Non-Invasive Analysis of the Micro-Structural and Biomechanical Properties of Trabecular Bone in Human Femoral Head

2006 ◽  
Vol 321-323 ◽  
pp. 1070-1073
Author(s):  
Ye Yeon Won ◽  
Myong Hyun Baek ◽  
Wen Quan Cui ◽  
Kwang Kyun Kim

This study investigates micro-structural and mechanical properties of trabecular bone in human femoral head with and without osteoporosis using a micro-CT and a finite element model. 15 cored trabecular bone specimens with 20 of diameter were obtained from femoral heads with osteoporosis resected for total hip arthroplasty, and 5 specimens were removed from femoral head of cadavers, which has no history of musculoskeletal diseases. A high-resolution micro-CT system was used to scan each specimen to obtain histomorphometry indexes. Based on the micro-images, a FE-model was created to determine mechanical property indexes. While the non-osteoporosis group had increases the trabecular thickness, the bone volume, the bone volume fraction, the degree of anisotropy and the trabecular number compared with those of osteoporotic group, the non-osteoporotic group showed decreases in trabecular separation and structure model index. Regarding the mechanical property indexes, the reaction force and the Young's modulus were lower in the osteoporotic group than in non-osteoporotic group. Our data shows salient deteriorations in trabecular micro-structural and mechanical properties in human femoral head with osteoporosis.

2006 ◽  
Vol 129 (4) ◽  
pp. 481-486 ◽  
Author(s):  
Chi Hyun Kim ◽  
Henry Zhang ◽  
George Mikhail ◽  
Dietrich von Stechow ◽  
Ralph Müller ◽  
...  

Microimaging based finite element analysis is widely used to predict the mechanical properties of trabecular bone. The choice of thresholding technique, a necessary step in converting grayscale images to finite element models, can significantly influence the predicted bone volume fraction and mechanical properties. Therefore, we investigated the effects of thresholding techniques on microcomputed tomography (micro-CT) based finite element models of trabecular bone. Three types of thresholding techniques were applied to 16-bit micro-CT images of trabecular bone to create three different models per specimen. Bone volume fractions and apparent moduli were predicted and compared to experimental results. In addition, trabecular tissue mechanical parameters and morphological parameters were compared among different models. Our findings suggest that predictions of apparent mechanical properties and structural properties agree well with experimental measurements regardless of the choice of thresholding methods or the format of micro-CT images.


Author(s):  
Lauren Bohner ◽  
Pedro Tortamano ◽  
Norbert Meier ◽  
Felix Gremse ◽  
Johannes Kleinheinz ◽  
...  

The aim of this study was to assess trabecular bone morphology via magnetic-resonance imaging (MRI) using microcomputed tomography (µCT) as the control group. Porcine bone samples were scanned with T1-weighted turbo spin echo sequence imaging, using TR 25 ms, TE 3.5 ms, FOV 100 × 100 × 90, voxel size 0.22 × 0.22 × 0.50 mm, and scan time of 11:18. µCT was used as the control group with 80 kV, 125 mA, and a voxel size of 16 µm. The trabecular bone was segmented on the basis of a reference threshold value and morphological parameters. Bone volume (BV), Bone-volume fraction (BvTv), Bone specific surface (BsBv), trabecular thickness (TbTh), and trabecular separation (TbSp) were evaluated. Paired t-test and Pearson correlation test were performed at p = 0.05. MRI overestimated BV, BvTv, TbTh, and TbSp values. BsBv was the only parameter that was underestimated by MRI. High statistical correlation (r = 0.826; p < 0.05) was found for BV measurements. Within the limitations of this study, MRI overestimated trabecular bone parameters, but with a statistically significant fixed linear offset.


2002 ◽  
Vol 35 (8) ◽  
pp. 1091-1099 ◽  
Author(s):  
Laurent Pothuaud ◽  
Bert Van Rietbergen ◽  
Lis Mosekilde ◽  
Olivier Beuf ◽  
Pierre Levitz ◽  
...  

2014 ◽  
Vol 6;17 (6;12) ◽  
pp. E737-E745
Author(s):  
Kyung-Hoon Kim

Background: Polymethyl methacrylate (PMMA) bone cement is widely used for osteoplasty. However, previous studies have demonstrated the adverse effects of PMMA due to its excessive stiffness and heat production. Recently, calcium phosphate cement (CPC) that overcomes those negative effects has been successfully applied in osteoplasty. The potential problem of CPC is markedly less initial stiffness. It leads to progressive, repeated collapse in the treated vertebra before CPC has been replaced by new bone that would provide substantial improvement in compressive strength and stiffness. The activated platelets in platelet-rich plasma (PRP) release a high concentration of growth factors which play an important role in bone healing. Objective: To investigate whether PRP could accelerate the osteoconduction of CPC and enhance the bone strength of the treated vertebra in an animal model. Study Design: Controlled animal study. Setting: Laboratory animal study, Methods: Thirty-two female Sprague-Dawley rats were ovariectomized at 8 weeks of age. After 3 months, they were randomly divided into 4 groups and received cement augmentation in the fifth caudal spine with different filler materials; sham-operated rats (S), PMMA (P), CPC (C), and CPC + PRP (CP). Bone mineral density (BMD) and trabecular type-associated morphological parameters, including trabecular bone volume fraction and trabecular thickness in the augmented caudal spine, were evaluated by micro-computed tomography (mirco-CT) 2 weeks after the cementoplasty. Histological analysis was also performed to compare the bone regeneration. Results: The trabecular bone volume fraction in the CP group was significantly greater than those of all the other groups. Trabecular thickness was higher in the CP group than the S and P groups. This augmented trabecular structure in the CP group accordingly showed higher BMD. Histological evaluations showed significantly more bone regeneration in the CP group. Limitations: There has been a concern that the effect of PRP would be dependent on the species, and might show different results in humans. Baseline values of micro-CT analysis were not measured, which could have provided exact evidence of the changes in trabecular microarchitecture parameters and cement resorption profiles. Finally, caudal vertebrae with filler materials used in biological study should have been compared by their mechanical properties using biomechanical evaluations for a more coherent study, which was not possible due to technical problems. Conclusions: Incorporating PRP into CPC could accelerate osteoconduction in the augmented vertebra leading to improvement of trabecular bone microarchitecture and BMD in rats. Key words: Bone mineral density, calcium phosphates, cementoplasty, histology, osteoconduction, osteoporosis, platelet-rich plasma, polymethyl methacrylate, vertebra


2000 ◽  
Author(s):  
Mark J. Eichler ◽  
Chi Hyun Kim ◽  
Ralph Müller ◽  
X. Edward Guo

Abstract Age-related bone fractures are mostly influenced by trabecular bone sites. Trabecular bone constantly adapts its bone volume fraction (BV/TV) and orientation, and thus its mechanical properties, to mechanical usage. Therefore, understanding the trabecular bone adaptation process and its consequences will contribute to the better understanding of the etiology of age-related fractures. Micro-computed tomography (micro-CT) is a relatively new method to quantify the complex three-dimensional (3D) trabecular bone architecture [1,2]. Finite element computational studies can be performed on these 3D microstructural images by converting each image voxel into an element [3,4,5]. Image thresholding techniques to segment bone voxels from bone marrow voxels have a major impact on the results of these models. However, the influence of different types of thresholding techniques on the mechanical properties of bone has not been examined carefully.


Sign in / Sign up

Export Citation Format

Share Document