The Closure Ordering of Nilpotent Orbits of the Complex Symmetric Pair (SOp+q, SOp × SOq)

2003 ◽  
Vol 55 (6) ◽  
pp. 1155-1190 ◽  
Author(s):  
Dragomir Ž. Ðoković ◽  
Michael Litvinov

AbstractThe main problem that is solved in this paper has the following simple formulation (which is not used in its solution). The group K = Op(C) × Oq(C) acts on the space Mp, q of p × q complex matrices by (a; b) · x = axb–1, and so does its identity component K0 = SOp(C)×SOq(C). A K-orbit (or K0-orbit) in Mp,q is said to be nilpotent if its closure contains the zero matrix. The closure, , of a nilpotent K-orbit (resp. K0-orbit) in Mp,q is a union of and some nilpotent K-orbits (resp. K0-orbits) of smaller dimensions. The description of the closure of nilpotent K-orbits has been known for some time, but not so for the nilpotent K0-orbits. A conjecture describing the closure of nilpotent K0-orbits was proposed in [11] and verièd when min(p, q) ≤ 7. In this paper we prove the conjecture. The proof is based on a study of two prehomogeneous vector spaces attached to and determination of the basic relative invariants of these spaces.The above problem is equivalent to the problem of describing the closure of nilpotent orbits in the real Lie algebra so(p, q) under the adjoint action of the identity component of the real orthogonal group O(p, q).

2020 ◽  
Vol 42 (2) ◽  
pp. 68-75
Author(s):  
V.G. Demchenko ◽  
А.S. Тrubachev ◽  
A.V. Konyk

Worked out methodology of determination of the tensely-deformed state of elements of mobile heat storage of capacity type, that works in the real terms of temperature and power stress on allows to estimate influence of potential energy on resilient deformation that influences on reliability of construction and to give recommendations on planning of tank (capacities) of accumulator. For determination possibly of possible tension of construction of accumulator kinematics maximum terms were certain. As a tank of accumulator shows a soba the difficult geometrical system, the mathematical model of calculation of coefficient of polynomial and decision of task of minimization of functional was improved for determination of tension for Міzеs taking into account the real geometry of equipment. Conducted quantitative estimation of the tensely-deformed state of the union coupling, corps and bottom of thermal accumulator and the resource of work of these constructions is appraised. Thus admissible tension folds 225 МРа.


Author(s):  
Kamil Krasuski ◽  
Stepan Savchuk

This paper presents results of research concerning determination of the GPS reference station coordinates located on the grounds of an EPDE airport in Deblin. The study uses a mathematical model of the PPP measurement technique in order to determine the coordinates of the reference station using the real GPS code-phase observations. The computations of the coordinates of the GPS reference station were carried out in numerical applications CSRS-PPP, APPS and GAPS. In this research was found that the accuracy of finding solutions to the XYZ geocentric coordinates of the reference station REF1 between solutions CSRS-PPP, APPS and GAPS ranges from 0.01m to 0.13m. In addition, the accuracy of determining the XYZ geocentric coordinates from the PPP method related to the GPS differential solution ranged from 0.01m to 0.11m.


1969 ◽  
Vol 17 (1) ◽  
pp. 71-79
Author(s):  
A.I. Golovanov

Experiments were made to determine the influence of size of soil sample, convection and water flow on the determination of thermal conductivity of soils using a thin needle (0.05 cm radius, 8.5 cm in length) as the heating element and copper cylinders for sample containers. For measurements during a period of 100 seconds the diameter of the sample must be at least 4 cm and to avoid any influence of convection measurements should not exceed 100 seconds. When heating elements are placed horizontally to measure simultaneously the thermal conductivity of different soil layers they should be placed at least 10 cm apart. Thermal conductivity measurements could be used to determine flow velocities of water in coarse sand samples provided that the real flow velocity was highev than 0.35 cm/ min. (Abstract retrieved from CAB Abstracts by CABI’s permission)


2021 ◽  
Vol 236 ◽  
pp. 02033
Author(s):  
Xiaoyan Ge ◽  
Qian Mo ◽  
Guofeng Wang ◽  
Yan Zhao ◽  
Yongyu Li ◽  
...  

Antimony (Sb) is a toxic and potentially carcinogenic metalloid element. The toxicity of Sb in the environment strongly relies on its speciation. It is necessary to investigate the speciation and content of antimony in soil in order to understand better the real risk associated with Sb in the environment. This study developed water bath heating and soaking-AFS methods to determine the available and carbonate antimony in soil. Through analysis and mutual verification experiments in three different laboratories, the repeatability and reproducibility in the precision experiment were less than 3.44, the average recovery rate was more than 98.1%. These methods were accurate, reproducible and effective for detecting the content of available and carbonate antimony in soil.


2017 ◽  
Vol 22 (2) ◽  
Author(s):  
EMILIAN MOȘNEGUȚU ◽  
VALENTIN NEDEFF ◽  
MIRELA PANAINTE-LEHĂDUȘ ◽  
NARCIS BÂRSAN ◽  
DANA CHIȚIMUȘ ◽  
...  

This article presents the methodology for determining the real values of kinematic indices which characterizes the mechanical separation of a mixture of solid particles. Mechanical separation of a mixture of solid-solid on surface provided with holes is the most common method of separation. To optimize equipment that performs this operation, both theoretical and practical characteristics are determined. Kinematic indices are part of the theoretical characteristics, helping to identify behavior of solid particles on a surface flat swing. Starting from an experimental batch, real values of the kinematic indices corresponding to up, down and sideways movement on the sieve were determined for the following types of real particles: grain, large grain beans, small grain beans and soybeans.


Author(s):  
Hideto Nakashima

AbstractIn this paper, we give necessary and sufficient conditions for a homogeneous cone Ω to be symmetric in two ways. One is by using the multiplier matrix of Ω, and the other is in terms of the basic relative invariants of Ω. In the latter approach, we need to show that the real parts of certain meromorphic rational functions obtained by the basic relative invariants are always positive on the tube domains over Ω. This is a generalization of a result of Ishi and Nomura [Math. Z. 259 (2008), 604–674].


2010 ◽  
Vol 23 (5) ◽  
pp. 543-548 ◽  
Author(s):  
Lan-lan Fang ◽  
Qian Tao ◽  
Ming-fang Li ◽  
Ling-wen Liao ◽  
Dong Chen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document