scholarly journals Local Bond Strength based Lap Splice Length Model of Reinforcing Bars

Author(s):  
HYEON JONG HWANG
2019 ◽  
Vol 5 (3) ◽  
pp. 255
Author(s):  
G M Sadiqul Islam ◽  
Ehsan Ahmed ◽  
Md. Sabbir Hossain ◽  
S. M. Sharif Uddin

Fusion-bonded epoxy-coated steel is expected to extend the service life of the reinforced concrete structure in chloride-laden environments. However, the effect of coating on the bond-strength between rebar and concrete is not well understood yet. This research, therefore, studied the effect of epoxy-coating on the bond characteristics of reinforcing bars in concrete. The bond characteristics were assessed through pullout test considering variables viz. concrete strength, embedded length and bar diameter. The load was applied to reinforcing bars embedded in concrete until bond strength between the bar and concrete exceeded. Bond strength of epoxy-coated bars was compared with that of the uncoated bars. It was found that epoxy-coating reduced the bond strength approximately 25% for Ø20mm bar and 12% for Ø16mm and Ø12mm bar. As with uncoated bar, bond strength of coated bars were also increased with concrete strength. However, the bond strength ratio between coated and uncoated bars was found almost independent of concrete strength. Based on the test results, a development length modification factor of 1.33 is proposed for Ø20mm bar and 1.15 for Ø12mm and Ø16mm bar to compensate the bond strength reduction due to the epoxy coating.


2021 ◽  
Vol 13 (6) ◽  
pp. 3482
Author(s):  
Seoungho Cho ◽  
Myungkwan Lim ◽  
Changhee Lee

High-strength reinforcing bars have high yield strengths. It is possible to reduce the number of reinforcing bars placed in a building. Accordingly, as the amount of reinforcement decreases, the spacing of reinforcing bars increases, workability improves, and the construction period shortens. To evaluate the structural performance of high-strength reinforcing bars and the joint performance of high-strength threaded reinforcing bars, flexural performance tests were performed in this study on 12 beam members with the compressive strength of concrete, the yield strength of the tensile reinforcing bars, and the tensile reinforcing bar ratio as variables. The yield strengths of the tensile reinforcement and joint methods were used as variables, and joint performance tests were performed for six beam members. Based on this study, the foundation for using high-strength reinforcing bars with a design standard yield strength equal to 600 MPa was established. Accordingly, mechanical joints of high-strength threaded reinforcing bars (600 and 670 MPa) can be used. All six specimens were destroyed under more than the expected nominal strength. Lap splice caused brittle fractures because it was not reinforced in stirrup. Increases of 21% to 47% in the loads of specimens using a coupler and a lock nut were observed. Shape yield represents destruction—a section must ensure sufficient ductility after yielding. Therefore, a coupler and lock nut are effective.


2021 ◽  
Author(s):  
Aamer Abbas ◽  
◽  
Yaqoob Yaqoob ◽  
Ola Hussein ◽  
Ibrahim Al-Ani ◽  
...  

This study presents experimentally the bond behavior of light-weight concrete specimens with grouted reinforcing bars in comparison with conventional concrete specimens. A total of (9) pull-out specimens were studied; (3) specimens of conventional concrete, (3) specimens of light-weight concrete, and other (3) specimens of grouted light-weight concrete. Two variables are adopted in this investigation: specimen width and type of concrete (conventional concrete, light-weight concrete and grouted light-weight concrete). The study contains a discussion of the general behavior of the specimens in addition to the study of the ultimate bond capacity, maximum bond stresses and the relationship between the stress and the slip for different pull-out specimens. Results show that bond strength is highest for the largest specimen size (bond strength of grouted light-weight concrete specimen with specimen width 400 mm is higher than that of the specimen with (200 mm) width by about (13.13%)). Also, bond strength is highest for the grouted light-weight concrete specimen (bond strength of grouted light-weight concrete specimen is higher than conventional concrete specimen by (11.11%)).


2021 ◽  
Vol 33 (4) ◽  
pp. 389-398
Author(s):  
Jin-Gyu Kim ◽  
Sung-Chul Chun ◽  
In-Ho Kim
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document