scholarly journals THE IDEAL PROFILE (INCREASE IN B-LINES/DELTA B-LINES) ON LUNG ULTRASOUND FOR DIAGNOSING WEANING INDUCED PULMONARY EDEMA IN VENTILATED PATIENTS

2022 ◽  
Vol 71 (6) ◽  
pp. 2220-23
Author(s):  
Ghulam Rasheed ◽  
Zahid Siddique Shad ◽  
Tooba Mehreen ◽  
Nusrat Kharadi ◽  
Moazma Ramzan ◽  
...  

Objective: To ascertain the ideal number of B-lines on lung ultrasound for the diagnosis of weaning induced pulmonary edema in ventilated patients. Study Design: Prospective observational study. Place and Duration of Study: Department of Medicine, Shifa International Hospital, Islamabad, from Jan to Aug 2020. Methodology: All the patients over the age of 18 years who were on mechanical ventilation in a medical intensive care unit were included in the study. The patients were given spontaneous breathing trials as a protocol for weaning from mechanical ventilation. Lung ultrasound was performed on 4 points of anterior chest wall before and after spontaneous breathing trials. Before and after spontaneous breathing trials counting of B lines was done on ultrasound of lung and comparison of increase in B lines (Delta-B-lines) was done with reference diagnosis of weaning induced pulmonary edema diagnosed by intensivist who was blinded to the results of lung ultrasound. Results: The study included 42 patients including 23 (54.8%) men and 19 (45.2%) women. 14 cases failed spontaneous breathing trials. Seven cases (16.7%) had weaning induced pulmonary edema. Delta-B-lines ≥6 diagnosed weaning induced pulmonary edema with 100% accuracy. Out of the remaining seven patients with weaning failure but without weaning induced pulmonary edema, 6 (28.6%) had Delta-B-lines ≥6. The ultrasound lung technique had a 100% sensitivity profile to detect weaning induced pulmonary edema and a specificity of 77.78%. Conclusion: The study indicates that Delta-B-lines ≥6 diagnosed the weaning induced pulmonary edema with the best accuracy.

2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Alessandro Ghiani ◽  
Joanna Paderewska ◽  
Swenja Walcher ◽  
Konstantinos Tsitouras ◽  
Claus Neurohr ◽  
...  

AbstractSince critical respiratory muscle workload is a significant determinant of weaning failure, applied mechanical power (MP) during artificial ventilation may serve for readiness testing before proceeding on a spontaneous breathing trial (SBT). Secondary analysis of a prospective, observational study in 130 prolonged ventilated, tracheotomized patients. Calculated MP’s predictive SBT outcome performance was determined using the area under receiver operating characteristic curve (AUROC), measures derived from k-fold cross-validation (likelihood ratios, Matthew's correlation coefficient [MCC]), and a multivariable binary logistic regression model. Thirty (23.1%) patients failed the SBT, with absolute MP presenting poor discriminatory ability (MCC 0.26; AUROC 0.68, 95%CI [0.59‒0.75], p = 0.002), considerably improved when normalized to lung-thorax compliance (LTCdyn-MP, MCC 0.37; AUROC 0.76, 95%CI [0.68‒0.83], p < 0.001) and mechanical ventilation PaCO2 (so-called power index of the respiratory system [PIrs]: MCC 0.42; AUROC 0.81 [0.73‒0.87], p < 0.001). In the logistic regression analysis, PIrs (OR 1.48 per 1000 cmH2O2/min, 95%CI [1.24‒1.76], p < 0.001) and its components LTCdyn-MP (1.25 per 1000 cmH2O2/min, [1.06‒1.46], p < 0.001) and mechanical ventilation PaCO2 (1.17 [1.06‒1.28], p < 0.001) were independently related to SBT failure. MP normalized to respiratory system compliance may help identify prolonged mechanically ventilated patients ready for spontaneous breathing.


2019 ◽  
Vol 7 (23) ◽  
pp. 4010-4014 ◽  
Author(s):  
Samir El Hadidy ◽  
Mohamed Saad ◽  
Rania El Hossany ◽  
Tarek El Gohary ◽  
Mohamed El Ghobashy

BACKGROUND: Weaning from invasive mechanical ventilation (MV) is considered as a daily challenging practice in the management of critically ill patients. The use of lung ultrasound and change in haemoglobin and hematocrit during weaning may help to predict weaning outcomes. AIM: We aimed in our study to make a focused view over the changes occurred in lungs during weaning from MV which were detected by lung ultrasound through increase in B lines with the occurrence of weaning induced pulmonary oedema (WIPE), coinciding with this changes the occurrence of hemoconcentration was detected through increase in Hb and HCT values after SBT. PATIENTS AND METHODS: Sixty patients who fulfilled readiness criteria for weaning from MV. Spontaneous breathing trial (SBT) on T-piece for 120 minutes was performed under close hemodynamic monitoring. Lung ultrasound was performed using eight lung zones protocol to detect both the presence and the trend of change in B lines before and after SBT. For all the studied patients, haemoglobin and hematocrit values were checked just before and at the end of SBT. RESULTS: Patient who failed to pass SBT showed significant increase in lung segments showing B pattern, haemoglobin and hematocrit levels (p-value < 0.001 for all) also those patients had significantly higher duration of ICU stay (p-value < 0.001) Despite mortality rate was higher among patients who failed SBT yet it was statistically insignificant (p-value 0.104). CONCLUSION: lung ultrasound and both haemoglobin and hematocrit levels correlate with weaning outcomes.


2021 ◽  
Vol 49 (5) ◽  
pp. 030006052110100
Author(s):  
Ju Gong ◽  
Bibo Zhang ◽  
Xiaowen Huang ◽  
Bin Li ◽  
Jian Huang

Objective Clinicians cannot precisely determine the time for withdrawal of ventilation. We aimed to evaluate the performance of driving pressure (DP)×respiratory rate (RR) to predict the outcome of weaning. Methods Plateau pressure (Pplat) and total positive end-expiratory pressure (PEEPtot) were measured during mechanical ventilation with brief deep sedation and on volume-controlled mechanical ventilation with a tidal volume of 6 mL/kg and a PEEP of 0 cmH2O. Pplat and PEEPtot were measured by patients holding their breath for 2 s after inhalation and exhalation, respectively. DP was determined as Pplat minus PEEPtot. The rapid shallow breathing index was measured from the ventilator. The highest RR was recorded within 3 minutes during a spontaneous breathing trial. Patients who tolerated a spontaneous breathing trial for 1 hour were extubated. Results Among the 105 patients studied, 44 failed weaning. During ventilation withdrawal, DP×RR was 136.7±35.2 cmH2O breaths/minute in the success group and 230.2±52.2 cmH2O breaths/minute in the failure group. A DP×RR index >170.8 cmH2O breaths/minute had a sensitivity of 93.2% and specificity of 88.5% to predict failure of weaning. Conclusions Measurement of DP×RR during withdrawal of ventilation may help predict the weaning outcome. A high DP×RR increases the likelihood of weaning failure. Statement: This manuscript was previously posted as a preprint on Research Square with the following link: https://www.researchsquare.com/article/rs-15065/v3 and DOI: 10.21203/rs.2.24506/v3


2020 ◽  
Vol 8 (1) ◽  
pp. 50-50
Author(s):  
Seyed Hossein Ojaghi Haghighi ◽  
Neda Hamed ◽  
Shiva Ebrahimi ◽  
Jafar Ghobadi ◽  
Hoorolnesa Ameli

Introduction: Congestive heart failure is heart muscle failure that causes pulmonary congestion and eventually pulmonary edema, which despite recent medical advances, is still a progressive syndrome with high mortality, the prevalence of which has increased in recent decades. Therefore, in this study we compared lung ultrasound findings in acute heart failure patients with the BNP. Methods: This study was performed in the emergency room of Imam Reza hospital in Tabriz. For patients entering the emergency room after taking a history, both standard gold (BNP) tests and beside ultrasound of the lung were performed. Ultrasound was performed at the same time as obtaining blood sample to ensure that the ultrasound specialist did not know the result of diagnosis. During the ultrasound, if there were multiple B-Lines that were at least 3 mm apart, patient was diagnosed with pulmonary edema due to heart failure. Results: Number of participants in this study was 108 people, 54.6% of whom were men and the rest were women. The correlation coefficient between width and number of kerley lines was 0.79, between NT-pro BNP and width of kerley lines was 0.65 and between NT-pro BNP and number of kerley lines was 0.77, which indicates a significant positive correlation (P value <0.001). Conclusion: The results of present study showed that in patients with acute heart failure, the number and width of kerley lines in pulmonary ultrasound evaluation increase rapidly. There is also a high correlation between number and length of kerley lines with NT-pro BNP serum values.


2018 ◽  
Vol 2 (S1) ◽  
pp. 30-31
Author(s):  
Emily M. Evans ◽  
Rebecca J. Doctor ◽  
Brian M. Fuller ◽  
Richard S. Hotchkiss ◽  
Anne M. Drewry

OBJECTIVES/SPECIFIC AIMS: (1) To evaluate clinical outcomes in mechanically ventilated patients with and without fever. We hypothesize that, after adjusting for confounding factors such as age and severity of illness: (a) In septic patients, fever will be associated with improved clinical outcomes. (b) In nonseptic patients, fever will be associated with worse clinical outcomes. (2) To examine the relationship between antipyretics and mortality in mechanically ventilated patients at risk for an acute lung injury. We hypothesize that antipyretics will have no effect on clinical outcomes in mechanically ventilated patients with and without sepsis. METHODS/STUDY POPULATION: This is a retrospective study of a “before and after” observational cohort of 1705 patients with acute initiation of mechanical ventilation in the Emergency Department from September 2009 to March 2016. Data were collected retrospectively on the first 72 hours of temperature and antipyretic medication from the EHR. Temperatures measurements were adjusted based on route of measurement. Patients intubated for cardiac arrest or brain injury were excluded from our primary analysis due to the known damage of hyperthermia in these subsets. Cox proportional hazard models and multivariable linear regression analyzed time-to-event and continuous outcomes, respectively. Predetermined patient demographics were entered into each multivariable model using backward and forward stepwise regression. Models were assessed for collinearity and residual plots were used to assure each model met assumptions. RESULTS/ANTICIPATED RESULTS: Antipyretic administration is currently undergoing analysis. Initial temperature results are reported here. In the overall group, presence of hypothermia or fever within 72 hours of intubation compared with normothermia conferred a hazard ratio (HR) of 1.95 (95% CI: 1.48–2.56) and 1.31 (95% CI: 0.97–1.78), respectively. Presence of hypothermia and fever reduced hospital free days by 3.29 (95% CI: 2.15–4.42) and 2.34 (95% CI: 1.21–3.46), respectively. In our subgroup analysis of patients with sepsis, HR for 28-day mortality 2.57 (95% CI: 1.68–3.93) for hypothermia. Fever had no effect on mortality (HR 1.11, 95% CI: 0.694–1.76). Both hypothermia and fever reduced hospital free days by 5.39 (95% CI: 4.33–7.54) and 3.98 (95% CI: 2.46–5.32) days, respectively. DISCUSSION/SIGNIFICANCE OF IMPACT: As expected, both hypothermia and fever increased 28-day mortality and decreased hospital free days. In our sepsis subgroup, hypothermia again resulted in higher mortality and fewer hospital free days, while fever did not have a survival benefit or cost, but reduced hospital free days. Antipyretic administration complicates these findings, as medication may mask fever or exert an effect on survival. Fever may also affect mechanically ventilated septic patients differently than septic patients not on mechanical ventilation. Continued analysis of this data including antipyretic administration, ventilator free days and progression to ARDS will address these questions.


2013 ◽  
Vol 41 (8) ◽  
pp. e182-e185 ◽  
Author(s):  
Silvia Mongodi ◽  
Gabriele Via ◽  
Belaïd Bouhemad ◽  
Enrico Storti ◽  
Francesco Mojoli ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document