scholarly journals Relations between Long-term Glycemic Control and Postoperative Wound and Infectious Complications after Total Knee Arthroplasty in Type 2 Diabetics

2013 ◽  
Vol 5 (2) ◽  
pp. 118 ◽  
Author(s):  
Hyuk-Soo Han ◽  
Seung-Baik Kang
Author(s):  
Jason D. Tegethoff ◽  
Rafael Walker-Santiago ◽  
William M. Ralston ◽  
James A. Keeney

AbstractIsolated polyethylene liner exchange (IPLE) is infrequently selected as a treatment approach for patients with primary total knee arthroplasty (TKA) prosthetic joint instability. Potential advantages of less immediate surgical morbidity, faster recovery, and lower procedural cost need to be measured against reoperation and re-revision risk. Few published studies have directly compared IPLE with combined tibial and femoral component revision to treat patients with primary TKA instability. After obtaining institutional review board (IRB) approval, we performed a retrospective comparison of 20 patients treated with IPLE and 126 patients treated with tibial and femoral component revisions at a single institution between 2011 and 2018. Patient demographic characteristics, medical comorbidities, time to initial revision TKA, and reoperation (90 days, <2 years, and >2 years) were assessed using paired Student's t-test or Fisher's exact test with a p-value <0.01 used to determine significance. Patients undergoing IPLE were more likely to undergo reoperation (60.0 vs. 17.5%, p = 0.001), component revision surgery (45.0 vs. 8.7%, p = 0.002), and component revision within 2 years (30.0 vs. 1.6%, p < 0.0001). Differences in 90-day reoperation (p = 0.14) and revision >2 years (p = 0.19) were not significant. Reoperation for instability (30.0 vs. 4.0%, p < 0.001) and infection (20.0 vs. 1.6%, p < 0.01) were both higher in the IPLE group. IPLE does not provide consistent benefits for patients undergoing TKA revision for instability. Considerations for lower immediate postoperative morbidity and cost need to be carefully measured against long-term consequences of reoperation, delayed component revision, and increased long-term costs of multiple surgical procedures. This is a level III, case–control study.


Author(s):  
Francisco Antonio Miralles-Muñoz ◽  
Marta Rubio-Morales ◽  
Laiz Bello-Tejada ◽  
Santiago González-Parreño ◽  
Alejandro Lizaur-Utrilla ◽  
...  

2013 ◽  
Vol 38 (4) ◽  
pp. 747-752 ◽  
Author(s):  
Matthias Bachmann ◽  
Lilianna Bolliger ◽  
Thomas Ilchmann ◽  
Martin Clauss

Coatings ◽  
2020 ◽  
Vol 10 (5) ◽  
pp. 442 ◽  
Author(s):  
Georg Hauer ◽  
Lukas Leitner ◽  
Marc C. Ackerl ◽  
Sebastian Klim ◽  
Ines Vielgut ◽  
...  

Background: The impact of titanium nitride (TiN) coating on implant components is controversial. TiN coating is proposed as having superior biomechanical properties compared to conventional cobalt-chromium (CoCr) alloy. This study compared long-term clinical data as well as meteoro-sensitivity in patients who underwent total knee arthroplasty (TKA), with either CoCr alloy or TiN coating. Methods: In this retrospective observational study, the clinically approved cemented “low contact stress” (LCS) TKA with conventional CoCr coating, was compared to un-cemented TiN-coated “advanced coated system” (ACS) TKA. Propensity score matching identified comparable patients based on their characteristics in a one-to-one ratio using the nearest-neighbor method. The final cohort comprised 260 knees in each cohort, with a mean follow-up of 10.1 ± 1.0 years for ACS patients and 14.9 ± 3.0 years for the LCS group. Physical examinations, meteoro-sensitivity, and knee scoring were assessed. Results: The clinical and functional Knee Society Score (KSS) (82.6 vs. 70.8; p < 0.001 and 61.9 vs. 71.1; p = 0.011), the postoperative Visual Analogue Scale (VAS) (2.9 vs. 1.4; p = 0.002), and the postoperative Tegner Score (2.6 vs. 2.2; p = 0.001) showed significant intergroup differences. The postoperative Western Ontario & McMaster Universities Osteoarthritis Index (WOMAC) was similar (79.9 vs. 81.3; p = 0.453) between groups. Meteoro-sensitivity of the artificial joint was significantly more prevalent in the ACS patient cohort (56% vs. 23%; p < 0.001). Conclusion: This study suggests that TiN coating does not provide improved clinical outcomes in this patient cohort after a long-term follow-up. Interestingly, sensitivity to weather changes were more correlated with un-cemented ACS implants.


Sign in / Sign up

Export Citation Format

Share Document