Clinical evaluation of noninvasive monitoring of oxygen saturation in critically ill patients

1998 ◽  
Vol 7 (5) ◽  
pp. 370-373 ◽  
Author(s):  
P Smatlak ◽  
AR Knebel

OBJECTIVE: To examine the effect of abnormal cardiac index on the accuracy of measurement of oxygen saturation by pulse oximetry. METHODS: Forty-six patients (mean age, 49 years) in a 9-bed medical ICU were studied. Measurements of oxygen saturation obtained with pulse oximeters and with a functional cooximeter were collected at baseline and 4, 8, 16, 24, 32, 40, and 48 hours later. Hemodynamic and cardiopulmonary parameters were recorded. RESULTS: The Bland-Altman technique yielded upper and lower limits of agreement of 2.53% and -7.11%. Most (95.7%) of the differences between the measurements of oxygen saturation obtained with the 2 methods were within these limits, although some of these differences may be clinically unacceptable. The bias was -2.29%, and the precision was 2.41%. The clinical conditions associated with inaccurate tracking of saturation by pulse oximetry across the range of actual arterial oxygen saturation values were abnormal cardiac index, partial pressure of carbon dioxide, heart rate, and pulmonary capillary wedge pressure. CONCLUSIONS: In patients with abnormal cardiac index, the pulse oximeter measurements exceeded the actual oxygen saturation by up to 7%. Pending prospective studies, clinicians should be aware that when certain cardiopulmonary parameters are abnormal, the margin of error in measurements of oxygen saturation obtained with a pulse oximeter may be greater than when those parameters are normal.

Author(s):  
Aslıhan Gürün Kaya ◽  
Miraç Öz ◽  
İREM AKDEMİR KALKAN ◽  
Ezgi Gülten ◽  
güle AYDIN ◽  
...  

Introduction: Guidelines recommend using a pulse oximeter rather than arterial blood gas (ABG) for COVID-19 patients. However, significant differences can be observed between oxygen saturation measured by pulse oximetry (SpO2) and arterial oxygen saturation (SaO2) in some clinical conditions. We aimed to assess the reliability of pulse oximeter in patients with COVID-19 Methods: We retrospectively reviewed ABG analyses and SpO2 levels measured simultaneously with ABG in patients hospitalized in COVID-19 wards. Results: We categorized total 117 patients into two groups; in whom the difference between SpO2 and SaO2 was 4% (acceptable difference) and >4% (large difference). Large difference group exhibited higher neutrophil count, C-reactive protein, ferritin, fibrinogen, D-dimer and lower lymphocyte count. Multivariate analyses revealed that increased fibrinogen, increased ferritin and decreased lymphocyte count were independent risk factors for large difference between SpO2 and SaO2. The total study group demonstrated the negative bias of 4.02% with the limits of agreement of −9.22% to 1.17%. The bias became significantly higher in patients with higher ferritin, fibrinogen levels and lower lymphocyte count. Conclusion: Pulse oximeters may not be sufficient to assess actual oxygen saturation especially in COVID-19 patients with high ferritin and fibrinogen levels and low lymphocyte count low SpO2 measurements.


2021 ◽  
Vol 16 ◽  
Author(s):  
Alaa Thabet Hassan ◽  
Soher Mostafa Ahmed ◽  
Azza Salah AbdelHaffeez ◽  
Sherif A.A. Mohamed

Background: Despite its wide use in clinical practice, few studies had assessed the role of pulse oximetry in patients with heart failure. We aimed to evaluate the accuracy and precision of the pulse oximeter in patients with heart failure and to determine this accuracy at three different sensor locations.Methods: Comparison of pulse oximetry reading (SpO2) with arterial oxygen saturation (SaO2) was reported in 3 groups of patients with heart failure (HF); those with ejection fraction (EF) >40%, those with EF <40%, and those with acute HF (AHF) with ST and non-ST segment elevation acute myocardial infarction (STEMI and non-STEMI).Results: A total of 235 patients and 90 control subjects were enrolled. There were significant differences in O2 saturation between control and patients’ groups when O2 saturation is measured at the finger and toe, but not the ear probes; p=0.029, p=0.049, and 0.051, respectively. In HF with EF>40% and AHF with O2 saturations >90%, finger oximetry is the most accurate and reliable, while in HF with EF<40% and in patients with AHF with O2 saturations <90%, ear oximetry is the most accurate.Conclusion: Pulse oximetry is a reliable tool in assessing oxygen saturation in patients with heart failure of different severity. In HF with EF>40% and in AHF with O2 saturations >90%, finger oximetry is the most accurate and reliable, while in HF with EF<40% and in patients with AHF with O2 saturations <90%, ear oximetry is the most accurate. Further studies are warranted.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shinshu Katayama ◽  
Jun Shima ◽  
Ken Tonai ◽  
Kansuke Koyama ◽  
Shin Nunomiya

AbstractRecently, maintaining a certain oxygen saturation measured by pulse oximetry (SpO2) range in mechanically ventilated patients was recommended; attaching the INTELLiVENT-ASV to ventilators might be beneficial. We evaluated the SpO2 measurement accuracy of a Nihon Kohden and a Masimo monitor compared to actual arterial oxygen saturation (SaO2). SpO2 was simultaneously measured by a Nihon Kohden and Masimo monitor in patients consecutively admitted to a general intensive care unit and mechanically ventilated. Bland–Altman plots were used to compare measured SpO2 with actual SaO2. One hundred mechanically ventilated patients and 1497 arterial blood gas results were reviewed. Mean SaO2 values, Nihon Kohden SpO2 measurements, and Masimo SpO2 measurements were 95.7%, 96.4%, and 96.9%, respectively. The Nihon Kohden SpO2 measurements were less biased than Masimo measurements; their precision was not significantly different. Nihon Kohden and Masimo SpO2 measurements were not significantly different in the “SaO2 < 94%” group (P = 0.083). In the “94% ≤ SaO2 < 98%” and “SaO2 ≥ 98%” groups, there were significant differences between the Nihon Kohden and Masimo SpO2 measurements (P < 0.0001; P = 0.006; respectively). Therefore, when using automatically controlling oxygenation with INTELLiVENT-ASV in mechanically ventilated patients, the Nihon Kohden SpO2 sensor is preferable.Trial registration UMIN000027671. Registered 7 June 2017.


PEDIATRICS ◽  
1987 ◽  
Vol 79 (4) ◽  
pp. 524-528
Author(s):  
Michael S. Jennis ◽  
Joyce L. Peabody

Continuous monitoring of oxygenation in sick newborns is vitally important. However, transcutaneous Po2 measurements have a number of limiations. Therefore, we report the use of the pulse oximeter for arterial oxygen saturation (Sao2) determination in 26 infants (birth weights 725 to 4,000 g, gestational ages 24 to 40 weeks, and postnatal ages one to 49 days). Fetal hemoglobin determinations were made on all infants and were repeated following transfusion. Sao2, readings from the pulse oximeter were compared with the Sao2 measured in vitro on simultaneously obtained arterial blood samples. The linear regression equation for 177 paired measurements was: y = 0.7x + 27.2; r = .9. However, the differences between measured Sao2 and the pulse oximeter Sao2 were significantly greater in samples with &gt; 50% fetal hemoglobin when compared with samples with &lt; 25% fetal hemoglobin (P &lt; .001). The pulse oximeter was easy to use, recorded trends in oxygenation instantaneously, and was not associated with skin injury. We conclude that pulse oximetry is a reliable technique for the continuous, noninvasive monitoring of oxygenation in newborn infants.


2008 ◽  
Vol 10 (03) ◽  
pp. 250-254 ◽  
Author(s):  
Andrew Harris ◽  
Michael Sendak ◽  
D. Chung ◽  
Charles Richardson

2016 ◽  
Vol 29 (5) ◽  
pp. 343
Author(s):  
Miguel Pinto da Costa ◽  
Henrique Pimenta Coelho

<p>The authors present a case of a 60-year-old male patient, previously diagnosed with B-cell chronic lymphocytic leukemia, who was admitted to the Emergency Room with dyspnea. The initial evaluation revealed severe anemia (Hgb = 5.0 g/dL) with hyperleukocytosis (800.000/µL), nearly all of the cells being mature lymphocytes, a normal chest X-ray and a low arterial oxygen saturation (89%; pulse oximetry). After red blood cell transfusion, Hgb values rose (9.0 g/dL) and there was a complete reversion of the dyspnea. Yet, subsequent arterial blood gas analysis, without the administration of supplemental oxygen, systematically revealed very low oxygen saturation values (~ 46%), which was inconsistent with the patient’s clinical state and his pulse oximetry values (~ 87%), and these values were not corrected by the administration of oxygen via non-rebreather mask. The investigation performed allowed to establish the diagnosis of oxygen leukocyte larceny, a phenomenon which conceals the true oxygen saturation due to peripheral consumption by leukocytes.</p>