scholarly journals Design and Performances of Implantable CPW Fed Apollian Shaped Antenna at 2.45 GHz ISM Band for Biomedical Applications

2015 ◽  
Vol 16 (5) ◽  
pp. 250-253 ◽  
Author(s):  
S. Ashok Kumar ◽  
J. Navin Sankar ◽  
D. Dileepan ◽  
T. Shanmuganantham
2013 ◽  
Vol 6 (2) ◽  
pp. 167-172 ◽  
Author(s):  
Srinivasan Ashok Kumar ◽  
Thangavelu Shanmuganantham

A novel coplanar waveguide fed Industrial, Scientific, and Medical (ISM) band implantable crossed-type triangular slot antenna is proposed for biomedical applications. The antenna operates at the center frequency of 2450 MHz, which is in ISM band, to support GHz wideband communication for high-data rate implantable biomedical application. The size of the antenna is 78 mm3 (10 mm × 12 mm × 0.65 mm). The simulated and measured bandwidths are 7.9 and 8.2% at the resonant frequency of 2.45 GHz. The specific absorption rate distribution induced by the implantable antenna inside a human body tissue model is evaluated. The communication between the implanted antenna and external device is also examined. The proposed antenna has substantial merits such as miniaturization, lower return loss, better impedance matching, and high gain over other implanted antennas.


Frequenz ◽  
2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Navneet Sharma ◽  
Anubhav Kumar ◽  
Asok De ◽  
Rakesh K. Jain

Abstract A compact, circularly polarized, CPW-fed antenna is proposed for wearable applications in ISM Band (5.8 GHz). The antenna is based on DGS, where the ground plane is responsible for impedance matching. The 10 dB impedance of the proposed antenna varies from 5.39 GHz to 5.94 GHz. The circular stub introduced in the ground plane mitigates the surface current and enriches the 3 dB axial ratio from 5.73 GHz to 5.92 GHz. Proposed antenna exhibits the LHCP and RHCP pattern of circular polarization, the antenna can effectively work for biomedical and wearable applications. The antenna is analyzed on the skin phantom model and the SAR value obtained is 1.218 W/kg, which is below the maximum permissible level. The proposed antenna is also used for the detection of breast tumors.


IEEE Access ◽  
2019 ◽  
Vol 7 ◽  
pp. 43547-43554 ◽  
Author(s):  
Kumar Naik Ketavath ◽  
Dattatreya Gopi ◽  
Sriram Sandhya Rani

Author(s):  
M Sujatha ◽  
B T P Madhav ◽  
V Prakhya ◽  
B Akhila ◽  
N Gowtham ◽  
...  

2021 ◽  
Author(s):  
Majedeh Seydi ◽  
Mohammad Sajjad Bayati

Abstract A rectangular meandering-microstrip patch antenna (RM-MPA) with shorting pin for implant antenna and biomedical applications at industrial, scientific, and medical (ISM) band is proposed. The rectangular patch has length of l =14 mm and width of w =9.4 mm. The substrate and superstrate are made of Rogers 3210 with dielectric constant equals 10.2. The RMMPA is placed between the substrate and superstrate dielectric layers whose same thickness equals 0.635 mm. The proposed antenna is fed by a 50-ohm coaxial probe, at the centre of the length and edge of the width of the patch. The input impedance of patch antenna varies with the patch geometry. Thus, the geometry of the patch changed to achieve impedance matching at ISM band. The rectangular patch divided to three sections along width for meandering. The resonance frequency is tuned by meandering each section. The proposed antenna is simulated in free space and skin phantom. Proposed antenna has efficiency of 90%, bandwidth 1.02%. Both radiation pattern and SAR are evaluated which SAR level is below the safety and satisfies SAR standards. Finally, the antenna is tested in minced meat and tissue liquid.


Frequenz ◽  
2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Kim Ho Yeap ◽  
Eileen Mei Foong Tan ◽  
Takefumi Hiraguri ◽  
Koon Chun Lai ◽  
Kazuhiro Hirasawa

Abstract We present the design of a compact tri-band adhesive planar antenna which operates as a gateway for biomedical applications. Operating in the Industrial, Scientific and Medical (ISM) band (2.4–2.5 GHz), the Institute of Electrical and Electronics Engineers (IEEE) 802.15.6 Wireless Body Area Network Ultra-Wide Band (WBAN UWB) (3.1–10.6 GHz) and the IEEE 802.11 Wireless Local Area Network or WLAN (WLAN) band (5.15–5.725 GHz), the antenna is useful in the context of body-signal monitoring. The ISM band is used for in-body communication with the implanted medical devices, whereas the WBAN and WLAN bands are for off-body communication with the base station and central medical server, respectively. We have designed our antenna to operate at 2.34/3.20/4.98 GHz. The simulation results show that the antenna has 10 dB bandwidths of 420 MHz (2.07–2.49 GHz), 90 MHz (3.16–3.25 GHz), and 460 MHz (4.76–5.22 GHz) to cover the ISM, WBAN, and WLAN bands, respectively. The proposed antenna is printed on a flexible Rogers RT/duroid 5880 epoxy substrate and it occupies a compact volume of 24 × 24 × 0.787 mm. The designed antenna is simulated using HFSS and the fabricated antenna is experimentally validated by adhering it to a human skin. The simulated and measured performance of the antenna confirms its omnidirectional radiation patterns and high return losses at the three resonant bands.


2020 ◽  
Vol 68 (3) ◽  
pp. 2399-2404 ◽  
Author(s):  
Zhan Xia ◽  
Hua Li ◽  
Zongze Lee ◽  
Shaoqiu Xiao ◽  
Wei Shao ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document