A Study about Size and Shape of Bipolar Radiofrequency Lesions

2008 ◽  
Vol 54 (2) ◽  
pp. 197 ◽  
Author(s):  
Eun-mi Choi ◽  
Keun-Man Shin ◽  
Sung-keun Nam ◽  
Il-Young Cheong
2012 ◽  
Vol 25 (3) ◽  
pp. 151 ◽  
Author(s):  
Sang Soo Kang ◽  
Jung Chan Park ◽  
Young Jun Yoon ◽  
Keun Man Shin

2000 ◽  
Vol 39 (2) ◽  
pp. 260 ◽  
Author(s):  
Kee Heon Lee ◽  
Seon Hye Yun ◽  
Hyun Ju Kim ◽  
Bae Hee Jung ◽  
So Young Lim ◽  
...  

2005 ◽  
Vol 30 (4) ◽  
pp. 335-338
Author(s):  
Carlos A. Pino ◽  
Mark A. Hoeft ◽  
Craig Hofsess ◽  
James P. Rathmell

Author(s):  
H.J.G. Gundersen

Previously, all stereological estimation of particle number and sizes were based on models and notoriously gave biased results, were very inefficient to use and difficult to justify. For all references to old methods and a direct comparison with unbiased methods see recent reviews.The publication in 1984 of the DISECTOR, the first unbiased stereological probe for sampling and counting 3—D objects irrespective of their size and shape, signalled the new era in stereology — and give rise to a number of remarkably simple and efficient techniques based on its distinct property: It is the only known way to obtain an unbiased sample of 3-D objects (cells, organelles, etc). The principle is simple: within a 2-D unbiased frame count or sample only cells which are not hit by a parallel plane at a known, small distance h.The area of the frame and h must be known, which might sometimes in itself be a problem, albeit usually a small one. A more severe problem may arise because these constants are known at the scale of the fixed, embedded and sectioned tissue which is often shrunken considerably.


Author(s):  
C J R Sheppard

The confocal microscope is now widely used in both biomedical and industrial applications for imaging, in three dimensions, objects with appreciable depth. There are now a range of different microscopes on the market, which have adopted a variety of different designs. The aim of this paper is to explore the effects on imaging performance of design parameters including the method of scanning, the type of detector, and the size and shape of the confocal aperture.It is becoming apparent that there is no such thing as an ideal confocal microscope: all systems have limitations and the best compromise depends on what the microscope is used for and how it is used. The most important compromise at present is between image quality and speed of scanning, which is particularly apparent when imaging with very weak signals. If great speed is not of importance, then the fundamental limitation for fluorescence imaging is the detection of sufficient numbers of photons before the fluorochrome bleaches.


VASA ◽  
2011 ◽  
Vol 40 (3) ◽  
pp. 235-240 ◽  
Author(s):  
Krnic ◽  
Sucic

Background: The aim of this study is to report our results in main stem vein closure using the bipolar radiofrequency induced thermotherapy (RFITT) system and the 1064nm Nd:Yag laser. Patients and methods: 44 incompetent main stem veins (37 great saphenous veins, one lesser saphenous vein, and 6 anterior accessory saphenous veins) in 29 patients were treated using RFITT. 53 incompetent main stem veins (45 great saphenous veins, 4 lesser saphenous veins, and 4 anterior accessory saphenous veins) in 43 patients were treated endovenously with 1064 nm Nd:Yag laser. All patients underwent postoperative duplex scanning within a month after procedure, as well as a short interview regarding postoperative discomfort. Results: In main stem veins treated with RFITT, the success rate within the first month was 86,4 % (38 out of 44 veins). Complete failure rate was 13,6 % (6 out of 44 veins). In 53 main stem veins treated by 1064 nm Nd:Yag laser, the success rate was 100 %, consisting of 98,1 % complete success (52/53 veins), and 1,9 % partial success (1/53 veins). None of the patients treated with RFITT experienced postoperative adverse effects, whereas 13/43 (30,2 %) patients treated with laser had to use oral analgesics after the treatment, and 21/43 (48,8 %) patients reported transient skin changes, such as bruising or skin redness. Conclusions: RFITT system was fairly efficient in the short term for closure of main trunk veins, whereas longer term results are still scarce. Postoperative side effects of RFITT were minimal. 1064nm Nd:Yag laser, according to short term results, proved to be very effective for main stem vein closure. Postoperative side effects related to 1064 nm Nd:Yag endovenous laser treatment proved to be minor, transient, and acceptable.


1984 ◽  
Vol 45 (C9) ◽  
pp. C9-29-C9-37
Author(s):  
Vu Thien Binh ◽  
M. Drechsler
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document