Twenty Years of Experience in Management of Intussusception: Saline Enema Reduction with Ultrasound Guidance

Author(s):  
Saied Aslanabadi ◽  
Davoud Badebarin ◽  
Nazila Hasanzadeh Ghavifekr ◽  
Sina Aslanabadi ◽  
Sina Zarrintan ◽  
...  
Author(s):  
Georgios Zenonos ◽  
Kenan Alkhalili ◽  
Maria Koutourousiou ◽  
Nathan Zwagerman ◽  
David Panczykowski ◽  
...  

1988 ◽  
Vol 60 (01) ◽  
pp. 039-043 ◽  
Author(s):  
L Mandelbrot ◽  
M Guillaumont ◽  
M Leclercq ◽  
J J Lefrère ◽  
D Gozin ◽  
...  

SummaryVitamin K status was evaluated using coagulation studies and/ or vitamin IQ assays in a total of 53 normal fetuses and 47 neonates. Second trimester fetal blood samples were obtained for prenatal diagnosis under ultrasound guidance. Endogenous vitamin K1 concentrations (determined by high performance liquid chromatography) were substantially lower than maternal levels. The mean maternal-fetal gradient was 14-fold at mid trimester and 18-fold at birth. Despite low vitamin K levels, descarboxy prothrombin, detected by a staphylocoagulase assay, was elevated in only a single fetus and a single neonate.After maternal oral supplementation with vitamin K1, cord vitamin K1 levels were boosted 30-fold at mid trimester and 60 fold at term, demonstrating placental transfer. However, these levels were substantially lower than corresponding supplemented maternal levels. Despite elevated vitamin K1 concentrations, supplemented fetuses and neonates showed no increase in total or coagulant prothrombin activity. These results suggest that the low prothrombin levels found during intrauterine life are not due to vitamin K deficiency.


1969 ◽  
Vol 62 (1_Suppl) ◽  
pp. S113-S133 ◽  
Author(s):  
Sam Brody

ABSTRACT This report is a summary of 10 years of experience with the complement fixation test as adopted for the immunoassay of HCG in serum. It is based on published as well as unpublished material. The discussion centers mainly around methodological problems, criteria of reliability, and clinical observations. It is our impression that the complement fixation test is a reasonably rapid and simple technical procedure. It is standard practice in every bacteriological and virological laboratory. The precision of the HCG assay is high. Its accuracy is good. The complement fixation assay, as reported here, fulfils the criteria of specificity. It has been evaluated by means of serological techniques and through comparison between biopotency and immunopotency of HCG in serum with reference to a common standard. Its application for routine as well as research work is illustrated.


Sign in / Sign up

Export Citation Format

Share Document