Lap Splice Test of SD400 D10 Reinforcing Bars Confined with Spiral or U-Bar

2021 ◽  
Vol 33 (4) ◽  
pp. 389-398
Author(s):  
Jin-Gyu Kim ◽  
Sung-Chul Chun ◽  
In-Ho Kim
Keyword(s):  
2021 ◽  
Vol 13 (6) ◽  
pp. 3482
Author(s):  
Seoungho Cho ◽  
Myungkwan Lim ◽  
Changhee Lee

High-strength reinforcing bars have high yield strengths. It is possible to reduce the number of reinforcing bars placed in a building. Accordingly, as the amount of reinforcement decreases, the spacing of reinforcing bars increases, workability improves, and the construction period shortens. To evaluate the structural performance of high-strength reinforcing bars and the joint performance of high-strength threaded reinforcing bars, flexural performance tests were performed in this study on 12 beam members with the compressive strength of concrete, the yield strength of the tensile reinforcing bars, and the tensile reinforcing bar ratio as variables. The yield strengths of the tensile reinforcement and joint methods were used as variables, and joint performance tests were performed for six beam members. Based on this study, the foundation for using high-strength reinforcing bars with a design standard yield strength equal to 600 MPa was established. Accordingly, mechanical joints of high-strength threaded reinforcing bars (600 and 670 MPa) can be used. All six specimens were destroyed under more than the expected nominal strength. Lap splice caused brittle fractures because it was not reinforced in stirrup. Increases of 21% to 47% in the loads of specimens using a coupler and a lock nut were observed. Shape yield represents destruction—a section must ensure sufficient ductility after yielding. Therefore, a coupler and lock nut are effective.


Structures ◽  
2019 ◽  
Vol 19 ◽  
pp. 362-368 ◽  
Author(s):  
Hussein Al-Quraishi ◽  
Mahdi Al-Farttoosi ◽  
Raad AbdulKhudhur

2018 ◽  
Vol 2018 ◽  
pp. 1-10
Author(s):  
Wonchang Choi ◽  
Seok-Joon Jang ◽  
Hyun-Do Yun

This research investigates the interfacial behavior between polyethylene (PE) fiber-reinforced strain-hardening cement composite (PE-SHCC) and reinforcing bars that are spliced in the tension region to determine feasibility of reduced lap-spliced length in PE-SHCC. Twenty test specimens were subjected to monotonic and cyclic tension loads. The variables include the replacement levels of an expansive admixture (0% and 10%), the compressive strength of the SHCC mixtures (40 MPa and 80 MPa), and the lap-spliced length in the tension region (40% and 60% of the splice length recommended by ACI 318). The PE-SHCC mixture contains polyethylene fiber to enhance the tensile strength, control the widths of the cracks, and increase the bond strength of the lap splice reinforcement and the calcium sulfo-aluminate- (CSA-) based expansive admixture to improve the tension-related performance in the lap splice zone. The results have led to the conclusion that SHCC mixtures can be used effectively to reduce the development length of lap splice reinforcement up to 60% of the splice length that is recommended by ACI 318. The addition of the calcium sulfo-aluminate-based expansive admixture in the SHCC mixtures improved the initial performance and mitigated the cracking behavior in the lap splice region.


2016 ◽  
Vol 113 (4) ◽  
Author(s):  
Jiqiu Yuan ◽  
Matthew O’Reilly ◽  
Adolfo Matamoros ◽  
David Darwin
Keyword(s):  