The newborn hearing screening results in Kastamonu Education and Research Hospital

2021 ◽  
pp. 63-66

Purpose: The purpose of this study is to report the results of newborn hearing screening performed in 2017-2020 at the Kastamonu Education and Research Hospital, Turkey. Material and Method: Six thousand seven hundred and ninety newborns undergoing hearing screening between January 2017 and December 2019 at the Kastamonu Education and Research Hospital were included in this retrospective study. The screening ABR test was performed with all babies. Test findings retrieved from our hospital and the central database were subjected to analysis. Results: 4701 babies passed the 1st test, 1920 babies passed the 2nd test, 139 babies passed the 3rd test. Of the 30 babies who could not pass these 3 screening ABR tests and were referred to the reference center, 19 passed the test. Of the remaining 11 babies (0.162%), 7 (0.103%) had unilateral sensorineural hearing loss (SNHL) and 4 (0.058%) had bilateral SNHL. Conclusion: It is very important for hearing loss to be detected via screening tests in the first three months and for treatment and rehabilitation to be started within six months at the latest. These babies can thus acquire normal hearing and not lag behind their peers in terms of linguistic, social, and cognitive skill development.

Author(s):  
Philippa Horn ◽  
Carlie Driscoll ◽  
Jane Fitzgibbons ◽  
Rachael Beswick

Purpose The current Joint Committee on Infant Hearing guidelines recommend that infants with syndromes or craniofacial abnormalities (CFAs) who pass the universal newborn hearing screening (UNHS) undergo audiological assessment by 9 months of age. However, emerging research suggests that children with these risk factors are at increased risk of early hearing loss despite passing UNHS. To establish whether earlier diagnostic audiological assessment is warranted for all infants with a syndrome or CFA, regardless of screening outcome, this study compared audiological outcomes of those who passed UNHS and those who referred. Method A retrospective analysis was performed on infants with a syndrome or CFA born between July 1, 2012, and June 30, 2017 who participated in Queensland, Australia's state-wide UNHS program. Results Permanent childhood hearing loss (PCHL) yield was higher among infants who referred on newborn hearing screening (51.20%) than in those who passed. Nonetheless, 27.47% of infants who passed were subsequently diagnosed with hearing loss (4.45% PCHL, 23.02% transient conductive), but PCHL was generally milder in this cohort. After microtia/atresia, the most common PCHL etiologies were Trisomy 21, other syndromes, and cleft palate. Of the other syndromes, Pierre Robin sequence featured prominently among infants who passed the hearing screen and were subsequently diagnosed with PCHL, whereas there was a broader mix of other syndromes that caused PCHL in infants who referred on screening. Conclusion Children identified with a syndrome or CFA benefit from early diagnostic audiological assessment, regardless of their newborn hearing screening outcome.


2021 ◽  
Vol 15 (6) ◽  
pp. 2067-2071
Author(s):  
Gholam-Ali Dashti Khavidaki ◽  
Reza Gharibi

Introduction: Hearing loss is one of the most common congenital disorders. The prevalence of this disorder in different communities has been reported between 3.5 to 9 percent, which can have adverse effects on language learning, communication, and education of children. Also, early diagnosis of this disorder in newborns is not possible without the use of hearing screening. Therefore, the aim of this study was to evaluate the effectiveness of newborn hearing screening programs in Zahedan. Method: In this cross-sectional observational study, all babies born in the maternity hospitals of Zahedan city (maternity hospitals of Nabi Akram, Imam Ali, and Social Security hospitals) in 2020, were examined. In order to conduct the study, TEOAE was initially performed for all neonates. Then, based on the results obtained in the ODA test and in case of unsatisfactory response, cases were referred for re-evaluation. Infants who were rejected again in the second stage were immediately subjected to the AABR test and if they failed in this test, they were also subjected to a diagnostic ABR test. Results: Based on our results, 7700 infants were first evaluated with the OAE test. Of these, 580 (8%) had no OAE response. Out of 580 infants rejected in the first stage, 76 infants were also rejected in the second stage; Among them, 8 infants were re-diagnosed with hearing impairments. Finally, out of 3 infants who were diagnosed with hearing loss, 1 (33%) had conductive hearing loss and 2 (67%) had sensorineural hearing loss. Conclusion: Based on the findings of the present study, the implementation of a comprehensive neonatal hearing screening program is necessary for the timely and early diagnosis and treatment of hearing loss. Also, screening can improve the health of children and their personal, social, and educational development in the future. Keywords: Hearing screening, hearing loss, newborns, OAE, AABR


2005 ◽  
Vol 48 (2) ◽  
pp. 135-141 ◽  
Author(s):  
Shoichiro Fukuda ◽  
Naomi Toida ◽  
Kunihiro Fukushima ◽  
Yuko Kataoka ◽  
Kazunori Nishizaki

2019 ◽  
Vol 29 (Supplement_4) ◽  
Author(s):  
A Doncarli ◽  
H Tillaut ◽  
V Goulet

Abstract Background The French newborn hearing screening programme set up in 2014 aims to identify affected children as early as possible to allow appropriate care. Our goal was to evaluate the implementation of this programme at the national level. Methods The programme consist in a screening using a test (T1) and a retest (T2) in the maternity hospital in all newborns. In some region, a delayed test (T3) is performed afterwards in children for whom it was not possible to confirm normal hearing. Children suspected of deafness subsequently enter the diagnosis phase. We defined evaluation indicators after stakeholders consultation. We developed a web application to collect aggregated data on live births. We estimated the rate of coverage, refusal, children suspected of hearing loss at the end of the screening phase and the prevalence of bilateral deafness. Results In 2015, one year after the initiation of the programme, the coverage rate was already very high (88%) and even more so in 2016 (96%). Parental acceptance was very good (refusal: 0.1%). By the end of 2016, 19 out 27 regions had added a T3. The rate of suspicion of bilateral hearing loss was decreased by using a T3 (1.4% vs 0.9%). Bilateral deafness rate, estimated after a 2-years follow up, was 1.3‰ although it was estimated only on 51.5% of suspected children for whom diagnosis data had been transmitted. Conclusions The objective of a 90% coverage set by the French ministry of health has been met after 2 years of operation of the program. T3 appears useful in relieving diagnostic structures from false positives. Our estimated prevalence of bilateral deafness could be more accurate if data collection was improved but is consistent with prevalence reported in North America. Key messages The universal newborn hearing screening program has been successfully set up in France in terms of coverage. Future work should focus on improving the collection of follow up data to better characterise diagnosed children.