scholarly journals Condition Monitoring for Air Filters in HVAC Systems with Variable Volume Flow

Author(s):  
Oliver Gnepper ◽  
Olaf Enge-Rosenblatt
2021 ◽  
Author(s):  
Jason S Hoffman ◽  
Matthew Hirano ◽  
Nuttada Panpradist ◽  
Joseph Breda ◽  
Parker Ruth ◽  
...  

Affordably tracking the transmission of respiratory infectious diseases in urban transport infrastructures can inform individuals about potential exposure to diseases and guide public policymakers to prepare timely responses based on geographical transmission in different areas in the city. Towards that end, we designed and tested a method to detect SARS-CoV-2 RNA in the air filters of public buses, revealing that air filters could be used as passive fabric sensors for the detection of viral presence. We placed and retrieved filters in the existing HVAC systems of public buses to test for the presence of trapped SARS-CoV-2 RNA using phenol-chloroform extraction and RT-qPCR. SARS-CoV-2 RNA was detected in 14% (5/37) of public bus filters tested in Seattle, Washington, from August 2020 to March 2021. These results indicate that this sensing system is feasible and that, if scaled, this method could provide a unique lens into the geographically relevant transmission of SARS-CoV-2 through public transit rider vectors, pooling samples of riders over time in a passive manner without installing any additional systems on transit vehicles.


Author(s):  
Saeed Moaveni ◽  
Patrick A. Tebbe ◽  
Louis Schwartzkopf ◽  
Joseph Dobmeier ◽  
Joseph Gehrke ◽  
...  

In this paper, we will present a method for estimating the stored thermal energy in a building wall that is adjacent to an unglazed transpired collector. We also discuss how this value should be incorporated in the collector efficiency calculations. An unglazed transpired collector is made of a relatively thin, dark, perforated metal wall that is installed approximately 14 inches (35.5 cm) away from a south facing building wall to create an enclosed plenum. Typically, the outside air is drawn into the collector by fans that are located on the top of the collector. These types of solar collectors are used to preheat the intake air using solar energy before the air enters existing HVAC systems. They are generally used in situations and buildings where large ventilation volume flow rates are required. Most of the studies related to unglazed transpired collectors deal with estimation of air temperature rise due to solar gain and recaptured heat loss from the adjoining building wall. In the past, studies have neglected the amount of thermal energy that is stored in the building wall. However, as shown in this study, the stored thermal energy is of significant amount, and if incorporated correctly in the collector efficiency calculations, it would lead to higher efficiency values.


Author(s):  
Joe A. Mascorro ◽  
Gerald S. Kirby

Embedding media based upon an epoxy resin of choice and the acid anhydrides dodecenyl succinic anhydride (DDSA), nadic methyl anhydride (NMA), and catalyzed by the tertiary amine 2,4,6-Tri(dimethylaminomethyl) phenol (DMP-30) are widely used in biological electron microscopy. These media possess a viscosity character that can impair tissue infiltration, particularly if original Epon 812 is utilized as the base resin. Other resins that are considerably less viscous than Epon 812 now are available as replacements. Likewise, nonenyl succinic anhydride (NSA) and dimethylaminoethanol (DMAE) are more fluid than their counterparts DDSA and DMP- 30 commonly used in earlier formulations. This work utilizes novel epoxy and anhydride combinations in order to produce embedding media with desirable flow rate and viscosity parameters that, in turn, would allow the medium to optimally infiltrate tissues. Specifically, embeding media based on EmBed 812 or LX 112 with NSA (in place of DDSA) and DMAE (replacing DMP-30), with NMA remaining constant, are formulated and offered as alternatives for routine biological work.Individual epoxy resins (Table I) or complete embedding media (Tables II-III) were tested for flow rate and viscosity. The novel media were further examined for their ability to infilftrate tissues, polymerize, sectioning and staining character, as well as strength and stability to the electron beam and column vacuum. For physical comparisons, a volume (9 ml) of either resin or media was aspirated into a capillary viscocimeter oriented vertically. The material was then allowed to flow out freely under the influence of gravity and the flow time necessary for the volume to exit was recored (Col B,C; Tables). In addition, the volume flow rate (ml flowing/second; Col D, Tables) was measured. Viscosity (n) could then be determined by using the Hagen-Poiseville relation for laminar flow, n = c.p/Q, where c = a geometric constant from an instrument calibration with water, p = mass density, and Q = volume flow rate. Mass weight and density of the materials were determined as well (Col F,G; Tables). Infiltration schedules utilized were short (1/2 hr 1:1, 3 hrs full resin), intermediate (1/2 hr 1:1, 6 hrs full resin) , or long (1/2 hr 1:1, 6 hrs full resin) in total time. Polymerization schedules ranging from 15 hrs (overnight) through 24, 36, or 48 hrs were tested. Sections demonstrating gold interference colors were collected on unsupported 200- 300 mesh grids and stained sequentially with uranyl acetate and lead citrate.


Sign in / Sign up

Export Citation Format

Share Document