scholarly journals The Effect of Service Installations on Structural Integrity of Slabs in Buildings

2010 ◽  
Vol 33 (1) ◽  
pp. 18-28
Author(s):  
Ladslaus Lwambuka

In building construction industry service installations, usually housed in conduit pipes, are commonly mounted inside reinforced concrete structural elements. This practice is adopted to attain aesthetical outlook at both interior and exterior surfaces of the buildings. Depending on the extent of service installations, the cross sectional area of the load bearing structural member is substantially reduced. However, the current structural design guidelines have no provision to accommodate the extent to which the existence of conduit pipes impairs the load bearing capacity of the structural element though reduced cross sectional area. This study has attempted to address this gap in structural design ofbuildings; it involves assessing the current design practice of considering a structural element as a full solid body and comparing its ultimate load bearing capacity with the ones containing the conduit pipes. The study findings are based on test results from laboratory experiments on reinforced concrete slab models with varying intensity of conduit pipeinstallations as commonly practiced on construction sites. Recommendations are put forth when and how to consider the reduced load bearing capacity through the existence of service installations as part of structural engineering designs.

Author(s):  
Jan Krejsa ◽  
Miroslav Sýkora

Abstract This paper is focused on the reliability analysis of an existing reinforced concrete bridge from 1908. The load bearing capacity is assessed in accordance with valid standards using updated partial factors and the partial factors for structural design. Load bearing capacities obtained by these methods are critically compared. The application of the updated partial factors leads to 15% higher load bearing capacity than the ordinary partial factor method used for structural design.


2017 ◽  
Vol 68 (1) ◽  
pp. 94-100
Author(s):  
Oana Tanculescu ◽  
Adrian Doloca ◽  
Raluca Maria Vieriu ◽  
Florentina Mocanu ◽  
Gabriela Ifteni ◽  
...  

The load-bearing capacity and fracture pattern of direct inlay-retained FRC FDPs with two different cross-sectional designs of the ponticwere tested. The aim of the study was to evaluate a new fibre disposition. Two types of composites, Filtek Bulk Fill Posterior Restorative and Filtek Z250 (3M/ESPE, St. Paul, MN, USA), and one braided polyethylene fibre, Construct (Kerr, USA) were used. The results of the study suggested that the new tested disposition of the fibres prevented in some extend the delamination of the composite on buccal and facial sides of the pontic and increased the load-bearing capacity of the bridges.


2020 ◽  
Vol 23 (11) ◽  
pp. 2276-2291
Author(s):  
Rui Pang ◽  
Yibo Zhang ◽  
Longji Dang ◽  
Lanbo Zhang ◽  
Shuting Liang

This article proposes a new type of discrete connected precast reinforced concrete diaphragm floor system that consists of precast flat slabs and slab joint connectors. An experimental investigation of discrete connected new-type precast reinforced concrete diaphragm under a vertical distributed static load was conducted, and the effect of slab joint connectors on the load-bearing capacity was evaluated. Then, a finite element analysis of discrete connected new-type precast reinforced concrete diaphragm, precast reinforced concrete floors without slab connectors, and cast-in-situ reinforced concrete floor were performed to understand their working mechanism and determine the differences in load-bearing behavior. The results indicate that the load-bearing capacity and stiffness of discrete connected new-type precast reinforced concrete diaphragm increase considerably as the hairpin and cover plate hybrid slab joint connectors can efficiently connect adjacent precast slabs and enable them to work together under a vertical load by transmitting the shear and moment forces in the orthogonal slab laying direction. The deflection of discrete connected new-type precast reinforced concrete diaphragm in orthogonal slab laying direction is mainly caused by the opening deformation of the slab joint and the rotational deformation of the precast slabs. This flexural deformation feature can provide reference for establishing the bending stiffness analytical model of discrete connected new-type precast reinforced concrete diaphragm in orthogonal slab laying direction, which is vitally important for foundation of the vertical bearing capacity and deformation calculation method. The deflection and crack distribution patterns infer that the discrete connected new-type precast reinforced concrete diaphragm processes the deformation characteristic of two-way slab floor, which can provide a basis for the theoretical analysis of discrete connected new-type precast reinforced concrete diaphragm.


2019 ◽  
Vol 97 ◽  
pp. 04059 ◽  
Author(s):  
Alexey Dem’yanov ◽  
Vladymir Kolchunov ◽  
Igor Iakovenko ◽  
Anastasiya Kozarez

It is presented the formulation and solution of the load bearing capacity of statically indeterminable systems “reinforced concrete beam – deformable base” by spatial cross-sections under force and deformation effects. The solution of problem is currently practically absent in general form. It has been established the relationship between stresses and strains of compressed concrete and tensile reinforcement in the form of diagrams. The properties of the base model connections are described based on a variable rigidity coefficient. It is constructed a system of n equations in the form of the initial parameters method with using the modules of the force (strain) action vector. The equations of state are the dependences that establish the relationship between displacements which are acting on the beam with load. Constants of integration are determined by recurrent formulas. It makes possible to obtain the method of initial parameters in the expanded form and, consequently, the method of displacements for calculating statically indefinable systems. The values of the effort obtained could be used to determine the curvature and rigidity of the sections in this way. It is necessary not to set the vector modulusP, the deformation is set in any section (the module is considered as an unknown) during the problem is solving. This allows us to obtain an unambiguous solution even in the case when the dependence M–χ has a downward section, i.e one value of moment can correspond to two values of curvature.


2021 ◽  
Vol 5 (2) ◽  
pp. 49
Author(s):  
Andreas Hetzel ◽  
Robert Schulte ◽  
Manfred Vogel ◽  
Michael Lechner ◽  
Hans-Bernward Besserer ◽  
...  

Due to rising demands regarding the functionality and load-bearing capacity of functional components such as synchronizer rings in gear systems, conventional forming operations are reaching their limits with respect to formability and efficiency. One way to meet these challenges is the application of the innovative process class of sheet-bulk metal forming (SBMF). By applying bulk forming operations to sheet metal, the advantages of both process classes can be combined, thus realizing an optimized part weight and an adapted load-bearing capacity. Different approaches to manufacturing relevant part geometries were presented and evaluated regarding the process properties and applicability. In this contribution, a self-learning engineering workbench was used to provide geometry-based data regarding a novel component geometry with circumferential involute gearing manufactured in an SBMF process combination of deep drawing and upsetting. Within the comprehensive investigations, the mechanical and geometrical properties of the part were analyzed. Moreover, the manufactured components were compared regarding the increased fatigue strength in cyclic load tests. With the gained experimental and numerical data, the workbench was used for the first time to generate the desired component as a CAD model, as well as to derive design guidelines referring to the investigated properties and fatigue behavior.


2016 ◽  
Vol 821 ◽  
pp. 767-773
Author(s):  
Jan Krejsa ◽  
Miroslav Sýkora ◽  
Michal Drahorád

This paper is aimed at the reliability analysis of an existing reinforced concrete bridge from 1908. The load bearing capacity is assessed in accordance with valid standards using the partial factor method and probabilistic approach. Load bearing capacities obtained by these methods are critically compared. The application of probabilistic method leads to 40 % higher load bearing capacity then the partial factor method used for structural design.


Sign in / Sign up

Export Citation Format

Share Document