scholarly journals Factors affecting high cumulative radiation exposure from paediatric computed tomography

2021 ◽  
Vol 86 (1) ◽  
pp. 455-460
Author(s):  
Thipsumon Tangsiwong ◽  
Teerasak Phewplung ◽  
Panruethai Trinavarat
2018 ◽  
Vol 2 (12) ◽  
Author(s):  
Kıyasettin Asil ◽  
Bora Kalaycıoğlu ◽  
Kamran Mahmutyazıcıoğlu

2020 ◽  
Vol 3 ◽  
pp. 36-39
Author(s):  
Samson O. Paulinus ◽  
Benjamin E. Udoh ◽  
Bassey E. Archibong ◽  
Akpama E. Egong ◽  
Akwa E. Erim ◽  
...  

Objective: Physicians who often request for computed tomography (CT) scan examinations are expected to have sound knowledge of radiation exposure (risks) to patients in line with the basic radiation protection principles according to the International Commission on Radiological Protection (ICRP), the Protection of Persons Undergoing Medical Exposure or Treatment (POPUMET), and the Ionizing Radiation (Medical Exposure) Regulations (IR(ME)R). The aim is to assess the level of requesting physicians’ knowledge of ionizing radiation from CT scan examinations in two Nigerian tertiary hospitals. Materials and Methods: An 18-item-based questionnaire was distributed to 141 practicing medical doctors, excluding radiologists with work experience from 0 to >16 years in two major teaching hospitals in Nigeria with a return rate of 69%, using a voluntary sampling technique. Results: The results showed that 25% of the respondents identified CT thorax, abdomen, and pelvis examination as having the highest radiation risk, while 22% said that it was a conventional chest X-ray. Furthermore, 14% concluded that CT head had the highest risk while 9% gave their answer to be conventional abdominal X-ray. In addition, 17% inferred that magnetic resonance imaging had the highest radiation risk while 11% had no idea. Furthermore, 25.5% of the respondents have had training on ionizing radiation from CT scan examinations while 74.5% had no training. Majority (90%) of the respondents were not aware of the ICRP guidelines for requesting investigations with very little (<3%) or no knowledge (0%) on the POPUMET and the IR(ME)R respectively. Conclusion: There is low level of knowledge of ionizing radiation from CT scan examinations among requesting physicians in the study locations.


2021 ◽  
pp. 105566562110017
Author(s):  
Yoshikazu Kobayashi ◽  
Masanao Kobayashi ◽  
Daisuke Kanamori ◽  
Naoko Fujii ◽  
Yumi Kataoka ◽  
...  

Objective: Some patients with cleft palate (CP) need secondary surgery to improve functionality. Although 4-dimensional assessment of velopharyngeal closure function (VPF) in patients with CP using computed tomography (CT) has been existed, the knowledge about quantitative evaluation and radiation exposure dose is limited. We performed a qualitative and quantitative assessment of VPF using CT and estimated the exposure doses. Design: Cross-sectional. Setting: Computed tomography images from 5 preoperative patients with submucous CP (SMCP) and 10 postoperative patients with a history of CP (8 boys and 7 girls, aged 4-7 years) were evaluated. Patients: Five patients had undergone primary surgery for SMCP; 10 received secondary surgery for hypernasality. Main Outcome Measures: The presence of velopharyngeal insufficiency (VPI), patterns of velopharyngeal closure (VPC), and cross-sectional area (CSA) of VPI was evaluated via CT findings. Organ-absorbed radiation doses were estimated in 5 of 15 patients. The differences between cleft type and VPI, VPC patterns, and CSA of VPI were evaluated. Results: All patients had VPI. The VPC patterns (SMCP/CP) were evaluated as coronal (1/4), sagittal (0/1), circular (1/2), and circular with Passavant’s ridge (2/2); 2 patients (1/1) were unevaluable because of poor VPF. The CSA of VPI was statistically larger in the SMCP group ( P = .0027). The organ-absorbed radiation doses were relatively lower than those previously reported. Conclusions: Four-dimensional CT can provide the detailed findings of VPF that are not possible with conventional CT, and the exposure dose was considered medically acceptable.


2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Kyungmin Lee ◽  
Gyu-Hyoung Lee

Abstract Background Radiographs are integral in evaluating implant space and inter-root distance. The purpose of this report is to introduce a method for evaluating the 3D root position with minimal radiation using a 3D tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography (CBCT)-scanned root. Materials and methods Intraoral scan and CBCT scan of the patient were obtained before treatment. In the CBCT image, tooth segmentation was performed by isolating individual teeth from the maxillary and mandibular alveolar bone using software program. The 3D tooth model was fabricated by combining segmented individual teeth with the intraoral scan. Results A post-treatment intraoral scan was integrated into the tooth model, and the resulting position of the root could be predicted without additional radiographs. It is possible to monitor the root position after a pretreatment CBCT scan using a 3D tooth model without additional radiographs. Conclusion The application of the 3D tooth model benefits the patient by reducing repeated radiation exposure while providing the clinician with a precise treatment evaluation to monitor tooth movement.


Diagnostics ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 1286
Author(s):  
Junya Sato ◽  
Kazunari Nakahara ◽  
Yosuke Michikawa ◽  
Ryo Morita ◽  
Keigo Suetani ◽  
...  

Endoscopic transpapillary gallbladder drainage (ETGBD) for acute cholecystitis is challenging. We evaluated the influence of pre-procedural imaging and cystic duct cholangiography on ETGBD. Patients who underwent ETGBD for acute cholecystitis were retrospectively examined. The rate of gallbladder contrast on cholangiography, the accuracy of cystic duct direction and location by computed tomography (CT) and magnetic resonance cholangiopancreatography (MRCP), and the relationship between pre-procedural imaging and the technical success of ETGBD were investigated. A total of 145 patients were enrolled in this study. Gallbladder contrast on cholangiography was observed in 29 patients. The accuracy of cystic duct direction and location (proximal or distal, right or left, and cranial or caudal) by CT were, respectively, 79%, 60%, and 58% by CT and 68%, 55%, and 58% by MRCP. Patients showing gallbladder contrast on cholangiography underwent ETGBD with a significantly shorter procedure time and a lower rate of cystic duct injury. No other factors affecting procedure time, technical success, and cystic duct injury were identified. Pre-procedural evaluation of cystic duct direction and location by CT or MRCP was difficult in patients with acute cholecystitis. Patients who showed gallbladder contrast on cholangiography showed a shorter procedure time and a lower rate of cystic duct injury.


Sign in / Sign up

Export Citation Format

Share Document