Posterior Surgery of Neurologically Compromised Osteoporotic Kyphosis - Posterolateral Decompression and Stabilization using Titanium Mesh -

2008 ◽  
Vol 43 (6) ◽  
pp. 791
Author(s):  
Jung-Hee Lee ◽  
Ki-Tack Kim ◽  
Kyung-Soo Suk ◽  
Sang-Hun Lee ◽  
Dae-Woo Hwang ◽  
...  
Skull Base ◽  
2007 ◽  
Vol 17 (S 1) ◽  
Author(s):  
Martin Blaha ◽  
Michal Tichy ◽  
Juraj Schwab ◽  
Lubomír Pekař ◽  
Jiří Kozák

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yuhang Wang ◽  
Yi Zhan ◽  
Huiming Yang ◽  
Hua Guo ◽  
Haiping Zhang ◽  
...  

AbstractFusion with a titanium mesh cage (TMC) has become popular as a conventional method after cervical anterior corpectomy, but postoperative TMC subsidence has often been reported in the literature. We designed a novel anatomic cervical TMC to reduce the postoperative subsidence rate. According to the test process specified in the American Society of Testing Materials (ASTM) F2267 standard, three-dimensional finite element analysis was used to compare the anti-subsidence characteristics of a traditional TMC (TTMC) and novel TMC (NTMC). Through analysis, the relative propensity values of a device to subside (Kp) of the TTMC and NTMC were 665.5 N/mm and 1007.2 N/mm, respectively. A higher Kp measurement is generally expected to indicate that the device is more resistant to subsidence into a vertebral body. The results showed that the novel anatomic titanium mesh cage (NTMC) significantly improved the anti-subsidence performance after anterior cervical corpectomy and fusion (ACCF), which was approximately 51.3% higher than that of the traditional titanium mesh cage.


2021 ◽  
Vol 10 (9) ◽  
pp. 1922
Author(s):  
Carlos Navarro Cuéllar ◽  
Manuel Tousidonis Rial ◽  
Raúl Antúnez-Conde ◽  
Santiago Ochandiano Caicoya ◽  
Ignacio Navarro Cuéllar ◽  
...  

Mandibular reconstruction with fibula flap shows a 3D discrepancy between the fibula and the remnant mandible. Eight patients underwent three-dimensional reconstruction of the fibula flap with iliac crest graft and dental implants through virtual surgical planning (VSP), stereolitographic models (STL) and CAD/CAM titanium mesh. Vertical ridge augmentation and horizontal dimensions of the fibula, peri-implant bone resorption of the iliac crest graft, implant success rate and functional and aesthetic results were evaluated. Vertical reconstruction ranged from 13.4 mm to 10.1 mm, with an average of 12.22 mm. Iliac crest graft and titanium mesh were able to preserve the width of the fibula, which ranged from 8.9 mm to 11.7 mm, with an average of 10.1 mm. A total of 38 implants were placed in the new mandible, with an average of 4.75 ± 0.4 implants per patient and an osseointegration success rate of 94.7%. Two implants were lost during the osseointegration period (5.3%). Bone resorption was measured as peri-implant bone resorption at the mesial and distal level of each implant, with a variation between 0.5 mm and 2.4 mm, and with a mean of 1.43 mm. All patients were rehabilitated with a fixed implant prosthesis with good aesthetic and functional results.


2019 ◽  
Vol 30 (8) ◽  
pp. 2341-2344
Author(s):  
Anil Madaree ◽  
Nondabula Moyeni ◽  
Petrus Andries Jacobus Le Roux ◽  
Trishan Pillay
Keyword(s):  

Medicina ◽  
2021 ◽  
Vol 57 (1) ◽  
pp. 60
Author(s):  
Daniele De Santis ◽  
Federico Gelpi ◽  
Giuseppe Verlato ◽  
Umberto Luciano ◽  
Lorena Torroni ◽  
...  

Background and Objective: Guided bone regeneration allows new bone formation in anatomical sites showing defects preventing implant rehabilitation. Material and Methods: The present case series reported the outcomes of five patients treated with customized titanium meshes manufactured with a digital workflow for achieving bone regeneration at future implant sites. A significant gain in both width and thickness was achieved for all patients. Results: From a radiographic point of view (CBTC), satisfactory results were reached both in horizontal and vertical defects. An average horizontal gain of 3.6 ± 0.8 mm and a vertical gain of 5.2 ± 1.1 mm. Conclusions: The findings from this study suggest that customized titanium meshes represent a valid method to pursue guided bone regeneration in horizontal, vertical or combined defects. Particular attention must be paid by the surgeon in the packaging of the flap according to a correct method called the “poncho” technique in order to reduce the most frequent complication that is the exposure of the mesh even if a partial exposure of one mesh does not compromise the final outcome of both the reconstruction and the healing of the implants.


Sign in / Sign up

Export Citation Format

Share Document