectiveness of the short-circuit current attenuation in reducing the maximum current requirement in all circuit breakers connected to the same bus. The paper also presents the design characteristics of the power converter and its associated control scheme.


Author(s):  
Lazhar Bougouffa ◽  
Abdelaziz Chaghi

<p>Protective relays coordination is the process of determining the exact relay settings such that the relay closes to the fault would operates faster than other relays. The operating time of each relay depends on two independent variables called Pickup current (Ip) and Time Dial Setting (TDS). In this paper, a PSO algorithm has been presented to determine the coordination of Directional Over-Current Relays (DOCRs) in presence of multi-system FACTS devises. From the simulation result and analysis, the impact of TCSC location in the in 33-bus distribution system on Directional Over-Current Relays has been observed on the optimal relays settings as well as the effectiveness of the proposed algorithm in finding optimal coordination of directional over-current relays.</p>


Energies ◽  
2019 ◽  
Vol 12 (16) ◽  
pp. 3202
Author(s):  
Alberto Escalera ◽  
Edgardo D. Castronuovo ◽  
Milan Prodanović ◽  
Javier Roldán-Pérez

Modern power distribution networks assume the connection of Distributed Generators (DGs) and energy storage systems as well as the application of advanced demand management techniques. After a network fault these technologies and techniques can contribute individually to the supply restoration of the interrupted areas and help improve the network reliability. However, the optimal coordination of control actions between these resources will lead to their most efficient use, maximizing the network reliability improvement. Until now, the effect of such networks with optimal coordination has not been considered in reliability studies. In this paper, DGs, energy storage and demand management techniques are jointly modelled and evaluated for reliability assessment. A novel methodology is proposed for the calculation of the reliability indices. It evaluates the optimal coordination of energy storage and demand management in order to reduce the energy-not-supplied during outages. The formulation proposed for the calculation of the reliability indices (including the modelling of optimal coordination) is described in detail. The methodology is applied to two distribution systems combining DGs, energy storage and demand management. Results demonstrate the capability of the proposed method to assess the reliability of such type of networks and emphasise the impact of the optimal coordination on reliability.


2017 ◽  
Vol 2017 ◽  
pp. 1-6
Author(s):  
Chang Liu ◽  
Xiangyu Lv ◽  
Li Guo ◽  
Lixia Cai ◽  
Kuo Su

With the increase of penetration of distribution in distribution systems, the problems of power loss increase and short-circuit capacity beyond the rated capacity of the circuit breaker will become more serious. In this paper, a methodology (modified BPSO) is presented for network reconfiguration which is based on the hybrid approach of Tabu search and BPSO algorithms to prevent the local convergence and to decrease the calculation time using double fitness to consider the constraints. Moreover, an average load simulated method (ALS method) considering load variation is proposed such that the average load value is used instead of the actual load for calculation. Finally, from a case study, the results of simulation certify that the approaches will decrease drastically the losses and improve the voltage profiles obviously; at the same time, the short-circuit capacity is also decreased into smaller shut-off capacity of the circuit breaker. The power losses will not be increased too much even if the short-circuit capacity constraint is considered; voltage profiles are better with the constraint of short-circuit capacity considered. The ALS method is simple and the calculation time is fast.


2021 ◽  
Vol 11 (19) ◽  
pp. 9207
Author(s):  
Sergio D. Saldarriaga-Zuluaga ◽  
Jesús M. López-Lezama ◽  
Nicolás Muñoz-Galeano

In recent years, distributed generation (DG) has become more common in modern distribution networks (DNs). The presence of these small-scale generation units within a DN brings new challenges to protection engineers, since short-circuit currents tend to increase; additionally, as with microgrids, modern DNs may feature several operational modes depending on their topology and the availability of DG. This paper presents a methodology for the optimal coordination of overcurrent relays (OCRs) in modern DNs with a high presence of DG. Given the fact that protection coordination is a non-linear and non-convex optimization problem, a hybrid harmony search and simulated annealing (HS-SA) approach was implemented for its solution and compared against other techniques, such as conventional HS, genetic algorithm (GA), particle swarm optimization (PSO) and hybrid PSO-HS. Several tests were performed on a DN, considering different operative scenarios as a function of the DG available within the network. A comparison with other works reported in the specialized literature was carried out, evidencing the applicability and effectiveness of the HS-SA technique in solving the optimal OCR coordination problem in modern DNs.


2012 ◽  
Vol 2012 ◽  
pp. 1-9 ◽  
Author(s):  
Xiangyang Ye ◽  
Mahesh Dhotre

A high-voltage circuit breaker is an indispensable piece of equipment in the electric transmission and distribution systems. Transonic flow typically occurs inside breaking chamber during the current interruption, which determines the insulating characteristics of gas. Therefore, accurate compressible flow simulations are required to improve the prediction of the breakdown voltages in various test duties of high-voltage circuit breakers. In this work, investigation of the impact of the solvers on the prediction capability of the breakdown voltages in capacitive switching is presented. For this purpose, a number of compressible nozzle flow validation cases have been presented. The investigation is then further extended for a real high-voltage circuit breaker geometry. The correlation between the flow prediction accuracy and the breakdown voltage prediction capability is identified.


Sign in / Sign up

Export Citation Format

Share Document