scholarly journals Ultrasound in the Diagnosis of Deep Endometriosis

Author(s):  
Silvia Ajossa ◽  
Anna Maria Paoletti ◽  
Nicoletta Garau ◽  
Valerio Mais ◽  
Bruno Piras ◽  
...  

Abstract Deep pelvic endometriosis is defined as subperitoneal infiltration of endometrial implants in the uterosacral ligaments, rectum, rectovaginal septum, vagina, or bladder. Although laparoscopy and biopsy remain the gold standard for diagnosis, transvaginal ultrasonography should be considered as the first-line procedure because of its high diffusion and relatively low cost and discomfort. We analyzed in the present review the diagnostic capability of transvaginal ultrasonography in the detection of presence of deep endometriosis in some specific pelvic localizations such as bowel, uterosacral ligaments, rectovaginal septum and/or vagina. We also analyzed the few studies performed in the evaluation of bladder endometriosis. Although some studies are controversial, transvaginal ultrasonography seems to be an accurate technique in the identifications of deep endometriosis in several pelvic locations but a specific training of the operators is suggested.

2019 ◽  
Vol 52 (5) ◽  
pp. 337-341 ◽  
Author(s):  
Jorge Gilmar Amaral de Oliveira ◽  
Vanessa Bonfada ◽  
Janice de Fátima Pavan Zanella ◽  
Janaina Coser

Abstract Endometriosis is characterized by the presence of endometrial tissue outside the uterus. When endometrial implants penetrate more than 5 mm into the peritoneum, the condition is referred to as deep pelvic endometriosis. Although laparoscopy is the gold standard test to establish a diagnosis of deep endometriosis, transvaginal ultrasound represents an alternative that can contribute to detection of the disease, because it is an accessible, low-cost, noninvasive examination that allows preoperative planning in cases requiring surgical treatment. However, in clinical practice, transvaginal ultrasound is still not widely used as the first-line examination in suspected cases of endometriosis. This essay describes the findings of deep endometriosis on transvaginal ultrasound, in order to disseminate knowledge of the utility of the technique for the diagnosis of this disease.


2021 ◽  
Author(s):  
Manoel Orlando Goncalves ◽  
Joao Siufi Neto ◽  
Marina Paula Andres ◽  
Daniela Siufi ◽  
Leandro Accardo de Mattos ◽  
...  

Abstract STUDY QUESTION What is the sensitivity and the specificity of preoperative transvaginal ultrasound with bowel preparation (TVUS-BP) compared to diagnostic laparoscopy (DL) for the identification of ovarian and deep sites of endometriosis? SUMMARY ANSWER DL was able to detect retrocervical, ovarian, and bladder endometriosis with similar sensitivity and specificity as TVUS-BP, whereas for vaginal and rectosigmoid endometriosis, DL had lower sensitivity and specificity than TVUS-BP. WHAT IS KNOWN ALREADY TVUS-BP is a non-invasive examination with good accuracy for diagnosing ovarian and deep endometriosis. DL is expensive and can lead to surgical complications. STUDY DESIGN, SIZE, DURATION This prospective study included a total of 120 consecutive patients who underwent surgery for suspected endometriosis with preoperative imaging (TVUS-BP), including a video of the laparoscopic procedure, between March 2017 and September 2019. PARTICIPANTS/MATERIALS, SETTING, METHODS Two radiologists performed preoperative TVUS-BP using the same protocol for diagnosing endometriosis. Two surgeons, who were blinded to the results of the preoperative imaging and clinical data, reviewed the surgical videos from the entry of the abdominal cavity until the surgeon finalized a complete and systematic review prior to beginning any dissection (considered as a DL). A data sheet was used by surgeons and radiologists to record the sites and size of disease involvement, the American Society for Reproductive Medicine (ASRM) stage, and the Enzian score. The surgical visualization of endometriosis lesions that were confirmed by histological analysis was the gold standard. MAIN RESULTS AND THE ROLE OF CHANCE DL was able to detect retrocervical, ovarian, and bladder endometriosis with similar sensitivity and specificity as TVUS-BP. DL was not able to detect vaginal endometriosis (sensitivity and specificity 0%): this is compared to a sensitivity and specificity of 85.7% and 99.1%, respectively with the utilization of a preoperative TVUS-BP. In addition, DL was notably poor at detecting rectosigmoid endometriosis, with a sensitivity of 3.7–5.6%, and this compares to 96.3% sensitivity with utilization of a preoperative TVUS (P < 0.001). For the ASRM stage, TVUS-BP results were highly correlated with the degree of endometriosis and pouch of Douglas (POD) obliteration (weighted Kappa of 0.867 and 0.985, respectively). For the Enzian score, there was a substantial correlation between TVUSP-BP and DL for compartment A (weighted Kappa = 0.827), compartment B (weighted Kappa = 0.670), and compartment C (weighted kappa = 0.814). LIMITATIONS, REASONS FOR CAUTION The number of participants included may be a limitation in this study and, as the evaluators were blinded to the physical exam, the DL accuracy could be underestimated. As biopsies of pelvic organs were obtained only if there was a suspicion of endometriosis, the gold standard was not always applicable. This aspect could underestimate the prevalence of lesions and overestimate the sensitivity and the specificity of both the TVUS-BP and the DL. WIDER IMPLICATIONS OF THE FINDINGS Preoperative TVUS-BP was accurate in identifying all sites of ovarian and deep endometriosis that were evaluated. It had significantly higher sensitivity than DL in detecting rectosigmoid endometriosis and predicting intraoperative ASRM staging and the Enzian score. These results suggest that TVUS-BP can replace DL for the diagnosis and treatment planning for patients with ovarian and deep endometriosis. STUDY FUNDING/COMPETING INTEREST(S) The authors declare no source of funding or conflicts of interest. TRIAL REGISTRATION NUMBER N/A


Author(s):  
Fabio Barra ◽  
Franco Alessandri ◽  
Carolina Scala ◽  
Simone Ferrero

<b><i>Objective:</i></b> The use of three-dimensional (3D) transvaginal ultrasonography (TVS) has been investigated for the diagnosis of deep endometriosis (DE). This study aimed to evaluate if 3D reconstructions improve the performance of TVS) in assessing the presence and characteristics of bladder endometriosis (BE). <b><i>Design:</i></b> This was a single-center comparative diagnostic accuracy study. <b><i>Participants/Materials, Setting, Methods:</i></b> Patients referred to our institution (Piazza della Vittoria 14 Srl, Genova, Italy) with clinical suspicion of DE were included. In case of surgery, women underwent systematic preoperative ultrasonographic imaging; an experienced sonographer performed a conventional TVS; another experienced sonographer, blinded to results of the previous exam, performed TVS, with the addition of 3D modality. The presence and characteristics of BE nodules were described in accord with International DE Analysis group consensus. Ultrasound data were compared with surgical and histological results. <b><i>Results:</i></b> Overall, BE was intraoperatively found in 34 out of 194 women who underwent surgery for DE (17.5%; 95% confidence interval: 12.8–23.5%). TVS without and with 3D reconstructions were able to detect endometriotic BE in 82.2% (<i>n</i> = 28/34) and 85.3% (<i>n</i> = 29/34) of the cases (<i>p</i> = 0.125). Both the exams similarly estimated the largest diameter of BE (<i>p</i> = 0.652) and the distance between the endometriotic nodule and the closest ureteral meatus (<i>p</i> = 0.341). However, TVS with 3D reconstructions was more precise in estimating the volume of BE (<i>p</i> = 0.031). In one case (2.9%), TVS without and with 3D reconstructions detected the infiltration of the intramural ureter, which was confirmed at surgery and required laparoscopic ureterovesical reimplantation. <b><i>Limitations:</i></b> The extensive experience of the gynecologists performing the ultrasonographic scans, the lack of prestudy power analysis, and the population selected, which may have been influenced by the position of the institution as a referral center specialized in the treatment of severe endometriosis, are limitations of the current study. <b><i>Conclusion:</i></b> Our results demonstrated the high accuracy of ultrasound for diagnosing BE. The addition of 3D reconstructions does not improve the performance of TVS in diagnosing the presence and characteristics of BE. However, the volume of BE may be more precisely assessed by 3D ultrasound.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ananthamurthy Koteshwara ◽  
Nancy V. Philip ◽  
Jesil Mathew Aranjani ◽  
Raghu Chandrashekhar Hariharapura ◽  
Subrahmanyam Volety Mallikarjuna

AbstractA carefully designed ammonium sulfate precipitation will simplify extraction of proteins and is considered to be a gold standard among various precipitation methods. Therefore, optimization of ammonium sulfate precipitation can be an important functional step in protein purification. The presence of high amounts of ammonium sulphate precludes direct detection of many enzymatically active proteins including reducing sugar assays (e.g. Nelson-Somogyi, Reissig and 3,5-dinitrosalicylic acid methods) for assessing carbohydrases (e.g. laminarinase (β (1–3)-glucanohydrolase), cellulases and chitinases). In this study, a simple method was developed using laminarin infused agarose plate for the direct analysis of the ammonium sulphate precipitates from Streptomyces rimosus AFM-1. The developed method is simple and convenient that can give accurate results even in presence of ammonium sulfate in the crude precipitates. Laminarin is a translucent substrate requiring the use of a stain to visualize the zones of hydrolysis in a plate assay. A very low-cost and locally available fluorescent optical fabric brightener Tinopal CBS-X has been used as a stain to detect the zones of hydrolysis. We also report simple methods to prepare colloidal chitin and cell free supernatant in this manuscript.


2020 ◽  
Vol 56 (S1) ◽  
pp. 340-340
Author(s):  
S. Guerriero ◽  
M. Pascual ◽  
B. Graupera ◽  
M. Neri ◽  
F. Conway ◽  
...  

2021 ◽  
Vol 4 (Supplement_1) ◽  
pp. 210-212
Author(s):  
R Trasolini ◽  
S Wong ◽  
B Salh

Abstract Background Fecal calprotectin is a non-invasive test of colonic inflammation used for monitoring inflammatory bowel disease activity and for risk stratifying non-specific colonic symptoms. Calprotectin is a leukocyte specific enzyme. A similar test, leukocyte esterase is used to detect leukocytes in urine and is widely available as a low-cost point-of-care test strip. We hypothesize that an unmodified version of the urine test strip would be highly accurate in predicting a positive fecal calprotectin test in a real world sample of patients. Aims To explore a low cost, rapid alternative to the fecal calprotectin test Methods All inpatient and outpatient stool samples tested for calprotectin by the Vancouver General Hospital laboratory from February 2020 to November 2020 were included prospectively. Samples were simultaneously tested for fecal leukocyte esterase using an unmodified Roche Cobas Chemstrip urinalysis test strip by central lab personnel. An identical aliquot was sent to LifeLabs for calprotectin as per standard protocol. All samples were suspended in buffer using established laboratory protocols prior to testing. Fecal leukocyte esterase results were reported as 0–4+ based on visual interpretation, calprotectin results were reported as mcg/g of stool. REB review and approval was obtained prior to data collection. Sensitivity, Specificity and AUROC were calculated using Microsoft Excel and JROCFIT. Results 26 samples were collected. Using a fecal calprotectin greater than 120 mcg/g as a gold standard an AUROC of 0.89 (SE= .06) was calculated. A leukocyte esterase reading of 2+ or greater had the best test characteristics based on ROC curve analysis. Using this cutoff, 21/26 samples were concordant, giving an accuracy of 80.8%, sensitivity of 90.9% and specificity of 73.3%. Positive likelihood ratio was 8.07 and negative likelihood ratio was 0.29. Assuming an AUROC of 0.8, the sample size N=26 is 90% powered (β=0.9) to predict the true AUROC within 0.1 with a type I error rate of .05 (α&lt;.05). Conclusions This study suggests application of a prepared stool sample to a urinalysis test strip gives a result highly predictive of a positive fecal calprotectin test. Further results are being collected prospectively to improve the robustness of these preliminary data. Secondary outcomes including comparison to endoscopy and biopsy results where available are planned if an adequate sample size can be accrued. Future studies justifying independent clinical use of leukocyte esterase would require a common gold standard comparator such as endoscopy. Fecal calprotectin testing is not universally insured and is not available as a rapid test strip. Use of fecal leukocyte esterase may reduce costs and shorten time to results if proven to be independently reliable. Funding Agencies None


1989 ◽  
Vol 31 (4) ◽  
pp. 279-285 ◽  
Author(s):  
M.E. Camargo ◽  
Maria Emilia G. Moura ◽  
P.G. Leser

In search of an efficient but simple, low cost procedure for the serodiagnosis of Toxoplasmosis, especially suited for routine laboratories facing technical and budget limitations as in less developed countries, the diagnostic capability of Hematoxo® , an hemagglutination test for toxoplasmosis, was evaluated in relation to a battery of tests including IgG- and IgM-immunofluorescence tests, hemagglutination and an IgM-capture enzymatic assay. Detecting a little as 5 I.U. of IgG antitoxoplasma antibodies, Hematoxo® showed a straight agreement as to reactivity and non-reactivity for the 443 non-reactive and the 387 reactive serum samples, included in this study. In 23 cases presenting a serological pattern of acute toxoplasmosis and showing IgM antibodies, Hematoxo® could detect IgM antibodies in 18, indicated by negativation or a significant decrease in titers as a result of treating samples with 2-mercapto-ethanol. However, a neat increase in sensitivity for IgM specific antibodies could be achieved by previously removing IgG from the sample, as demonstrated in a series of acute toxoplasmosis sera. A simple procedure was developed for this purpose, by reconstituting a lyophilized suspension of Protein A - rich Staphylococcus with the lowest serum dilution to be tested. Of low cost and easy to perform, Hematoxo® affords not only a practical qualitative procedure for screening reactors and non-reactors, as in prenatal services, but also quantitative assays that permit to titrate antibodies as well as to identify IgM antibodies.


2000 ◽  
Vol 6 (1_suppl) ◽  
pp. 35-37 ◽  
Author(s):  
L E Graham ◽  
S Mcgimpsey ◽  
S Wright ◽  
G Mcclean ◽  
J Carser ◽  
...  

We have investigated prospectively the diagnostic accuracy, specialist satisfaction and patient–specialist rapport of a low-cost audio-visual link between a junior doctor with a patient and a consultant rheumatologist. Using a telephone link and subsequently a video-phone link, 20 patients, with various rheumatological problems, were presented by a junior doctor to the consultant rheumatologist for provisional diagnosis. All patients were then seen face to face by the consultant, when a final diagnosis was made. An independent consultant rheumatologist made a ‘gold standard’ diagnosis. Thirty-five per cent of diagnoses were made correctly over the telephone and 40% over the video-phone – there was no significant difference in the diagnostic accuracy between these two methods of communication. Rapport over the video-phone was universally poor. Where it was important, clinical signs could not be visualized over the video-phone and in more than 85% of cases small joint swellings could not be seen clearly.


2019 ◽  
Author(s):  
Renaud Hage ◽  
Christine Detrembleur ◽  
Frédéric Dierick ◽  
Laurent Pitance ◽  
Laurent Jojczyk ◽  
...  

Various noninvasive measurement devices can be used to assess cervical motion. Size, complexity and cost of gold-standard systems make them not suited in clinical practice, and actually difficult to use outside dedicated laboratory. Nowadays, ultra-low-cost inertial measurement units are available but without any packaging nor user-friendly interface. DYSKIMOT is a home- designed, small-sized, motion sensor based on the latter technology, aiming at being used by clinicians in “real-life situations”. In the present study. DYSKIMOT was compared with a gold- standard optoelectronic system (Elite). Our goal was to evaluate the accuracy of DYSKIMOT in assessing the kinematics in fast head rotations. Kinematics was simultaneously recorded by the DYSKIMOT and Elite systems during the execution of the DidRen Laser test and performed by 15 participants and 9 patients. Kinematic variables were computed from the position, speed and acceleration time series. Two-way ANOVA, Passing-Bablok regressions and Dynamic Time Warping analysis showed good to excellent agreement between Elite and DYSKIMOT, both at the qualitative level of the time series shape and at the quantitative level of peculiar kinematical events’ measured values. In conclusion, DYSKIMOT sensor is as relevant as a gold-standard system to assess kinematical features during fast head rotations in participants and patients, demonstrating its usefulness in clinical practice or research in ecological environment.


Sign in / Sign up

Export Citation Format

Share Document