scholarly journals Effect of Post Space Irrigation using Novel Irrigant: SmearOFF (containing Chlorhexidine and EDTA) on the Push-out Bond Strength of Fiber Posts luted with Self-adhesive Resin Cement

2018 ◽  
Vol 3 (1) ◽  
pp. 7-11
Author(s):  
Vibha Hegde ◽  
Amrita V Sali
2016 ◽  
Vol 45 (4) ◽  
pp. 227-233
Author(s):  
Adriana Rosado Valente ANDRIOLI ◽  
Margareth COUTINHO ◽  
Andréa Araújo de VASCONCELLOS ◽  
Milton Edson MIRANDA

Abstract Introduction The correct use of glass fiber posts in endodontically treated teeth is essential for the clinical success of restorative treatment. Objective This study evaluated the push-out shear bond strength of relined (R) or non-relined (NR) glass fiber posts, cemented with self-adhesive resin cement [RelyXTM U100 (U100)] and conventional resin cement [RelyXTM ARC (ARC)]. Material and method Sixty human single-rooted teeth were endodontically treated and divided into ARC-NR; U100-NR; ARC-R; U100-R groups. The teeth were sectioned into cervical, middle and apical thirds, and subjected to the push-out test. Bond strength was analyzed by the Friedman test; cement and post types were compared by the Mann Whitney test. The pattern of failures was evaluated with digital camera through images at 200x magnification, and was classified as adhesive (at the cement/dentin or cement/post interface), cohesive (cement or post), and mixed failures. Result In ARC-NR, bond strength values were higher in the cervical third; in U100-NR and ARC-R they were similar between the thirds. In U100-R, in the cervical and middle thirds the bond strength values were similar, and there was lower value in the apical third. For non-relined glass fiber posts, the highest mean bond strength values were observed with self-adhesive resin cement. Whereas, relined posts cemented with conventional resin cement had stronger cement layer in comparison with non-relined fiber posts. Conclusion The post relining technique was efficient in ARC-R. ARC-NR and U100-R showed improved bond strength in the cervical region of canal walls. The main failures were adhesive at the cement-post interface.


2020 ◽  
Vol 45 (4) ◽  
pp. E185-E195
Author(s):  
RV Machry ◽  
PE Fontana ◽  
TC Bohrer ◽  
LF Valandro ◽  
OB Kaizer

Clinical Relevance When luting relined fiber posts with self-adhesive cement, the surface treatment of the posts influences the adhesion of the fiber posts to root dentin. SUMMARY This study evaluated the effect of surface treatment and silanization of resin composite on the bond strength of relined fiber posts cemented with self-adhesive resin cement. Push-out and microtensile bond strength (MTBS) tests were performed in this study. The endodontic treatment of 80 single-rooted bovine teeth was first performed in the push- out test segment, followed by weakening the intracanal walls by diamond bur. Then, the glass fiber posts were adapted with resin composite to fill the root canals, followed by photoactivation and resin surface conditioning according to four different experimental conditions: no conditioning as control, 10% hydrofluoric acid, 35% hydrogen peroxide, or air abrasion with alumina particle (all groups were subdivided into “with silanization” or “without silanization,” thus totaling eight experimental groups). Self-adhesive resin cement was used for the post cementation. Four slices per tooth were obtained for the push-out tests. Next, 160 blocks of resin composite were first produced for the MTBS tests; their bonding surfaces were conditioned (as mentioned, ie, eight treatments), and they were cemented to each other. The 80 sets (n=10/treatment) were then cut into microbars (16/set): eight were immediately tested, while the other eight were thermocycled (12,000×) and stored (120 days) before MTBS. Failure modes and topographic analyses were performed after treatments. There was no statistically significant difference for the push-out results. In MTBS, surface treatment and silanization had a significant effect (p<0.001). Aging decreased bond strength for all groups. Considering the aged groups, air abrasion promoted the highest values and silanization improved bond strength for all treatments except air abrasion. The alumina particle air abrasion of the relining resin composite promoted the highest bond strengths when luting with self-adhesive resin cement.


2017 ◽  
Vol 2017 ◽  
pp. 1-6 ◽  
Author(s):  
Adricyla Teixeira Rocha ◽  
Leticia Machado Gonçalves ◽  
Ana Júlia de Carvalho Vasconcelos ◽  
Etevaldo Matos Maia Filho ◽  
Ceci Nunes Carvalho ◽  
...  

Aim. The aim of the study was to evaluate, by means of the push-out test, the effect of the anatomical customization of the fiber post on the bond strength of a self-adhesive resin cement. Methods. Twelve endodontically treated, human, upper central incisors were randomly divided into two groups (n=6): control (glass fiber posts cemented with Relyx® U200) and customized (glass fiber posts anatomically customized with translucent composite resin cemented with Relyx U200). The roots were sectioned into three slices, cervical, middle, and apical, and photographed with a digital camera attached to a stereomicroscopic loupe. The images were analyzed by software, for evaluation of the cement line. The slices were subsequently submitted to the push-out test until the post had completely extruded, and the fracture mode was analyzed with a stereomicroscopic loupe. Results. The results showed significant differences between the groups in the different root thirds in relation to the area occupied by air bubbles (p<0.05). Bond strength, when all the thirds are considered, was 8.77 ± 4.89 MPa for the control group and 16.96 ± 4.85 MPa for the customized group. Conclusion. The customized group showed greater bond resistance than the control group and a more uniform cement layer.


2020 ◽  
Author(s):  
Afaf Mohamed Al-Najajrah ◽  
Carl Hany Halim ◽  
Omnia Nabil

Abstract Self-adhesive resin cement is highly recommended for cementation of fiber post systems, since it binds chemically with calcium ions in the hydroxyapatite particles without surface pretreatments of dentin. Unfortunately, chelating agents that are used to remove smear layer reduce the calcium ion content of superficial dentin. This study aims to evaluate the effect of remineralization of dentin on the bonding strength of fiber post using the biomimetic remineralizing agent CPP-ACP in vitro. Such a study will provide evidence on the possibility of improving bonding strength by increasing dentin mineral content. At the same time, it should be supported by further clinical studies since it remains in vitro.21 freshly extracted single rooted teeth will be treated endodontically, prepared for post space, and divided randomly into 3 groups: EDTA+CPP-ACP, EDTA + NaOCl, EDTA alone. Fiber post will be cemented and push out bond strength will be measured for all groups. The expected time of study is 6-8 months.


2016 ◽  
Vol 19 (6) ◽  
pp. 583 ◽  
Author(s):  
RodrigoVarella de Carvalho ◽  
JoãoFernando Bazzo ◽  
MariaBeatriz Bergonse Pereira Pedriali ◽  
RicardoDanil Guiraldo ◽  
SandrineBittencourt Berger ◽  
...  

2011 ◽  
Vol 36 (6) ◽  
pp. 643-648 ◽  
Author(s):  
AA Leme ◽  
M Coutinho ◽  
AF Insaurralde ◽  
PMC Scaffa ◽  
LM da Silva

Clinical Relevance A self-adhesive resin cement can provide a significantly stronger bond than a three-step etch-and-rinse adhesive and resin cement when used to lute fiber posts.


2015 ◽  
Vol 16 (2) ◽  
pp. 147-153 ◽  
Author(s):  
Mateus Rodrigues Tonetto ◽  
Rudys Rodolfo de Jesus Tavarez ◽  
Omar El-Mowafy ◽  
Matheus Coelho Bandeca ◽  
Thiago Soares Porto ◽  
...  

ABSTRACT Purpose The purpose of this study was to evaluate the effect of self-adhesive and self-etching resin cements on the bond strength of nonmetallic posts in different root regions. Materials and methods Sixty single-rooted human teeth were decoronated, endodontically treated, post-space prepared, and divided into six groups. Glass-fiber (GF) posts (Exacto, Angelus) and fiber-reinforced composite (FRC) posts (EverStick, StickTeck) were cemented with self-adhesive resin cement (Breeze) (SA) (Pentral Clinical) and self-etching resin cement (Panavia-F) (SE) (Kuraray). Six 1-mm-thick rods were obtained from the cervical (C), middle (M), and apical (A) regions of the roots. The specimens were then subjected to microtensile testing in a special machine (BISCO; Schaumburg, IL, USA) at a crosshead speed of 0.5 mm/min. Microtensile bond strength data were analyzed with two-way ANOVA and Tukey's tests. Results Means (and SD) of the MPa were: GF/SA/C: 14.32 (2.84), GF/SA/M: 10.69 (2.72), GF/SA/A: 6.77 (2.17), GF/SE/C: 11.56 (4.13), GF/SE/M: 6.49 (2.54), GF/SE/A: 3.60 (1.29), FRC/SA/C: 16.89 (2.66), FRC/SA/M: 13.18 (2.19), FRC/SA/A: 8.45 (1.77), FRC/SE/C: 13.69 (3.26), FRC/SE/M: 9.58 (2.23), FRC/SE/A: 5.62 (2.12). The difference among the regions was statistically significant for all groups (p < 0.05). The selfadhesive resin cement showed better results than the selfetching resin cement when compared to each post (p < 0.05). No statistically significant differences in bond strengths of the resin cements when comparable to each post (p > 0.05). Conclusion The bond strength values were significantly affected by the resin cement and the highest values were found for self-adhesive resin cement. How to cite this article da Silva MB, de Jesus Tavarez RR, de Assis FS, Tonetto MR, Porto TS, Bhandi SH, El-Mowafy O, de Toledo Porto Neto S, Bandeca MC. The Effect of Self-adhesive and Self-etching Resin Cements on the Bond Strength of Nonmetallic Posts in Different Root Thirds. J Contemp Dent Pract 2015;16(2):147-153.


2016 ◽  
Vol 27 (5) ◽  
pp. 592-598 ◽  
Author(s):  
Regina Maria Helen-Cot Marcos ◽  
◽  
Gustavo Ross Kinder ◽  
Edson Alfredo ◽  
Tarcisio Quaranta ◽  
...  

Abstract The objective of the present study was to evaluate the influence of resin cement thickness on the bond strength of prefabricated and customized glass fiber posts after storage in distilled water. Thirty human uniradicular roots were treated endodontically. The roots were divided into 3 groups: THIN (thin cement layer) - post space preparation with #0.5 drill and cementation of #0.5 post; THICK (thick cement layer) - post space preparation with #1 drill and cementation of #0.5 post; and CUSTOM (customized cement layer) - post space preparation with #1 drill and cementation of a customized post (#0.5 glass fiber posts customized with resin composite). All posts were luted with self-adhesive resin cement. The push-out test was carried out after storage for 24 h and 90 days in distilled water at 37 °C. The data were analyzed with three-way ANOVA and Tukey's test (a=0.05). Bond strengths were significantly higher for CUSTOM (9.37 MPa), than for THIN (7.85 MPa) and THICK (7.07 MPa), which were statistically similar. Considering the thirds, the bond strength varied in the sequence: apical (7.13 MPa) < middle (8.22 MPa) = coronal (8.94 MPa). Bond strength for 24 h storage was significantly higher (8.80 MPa) than for 90-day storage (7.40 MPa). It may be concluded that the thickness of resin cement influenced the bond strength of glass fiber posts. The customized posts presented higher bond strength. Storage in water for 90 days affected negatively the values of bond strength, especially for thick cement layers in the apical third.


2015 ◽  
Vol 16 (7) ◽  
pp. 559-564 ◽  
Author(s):  
Matheus Coelho Bandéca ◽  
Adriano Augusto Melo de Mendonça ◽  
Etevaldo Matos Maia Filho ◽  
Fausto da Silva Bramante ◽  
Darlon Martins Lima ◽  
...  

ABSTRACT This study evaluated the influence of relining fiber posts on the bond strength (BS) of resin cements in the root canal. Forty bovine teeth were divided in four groups (n = 10)G1 (ARC)—fiber post cemented with resin cement RelyX ARC; G2 (ARC+Z350)—relined fiber post cemented with RelyX ARC; G3 (U200)—fiber post cemented with self-adhesive cement RelyX U200; G4 (U200+Z350)—relined fiber post cemented with RelyX U200. The roots were sectioned in six 1.2-mm slices and the push-out test was performed. Data were analyzed by three-way analysis of variance (ANOVA), and Tukey's test (α = 0.05). For the conventional resin cement, there was no significant difference between groups G1-ARC (15.5 ± 3.8) and G2-ARC+Z350 (16.1 ± 4.5). For the self-adhesive cement, the results revealed higher BS values for relined posts G4-U200 + Z350 (19.9 ± 7.9) as compared to non-relined posts G3-U200 (14.4 ± 4.5). For both cements, in groups of relined posts, the apical and the cervical thirds presented similar BS. Relining enhances the performance of the self-adhesive resin cement, and the interaction between relining and root third influences the BS to the conventional resin cement. How to cite this article Conde DM, Rodrigues VP, de Fátima Carvalho Souza S, Bauer JRO, da Silva Bramante F, Lima SNL, Filho EMM, Bandeca MC, de Mendonça AAM, Lima DM. Influence of Relining Post on the Bond Strength of Resin Cements. J Contemp Dent Pract 2015;16(7):559-564.


Sign in / Sign up

Export Citation Format

Share Document