Effectiveness of a Laboratory-Scale Vertical Tower Static Chamber Steam Pasteurization Unit against Escherichia coli O157:H7, Salmonella Typhimurium, and Listeria innocua on Prerigor Beef Tissue†

2004 ◽  
Vol 67 (8) ◽  
pp. 1630-1633 ◽  
Author(s):  
DEANNA RETZLAFF ◽  
RANDALL PHEBUS ◽  
ABBEY NUTSCH ◽  
JAMES RIEMANN ◽  
CURTIS KASTNER ◽  
...  

A laboratory-scale vertical tower steam pasteurization unit was evaluated to determine the antimicrobial effectiveness of different exposure times (0, 3, 6, 12, and 15 s) and steam chamber temperatures (82.2, 87.8, 93.3, and 98.9°C) against pathogens (Escherichia coli O157:H7, Salmonella Typhimurium, and Listeria innocua) inoculated onto prerigor beef tissue. Samples were collected and microbiologically analyzed immediately before and after steam treatment to quantify the effectiveness of each time-temperature combination. The 0-s exposure at all chamber temperatures (cold water spray only, no steam treatment) was the experimental control and provided ≤0.3 log CFU/cm2 reductions. Chamber temperatures of 82.2 and 87.8°C were ineffective (P > 0.05) at all exposure times. At 93.3°C, significant reductions (>1.0 log CFU/cm2) were observed at exposure times of ≥6 s, with 15 s providing approximately 1 log cycle greater reductions than 12 s of exposure. The 98.9°C treatment was consistently the most effective, with exposure times of ≥9 s resulting in >3.5 log CFU/cm2 reductions for all pathogens.

1997 ◽  
Vol 60 (5) ◽  
pp. 476-484 ◽  
Author(s):  
RANDALL K. PHEBUS ◽  
ABBEY L. NUTSCH ◽  
DAVID E. SCHAFER ◽  
R. CRAIG WILSON ◽  
M. JAMES RIEMANN ◽  
...  

The effectiveness of a recently invented “steam pasteurization” (S) process in reducing pathogenic bacterial populations on surfaces of freshly slaughtered beef was determined and compared with that of other standard commercial methods including knife trimming (T), water washing (35°C; W), hot water/steam vacuum spot cleaning (V), and spraying with 2% vol/vol lactic acid (54°C, pH 2.25; L). These decontamination treatments were tested individually and in combinations. Cutaneus trunci muscles from freshly slaughtered steers were inoculated with feces containing Listeria monocytogenes Scott A, Escherichia coli OI57:H7, and Salmonella typhimurium over a predesignated meat surface area, resulting in initial populations of ca. 5 log CFU/cm2 of each pathogen. Tissue samples were excised from each portion before and after decontamination treatments, and mean population reductions were determined. Treatment combinations evaluated were the following (treatment designations within the abbreviations indicate the order of application): TW, TWS, WS, VW, VWS, TWLS, and VWLS. These combinations resulted in reductions ranging from 3.5 to 5.3 log CFU/cm2 in all three pathogen populations. The TW, TWS, WS, TWLS, and VWLS combinations were equally effective (P > 0.05), resulting in reductions ranging from 4.2 to 5.3 log CFU/cm2. When used individually, T, V, and S resulted in pathogen reductions ranging from 2.5 to 3.7 log CFU/cm2 Steam pasteurization consistently provided numerically greater pathogen reductions than T or V. Treatments T, V, and S were all more effective than W (which gave a reduction on the order of 1.0 log CFU/cm2). Steam pasteurization is an effective method for reducing pathogenic bacterial populations on surfaces of freshly slaughtered beef, with multiple decontamination procedures providing greatest overall reductions.


2012 ◽  
Vol 75 (9) ◽  
pp. 1611-1618 ◽  
Author(s):  
XUETONG FAN ◽  
KIMBERLY J. B. SOKORAI ◽  
JÜRGEN ENGEMANN ◽  
JOSHUA B. GURTLER ◽  
YANHONG LIU

A novel in-package ozonation device was evaluated for its efficacy in inactivating three microorganisms (viz., Listeria innocua, attenuated Salmonella Typhimurium, and Escherichia coli O157:H7) on tomatoes and for its effect on fruit quality. The device produced ozone inside sealed film bags, reaching a concentration of 1,000 ppm within 1 min of activation. The three bacterial cultures were inoculated onto either the smooth surface or the stem scar areas of the tomatoes, which were then sealed in plastic film bags and subjected to in-package ozonation. L. innocua on tomatoes was reduced to nondetectable levels within 40 s of treatment on the tomato surface, with inactivation of ca. 4 log CFU per fruit on the stem scar area. An increase in treatment time did not result in a proportional increase in bacterial reduction. For E. coli O157:H7 and Salmonella, there was little difference (<1 log) in the effectiveness of the system when comparing surface and scar-inoculated bacteria. Both bacteria were typically reduced by 2 to 3 log CFU per fruit after 2- to 3-min treatments. No negative effects on fruit color or texture were observed during a 22-day posttreatment storage study of ozone-treated tomatoes. These results suggest that the three bacteria responded differently to ozonation and that in-package ozonation may provide an alternative to chemical sanitizers commonly used by the industry.


2001 ◽  
Vol 64 (11) ◽  
pp. 1655-1660 ◽  
Author(s):  
J. M. McEVOY ◽  
A. M. DOHERTY ◽  
J. J. SHERIDAN ◽  
I. S. BLAIR ◽  
D. A. McDOWELL

This study used a laboratory-scale apparatus to apply subatmospheric steam to bovine hide pieces inoculated with Escherichia coli O157:H7 in maximum recovery diluent (MRD) and in high–liquid content and low–liquid content fecal suspensions (HLC fecal and LLC fecal, respectively). The survival of the organism in fecal clods, which were stored for 24 days in a desiccated state, was assessed. Inoculated fecal clods were also treated with subatmospheric steam. Steam treatment at 80 ± 2°C for 20 s reduced E. coli O157:H7 concentrations on hide inoculated to initial concentrations of approximately 7 log10 CFU/g by 5.46 (MRD inoculum), 4.17 (HLC fecal inoculum), and 5.99 (LLC fecal inoculum) log10 CFU/g. The reductions achieved in samples inoculated with LLC feces were larger than in samples inoculated with HLC feces (P < 0.05). Treatment at 80 ± 2°C for 10 s resulted in significantly smaller reductions (P < 0.05) on hide pieces of 2.54 (MRD), 1.94 (HLC fecal), and 2.15 (LLC fecal) log10 CFU/g. There were no significant differences among the reductions observed in all inoculum types in samples treated for 10 s. E. coli O157:H7 inoculated in fecal clods to 7.78 log10 CFU/g and stored at 4 or 15°C survived for at least 24 days. Steam treatment (20 s) of 3-day-old clods reduced surviving E. coli O157:H7 numbers from 4.20 log10 CFU/g to below the limit of detection of the assay used (1.20 log10 CFU/g). This study shows that steam condensing at or below 80 ± 2°C can reduce E. coli O157:H7 when present on bovine hide, reducing the risk of cross contamination to the carcass during slaughter and dressing.


2018 ◽  
Vol 19 (0) ◽  
Author(s):  
Priscila Alves Dias ◽  
Daiani Teixeira Silva ◽  
Cláudio Dias Timm

Resumo Kefir é o produto da fermentação do leite pelos grãos de kefir. Esses grãos contêm uma mistura simbiótica de bactérias e leveduras imersas em uma matriz composta de polissacarídeos e proteínas. Muitos benefícios à saúde humana têm sido atribuídos ao kefir, incluindo atividade antimicrobiana contra bactérias Gram positivas e Gram negativas. A atividade antimicrobiana de 60 microrganismos isolados de grãos de kefir, frente à Escherichia coli O157:H7, Salmonella enterica subsp. enterica sorotipos Typhimurium e Enteritidis, Staphylococcus aureus e Listeria monocytogenes, foi estudada através do teste do antagonismo. A ação antimicrobiana dos sobrenadantes das bactérias ácido-lácticas que apresentaram atividade no teste do antagonismo foi testada. O experimento foi repetido usando sobrenadantes com pH neutralizado. Salmonella Typhimurium e Enteritidis sobreviveram por 24 horas no kefir em fermentação. E. coli O157:H7, S. aureus e L. monocytogenes foram recuperados até 72 horas após o início da fermentação. Todos os isolados apresentaram atividade antimicrobiana contra pelo menos um dos patógenos usados no teste do antagonismo. Sobrenadantes de 25 isolados apresentaram atividade inibitória e três mantiveram essa atividade com pH neutralizado. As bactérias patogênicas estudadas sobreviveram por tempo superior àquele normalmente utilizado para a fermentação do kefir artesanal, o que caracteriza perigo em potencial para o consumidor quando a matéria-prima não apresentar segurança sanitária. Lactobacillus isolados de grãos de kefir apresentam atividade antimicrobiana contra cepas de E. coli O157:H7, Salmonella sorotipos Typhimurium e Enteritidis, S. aureus e L. monocytogenes além daquela exercida pela diminuição do pH.


Sign in / Sign up

Export Citation Format

Share Document