scholarly journals FAULT DIAGNOSIS OF POWER TRANSFORMER BASED ON DISSOLVED GAS ANALYSIS AND ADAPTIVE NEURO-FUZZY INFERENCE SYSTEM

Author(s):  
PALLAVI PATIL ◽  
VIKAL INGLE

Power Transformers are a vital link in a power system. Well-being of power transformer is very much important to the reliable operation of the power system. Dissolved Gas Analysis (DGA) is one for the effective tool for monitoring the condition of the transformer. To interpret the DGA result multiple techniques are available.IEC codes are developed to diagnose transformer faults. But there are cases of errors and misleading judgment due to borderline and multiple faults. Methods were developed to solve this problem by using fuzzy membership functions to map the IEC codes and heuristic experience to adjust the fuzzy rule. This paper proposes a neuro-fuzzy method to perform self learning and auto rule adjustment for producing best rules.

2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Nandkumar Wagh ◽  
D. M. Deshpande

Continuity of power supply is of utmost importance to the consumers and is only possible by coordination and reliable operation of power system components. Power transformer is such a prime equipment of the transmission and distribution system and needs to be continuously monitored for its well-being. Since ratio methods cannot provide correct diagnosis due to the borderline problems and the probability of existence of multiple faults, artificial intelligence could be the best approach. Dissolved gas analysis (DGA) interpretation may provide an insight into the developing incipient faults and is adopted as the preliminary diagnosis tool. In the proposed work, a comparison of the diagnosis ability of backpropagation (BP), radial basis function (RBF) neural network, and adaptive neurofuzzy inference system (ANFIS) has been investigated and the diagnosis results in terms of error measure, accuracy, network training time, and number of iterations are presented.


Sensors ◽  
2021 ◽  
Vol 21 (6) ◽  
pp. 2223 ◽  
Author(s):  
Sayed A. Ward ◽  
Adel El-Faraskoury ◽  
Mohamed Badawi ◽  
Shimaa A. Ibrahim ◽  
Karar Mahmoud ◽  
...  

Power transformers are considered important and expensive items in electrical power networks. In this regard, the early discovery of potential faults in transformers considering datasets collected from diverse sensors can guarantee the continuous operation of electrical systems. Indeed, the discontinuity of these transformers is expensive and can lead to excessive economic losses for the power utilities. Dissolved gas analysis (DGA), as well as partial discharge (PD) tests considering different intelligent sensors for the measurement process, are used as diagnostic techniques for detecting the oil insulation level. This paper includes two parts; the first part is about the integration among the diagnosis results of recognized dissolved gas analysis techniques, in this part, the proposed techniques are classified into four techniques. The integration between the different DGA techniques not only improves the oil fault condition monitoring but also overcomes the individual weakness, and this positive feature is proved by using 532 samples from the Egyptian Electricity Transmission Company (EETC). The second part overview the experimental setup for (66/11.86 kV–40 MVA) power transformer which exists in the Egyptian Electricity Transmission Company (EETC), the first section in this part analyzes the dissolved gases concentricity for many samples, and the second section illustrates the measurement of PD particularly in this case study. The results demonstrate that precise interpretation of oil transformers can be provided to system operators, thanks to the combination of the most appropriate techniques.


2013 ◽  
Vol 2013 ◽  
pp. 1-7 ◽  
Author(s):  
Nitin K. Dhote ◽  
Jagdish B. Helonde

Dissolved gas analysis (DGA) of transformer oil has been one of the most reliable techniques to detect the incipient faults. Many conventional DGA methods have been developed to interpret DGA results obtained from gas chromatography. Although these methods are widely used in the world, they sometimes fail to diagnose, especially when DGA results fall outside conventional methods codes or when more than one fault exist in the transformer. To overcome these limitations, the fuzzy inference system (FIS) is proposed. Two hundred different cases are used to test the accuracy of various DGA methods in interpreting the transformer condition.


Energies ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 1009 ◽  
Author(s):  
Rahman Azis Prasojo ◽  
Harry Gumilang ◽  
Suwarno ◽  
Nur Ulfa Maulidevi ◽  
Bambang Anggoro Soedjarno

In determining the severity of power transformer faults, several approaches have been previously proposed; however, most published studies do not accommodate gas level, gas rate, and Dissolved Gas Analysis (DGA) interpretation in a single approach. To increase the reliability of the faults’ severity assessment of power transformers, a novel approach in the form of fuzzy logic has been proposed as a new solution to determine faults’ severity using the combination of gas level, gas rate, and DGA interpretation from the Duval Pentagon Method (DPM). A four-level typical concentration and rate were established based on the local population. To simplify the assessment of hundreds of power transformer data, a Support Vector Machine (SVM)-based DPM with high agreements to the graphical DPM has been developed. The proposed approach has been implemented to 448 power transformers and further implementation was done to evaluate faults’ severity of power transformers from historical DGA data. This new approach yields in high agreement with the previous methods, but with better sensitivity due to the incorporation of gas level, gas rate, and DGA interpretation results in one approach.


2020 ◽  
Vol 10 (13) ◽  
pp. 4440 ◽  
Author(s):  
Yongxin Liu ◽  
Bin Song ◽  
Linong Wang ◽  
Jiachen Gao ◽  
Rihong Xu

The transformers work in a complex environment, which makes them prone to failure. Dissolved gas analysis (DGA) is one of the most important methods for oil-immersed transformers’ internal insulation fault diagnosis. In view of the high correlation of the same fault data of transformers, this paper proposes a new method for transformers’ fault diagnosis based on correlation coefficient density clustering, which uses density clustering to extrapolate the correlation coefficient of DGA data. Firstly, we calculated the correlation coefficient of dissolved gas content in the fault transformers oil and enlarged the correlation of the same fault category by introducing the amplification coefficient, and finally we used the density clustering method to cluster diagnosis. The experimental results show that the accuracy of clustering is improved by 32.7% compared with the direct clustering judgment without using correlation coefficient, which can effectively cluster different types of transformers fault modes. This method provides a new idea for transformers fault identification, and has practical application value.