scholarly journals Factors influencing breast elasticity measured by the ultrasound Shear Wave elastography – preliminary results

2011 ◽  
Vol 1 ◽  
pp. 127-133 ◽  
Author(s):  
Paweł Rzymski ◽  
Agnieszka Skórzewska ◽  
Myriam Skibińska-Zielińska ◽  
Tomasz Opala
2019 ◽  
Vol 45 (9) ◽  
pp. 2317-2327 ◽  
Author(s):  
Jing Han ◽  
Fei Li ◽  
Chuan Peng ◽  
Yini Huang ◽  
Qingguang Lin ◽  
...  

2021 ◽  
Vol 9 (6) ◽  
Author(s):  
Carmen Roch ◽  
Fernando García ◽  
María Flores ◽  
Ruben González ◽  
Miguel Cepeda ◽  
...  

In absence of pharmacological toxicity, allograft dysfunction is usually due to parenchymal inflammation and tubulointerstitial fibrosis, but its clinical signs are often non-specific and tend to appear when advanced damage has been established. We investigated whether Shear Wave Elastography (SWE), a new non-invasive ultrasound (US) based technique that estimates tissue stiffness, could provide early confident diagnosis of acute allograft dysfunction compared to biopsy (gold standard technique).


2016 ◽  
Vol 71 (1) ◽  
pp. 92-95 ◽  
Author(s):  
M. Elseedawy ◽  
P. Whelehan ◽  
S. Vinnicombe ◽  
K. Thomson ◽  
A. Evans

Author(s):  
Francesca Del Signore ◽  
Stefania De Dominicis ◽  
Giovanni Mastromatteo ◽  
Francesco Simeoni ◽  
Pier Augusto Scapolo ◽  
...  

AbstractShear wave elastography (SWE) is a feasible and newly developed ultrasonographic technique which is able to assess elasticity of tissues. The aim of this work was to assess the feasibility of SWE on the normal canine common calcaneal tendon (CCT) evaluating the intra-operator repeatability and reproducibility of single measurements and stiffness of different anatomic CCT portions was examined. Tendons were first evaluated with B-mode ultrasound with a linear probe 8.5 to 10 MHz in longitudinal section with slight flexed tarsocrural joint and a gel-pad. Common calcaneal tendon was divided into three different anatomical regions. Shear wave elastography was performed in each region by two operators and quantitative evaluation (m/s and kPa) was performed on the most representative images. Region of interest (0.15 cm) was settled. Intraclass correlation coefficient (ICC) results were classified using the following scale: 0.00 to 0.20 = poor; 0.20 to 0.40 = fair; 0.40 to 075 = good; >0.75 = excellent. Ten adult dogs were enrolled. Intra-operator ICC values were >0.75 for both operators in every tendon portion. Inter-operator SWE ICC values for m/s measurements were 0.3, 0.61 and 0.61 for the enthesis, intermediate portion and the myotendinous junction respectively; for kPa measurements, values were respectively 0.3, 0.7 and 0.81. The three CCT portions were significantly different in stiffness (p-value < 0.001 for both m/s and kPa measurements). These preliminary results provide evidence that SWE is potentially appliable to assess mechanical properties of canine CCT affected by tendinopathies.


Author(s):  
Anders Batman Mjelle ◽  
Anesa Mulabecirovic ◽  
Roald Flesland Havre ◽  
Edda Jonina Olafsdottir ◽  
Odd Helge Gilja ◽  
...  

Abstract Purpose Liver elastography is increasingly being applied in screening for and follow-up of pediatric liver disease, and has been shown to correlate well with fibrosis staging through liver biopsy. Because time is of the essence when examining children, we wanted to evaluate if a reliable result can be achieved with fewer acquisitions. Materials and Methods 243 healthy children aged 4–17 years were examined after three hours of fasting. Participants were divided into four age groups: 4–7 years; 8–11 years; 12–14 years and 15–17 years. Both two-dimensional shear wave elastography (2D-SWE; GE Logiq E9) and point shear wave elastography (pSWE; Samsung RS80A with Prestige) were performed in all participants, while transient elastography (TE, Fibroscan) was performed in a subset of 87 children aged 8–17 years. Median liver stiffness measurement (LSM) values of 3, 4, 5, 6, 7, and 8 acquisitions were compared with the median value of 10 acquisitions (reference standard). Comparison was performed for all participants together as well as within every specific age group. We investigated both the intraclass correlation coefficient (ICC) with absolute agreement and all outliers more than 10 %, 20 % or ≥ 0.5 or 1.0 kPa from the median of 10 acquisitions. Results For all three systems there was no significant difference between three and ten acquisitions, with ICCs ≥ 0.97. All systems needed 4 acquisitions to achieve no LSM deviating ≥ 1.0 kPa of a median of ten. To achieve no LSM deviating ≥ 20 % of a median of ten acquisitions, pSWE and TE needed 4 acquisitions, while 2D-SWE required 6 acquisitions. Conclusion Our results contradict recommendations of 10 acquisitions for pSWE and TE and only 3 for 2D-SWE.


Sign in / Sign up

Export Citation Format

Share Document