scholarly journals Study on the Stability of Cantilevered Pipe Conveying Fluid Subjected to Distributed Follower Force

Author(s):  
C. Semler ◽  
M. P. Païdoussis

Abstract This paper deals with the nonlinear dynamics and the stability of cantilevered pipes conveying fluid, where the fluid has a harmonic component of flow velocity, assumed to be small, superposed on a constant mean value. The mean flow velocity is near the critical value for which the pipe becomes unstable by flutter through a Hopf bifurcation. The partial differential equation is transformed into a set of ordinary differential equations (ODEs) using the Galerkin method. The equations of motion contain nonlinear inertial terms, and hence cannot be put into standard form for numerical integration. Various approaches are adopted to tackle the problem: (a) a perturbation method via which the nonlinear inertial terms are removed by finding an equivalent term using the linear equation; the system is then put into first-order form and integrated using a Runge-Kutta scheme; (b) a finite difference method based on Houbolt’s scheme, which leads to a set of nonlinear algebraic equations that is solved with a Newton-Raphson approach; (c) the stability boundaries are obtained using an incremental harmonic balance method as proposed by S.L. Lau. Using the three methods, the dynamics of the pipe conveying fluid is investigated in detail. For example, the effects of (i) the forcing frequency, (ii) the perturbation amplitude, and (iii) the flow velocity are considered. Particular attention is paid to the effects of the nonlinear terms. These results are compared with experiments undertaken in our laboratory, utilizing elastomer pipes conveying water. The pulsating component of the flow is generated by a plunger pump, and the motions are monitored by a noncontacting optical follower system. It is shown, both numerically and experimentally, that periodic and quasiperiodic oscillations can exist, depending on the parameters.


2000 ◽  
Vol 68 (2) ◽  
pp. 206-212 ◽  
Author(s):  
I. Elishakoff ◽  
N. Impollonia

The effect of the elastic Winkler and rotatory foundations on the stability of a pipe conveying fluid is investigated in this paper. Both elastic foundations are partially attached to the pipe. It turns out that the single foundation, either translational or rotatory, which is attached to the pipe along its entire length, increases the critical velocity. Such an intuitively anticipated strengthening effect is surprisingly missing for the elastic column on Winkler foundation subjected to the so-called statically applied follower forces. Yet, partial foundation for the pipe conveying fluid is associated with a nonmonotonous dependence of the critical velocity versus the attachment ratio defined as the length of the partial foundation over the entire length of the pipe. It is concluded that such a paradoxical nonmonotonicity is shared by both the realistic structure (pipe conveying fluid) and in the “imagined system,” to use the terminology of Herrmann pertaining to the column under to follower forces.


2022 ◽  
Vol 12 (2) ◽  
pp. 724
Author(s):  
Zilong Guo ◽  
Qiao Ni ◽  
Lin Wang ◽  
Kun Zhou ◽  
Xiangkai Meng

A cantilevered pipe conveying fluid can lose stability via flutter when the flow velocity becomes sufficiently high. In this paper, a dry friction restraint is introduced for the first time, to evaluate the possibility of improving the stability of cantilevered pipes conveying fluid. First, a dynamical model of the cantilevered pipe system with dry friction is established based on the generalized Hamilton’s principle. Then the Galerkin method is utilized to discretize the model of the pipe and to obtain the nonlinear dynamic responses of the pipe. Finally, by changing the values of the friction force and the installation position of the dry friction restraint, the effect of dry friction parameters on the flutter instability of the pipe is evaluated. The results show that the critical flow velocity of the pipe increases with the increment of the friction force. Installing a dry friction restraint near the middle of the pipe can significantly improve the stability of the pipe system. The vibration of the pipe can also be suppressed to some extent by setting reasonable dry friction parameters.


2019 ◽  
Vol 98 (4) ◽  
pp. 2927-2938 ◽  
Author(s):  
Kiyotaka Yamashita ◽  
Takahiro Yagyu ◽  
Hiroshi Yabuno

2001 ◽  
Vol 2001 (0) ◽  
pp. 175-176
Author(s):  
Hitoshi DOKI ◽  
Kazuhiko HIRAMOTO ◽  
Tomomichi MIYAZAKI ◽  
Motohiro MISHIMA

Sign in / Sign up

Export Citation Format

Share Document