Improvement of Fatigue Strength of Maraging Steel by Shot Peening

2007 ◽  
Vol 348-349 ◽  
pp. 537-540
Author(s):  
Norio Kawagoishi ◽  
Takanori Nagano ◽  
M. Moriyama ◽  
Eiji Kondo

Rotating bending fatigue tests up to 108 cycles were carried out to investigate the effects of shot peening on the fatigue strength and the fracture mechanism in an 18 % Ni maraging steel by using shot particles of various sizes or hardness. Fatigue strength was increased markedly by shot peening in the wide region of fatigue life. The S-N curves showed duplex S-N properties because of the transition of fracture origin from the specimen surface in the short life region to the subsurface in the long life one. Double shot peening by using super-hard fine particles was effective to improve the fatigue strength for surface fracture, though the fatigue strength for an internal fracture was hardly influenced. These results were discussed from the points of view of effects of surface roughness, residual stress and work hardening on the fatigue strength.

2002 ◽  
Vol 124 (2) ◽  
pp. 135-139 ◽  
Author(s):  
Hitoshi Soyama ◽  
Kenichi Saito ◽  
Masumi Saka

Cavitation impact, which normally produces severe damage in hydraulic machinery, can be used to modify surfaces in the same way as shot peening. Cavitation impact enables the surface of a material to be peened without the use of shot, thus it is called cavitation shotless peening. As there are no solid body collisions occurring in this peening process, the roughness of the peened surface should be less than that produced by shot peening. This characteristic makes it suitable for peening soft metals. In order to demonstrate the improvement of the fatigue strength of aluminum alloy by this process, specimens were subjected to the process, and then tested in a rotating bending fatigue test. Cavitation impacts were produced and controlled by using a submerged high speed water jet with cavitation, i.e., a cavitating jet. It was revealed that the fatigue strength of an aluminum alloy specimen treated by this peening process was 50% stronger than that of a specimen without peening.


2009 ◽  
Vol 417-418 ◽  
pp. 205-208 ◽  
Author(s):  
Kazuhiro Morino ◽  
Norio Kawagoishi ◽  
K. Yamane ◽  
K. Fukada

In order to investigate the effect of nitriding on the crack initiation and propagation behavior of Ni-base super alloy, Alloy 718, rotating bending fatigue tests were carried out until 108 cycles at room temperature. By nitriding at 500°C for 12h, compound layer of about 5μm in thickness was formed and the initiation of a fatigue crack was strongly suppressed causing the increase in fatigue strength. A crack initiated in brittle manner at the compound layer in all of fractures. However the crack propagated in ductile manner controlled by the property of the base alloy. That is, there is no or little influence of nitriding on the crack growth rate of the alloy.


1969 ◽  
Vol 11 (4) ◽  
pp. 432-443 ◽  
Author(s):  
P. F. Bray

Rotating bending fatigue tests on En 40B steel gave a fatigue limit for surface failure of 30·5 tonf/in2. With nitrided test-pieces sub-surface failures were produced and, with no allowance being made for residual stresses, a fatigue limit of 34·5 tonf/in2 was obtained for sub-surface failure. In the absence of residual stresses this fatigue limit would probably have been higher.


2008 ◽  
Vol 385-387 ◽  
pp. 113-116
Author(s):  
M. Miyazono ◽  
Norio Kawagoishi ◽  
Qing Yuan Wang ◽  
Eiji Kondo ◽  
Takanori Nagano

Rotating bending fatigue tests were carried out for maraging steels with different grain size in moist air in order to investigate the effects of humidity, grain size and reversion austenite on fatigue strength of the steel. Fatigue strength was decreased by humidity, and the decrease in fatigue strength was large in larger grain sized steel. Both of the initiation and propagation of a crack were promoted by humidity. Many cracks initiated at the specimen surface and intergranular cracks were observed at specimen surface and on fracture surface when humidity was high. The decrease in fatigue strength by humidity was suppressed by formation of reversion austenite.


2009 ◽  
Vol 417-418 ◽  
pp. 373-376
Author(s):  
T. Fukudome ◽  
Norio Kawagoishi ◽  
K. Kariya

Ultrasonic and rotating bending fatigue tests were carried out using plain specimens and specimens with a small blind hole for an extruded and age-hardened Al alloy 7075-T6 in different environments in order to investigate the effect of humidity on fatigue strength and fracture mechanism. Fatigue strength was decreased by high humidity under both tests. The effect of humidity on fatigue strength was larger in ultrasonic fatigue. The humidity affected both of crack initiation and propagation processes. Crack propagated in tensile mode then changed to shear mode macroscopically in all environments under ultrasonic fatigue, though it was only in tensile mode under rotating bending fatigue. These differences in fracture mechanism related to the difference in environmental effect on fatigue strength in both tests.


2009 ◽  
Vol 417-418 ◽  
pp. 209-212
Author(s):  
K. Yamane ◽  
Norio Kawagoishi ◽  
Kazuhiro Morino ◽  
K. Fukada

Ultrasonic and rotating bending fatigue tests were carried out for aged and nitrided Ni-base super alloys to investigate the effects of loading frequency and nitriding on fatigue strength. Loading frequencies were 19.5 kHz under ultrasonic and 50 Hz under rotating bending, respectively. Fatigue strength under ultrasonic was higher than that under rotating bending in both alloys. Moreover, in both tests, fatigue strength was improved by nitriding. The increase in fatigue strength by nitriding was large in ultrasonic fatigue. These results were discussed through the successive observation of fatigue process at specimen surface and fracture surface observation.


Sign in / Sign up

Export Citation Format

Share Document