1-stage bilateral total hip arthroplasty operation in 22 patients with use of short and standard stem length on either side: gait analysis 1 and 2 years after bilateral THA

2017 ◽  
Vol 28 (4) ◽  
pp. 391-399 ◽  
Author(s):  
Roland Zügner ◽  
Roy Tranberg ◽  
Goran Puretic ◽  
Johan Kärrholm

Background: According to previous gait analyses, insertion of a total hip arthroplasty (THA) will improve the range of hip flexion-extension but not to normal. Use of short stems could have a potential to improve the motion by preservation of more bone and muscular attachments. We evaluated whether a short femoral stem resulted in improved hip motion compared to a conventional stem in patients who underwent 1-stage bilateral THA. The most painful hip was randomised to either design and the 2nd hip was operated with the design not used on the 1st side. Methods: Gait analysis was performed with an optical tracking system in 22 patients. The follow-up was performed 1 and 2 years after the operation. The mean age was 59 (SD 7.7) years and body mass index was 27.7 (SD 4.3). 66 subjects without hip pathology served as controls. Results: Minimal differences were observed, between or within the 2 different stem designs during gait at the 2 follow-up occasions. Comparison between each of the 2 stem designs and controls at 2 years revealed reduced stride length (p = 0.009), cadence, hip extension (p<0.001) and hip extension-flexion range (p = 0.021) for both designs. Furthermore, the range of hip adduction-abduction (p = 0.046) and hip abduction moment for both designs in the frontal plane was also reduced bilaterally (p<0.001). Conclusions: We found no difference in gait parameters between the short and the conventional stem after 1-stage bilateral THA. Although both hip joints were operated at the same time motions and moments did not normalise after bilateral 1-stage operations.

Author(s):  
Anatole Vilhelm Wiik ◽  
Adeel Aqil ◽  
Bilal Al-Obaidi ◽  
Mads Brevadt ◽  
Justin Peter Cobb

Abstract Aim The length of the femoral stem in total hip arthroplasty (THA) is a practical consideration to prevent gait impairment. The aim of this study was to determine if reducing the femoral stem length in THA would lead to impaired gait biomechanics. Methods Patients uniformly with the same brand implant of differing lengths (100 mm vs 140–166 mm) were taken retrospectively from a prospective trial introducing a new short stem. Twelve patients without any other disorder to alter gait besides contralateral differing length stem THA were tested at differing gradients and speed on a validated instrumented treadmill measuring ground reaction forces. An anthropometrically similar group of healthy controls were analysed to compare. Results With the same posterior surgical approach, the offset and length of both hips were reconstructed within 5 mm of each other with an identical mean head size of 36 mm. The short stem was the last procedure for all the hips with gait analysis occurring at a mean of 31 and 79 months postoperatively for the short and long stem THA, respectively. Gait analysis between limbs of both stem lengths demonstrated no statistical difference during any walking condition. In the 90 gait assessments with three loading variables, the short stem was the favoured side 51% of the time compared 49% for the long stem. Conclusion By testing a range of practical walking activities, no lower limb loading differences can be observed by reducing the femoral stem length. A shorter stem demonstrates equivalence in preference during gait when compared to a reputable conventional stem in total hip arthroplasty.


2020 ◽  
Vol 102-B (2) ◽  
pp. 191-197 ◽  
Author(s):  
Jonathan A. Gabor ◽  
Jorge A. Padilla ◽  
James E. Feng ◽  
Erik Schnaser ◽  
William B. Lutes ◽  
...  

Aims Although good clinical outcomes have been reported for monolithic tapered, fluted, titanium stems (TFTS), early results showed high rates of subsidence. Advances in stem design may mitigate these concerns. This study reports on the use of a current monolithic TFTS for a variety of indications. Methods A multi-institutional retrospective study of all consecutive total hip arthroplasty (THA) and revision total hip arthroplasty (rTHA) patients who received the monolithic TFTS was conducted. Surgery was performed by eight fellowship-trained arthroplasty surgeons at four institutions. A total of 157 hips in 153 patients at a mean follow-up of 11.6 months (SD7.8) were included. Mean patient age at the time of surgery was 67.4 years (SD 13.3) and mean body mass index (BMI) was 28.9 kg/m2 (SD 6.5). Outcomes included intraoperative complications, one-year all-cause re-revisions, and subsidence at postoperative time intervals (two weeks, six weeks, six months, nine months, and one year). Results There were eight intraoperative complications (4.9%), six of which were intraoperative fractures; none occurred during stem insertion. Six hips (3.7%) underwent re-revision within one year; only one procedure involved removal of the prosthesis due to infection. Mean total subsidence at latest follow-up was 1.64 mm (SD 2.47). Overall, 17 of 144 stems (11.8%) on which measurements could be performed had >5 mm of subsidence, and 3/144 (2.1%) had >10 mm of subsidence within one year. A univariate regression analysis found that additional subsidence after three months was minimal. A multivariate regression analysis found that subsidence was not significantly associated with periprosthetic fracture as an indication for surgery, the presence of an extended trochanteric osteotomy (ETO), Paprosky classification of femoral bone loss, stem length, or type of procedure performed (i.e. full revision vs conversion/primary). Conclusion Advances in implant design, improved trials, a range of stem lengths and diameters, and high offset options mitigate concerns of early subsidence and dislocation with monolithic TFTS, making them a valuable option for femoral revision. Cite this article: Bone Joint J 2020;102-B(2):191–197.


2021 ◽  
pp. 112070002110184
Author(s):  
Andrey A Korytkin ◽  
Younes M El Moudni ◽  
Yana S Novikova ◽  
Kirill A Kovaldov ◽  
Ekaterina A Morozova

Background: The supercapsular percutaneously-assisted total hip (SuperPATH) approach is a muscle sparing surgical technique for total hip arthroplasty (THA). The literature reports good clinical and functional results of the SuperPATH technique in the short term. We aimed to compare early outcomes and gait analysis of THA using the mini posterior approach (MPA) and supercapsular percutaneously-assisted total hip (SuperPATH) approach. Methods: 44 patients who underwent THA, were randomly allocated to either MPA or SuperPATH. The data were then collected prospectively (preoperatively and postoperatively at 6 weeks). Plain anteroposterior radiographs of the pelvis and instrumental gait analysis were obtained. The visual analogue scale (VAS), Harris Hip Score (HHS) and Hip disability and Osteoarthritis Outcome Scores (HOOS) were used to assess functional and clinical outcomes. Results: No significant difference was found in patients’ surgical outcomes. Patients in the SuperPATH group had less pain according to the VAS score at follow-up than the MPA group ( p < 0.01). There was also a significant improvement in HHS and HOOS scores for all patients ( p < 0.001) with the SuperPATH group showing superior changes. The comparison of mean differences in gait velocity between preoperative and 6 weeks postoperative result, revealed improvement in the SuperPATH group over the MPA group ( p = 0.06). Limping was more persistent in the MPA group. Kinematic parameters demonstrated improved hip joint excursion slightly higher in the MPA group. There was no significant improvement in kinetic and kinematic parameters at different walking moments for all patients at 6 weeks compared to preoperative gait patterns. Conclusions: SuperPATH and MPA both show excellent results. This study reveals that the SuperPATH technique was associated with lower postoperative pain levels, and higher physical function and quality of life. Improved functional outcomes allowed earlier postoperative rehabilitation and faster recovery. Specific improvement in gait patterns were identified with nonsignificant differences between the 2 approaches at 6 weeks follow-up.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Jingyang Sun ◽  
Bohan Zhang ◽  
Lei Geng ◽  
Qingyuan Zheng ◽  
Juncheng Li ◽  
...  

Abstract Background Placement of femoral stem in excessive anteversion or retroversion can cause reduced range of motion, prosthetic impingement, and dislocation. The aim of this study was to assess the operative femoral anteversion in patients treated with total hip arthroplasty (THA) and analyze the need of adjusting stem anteversion. Methods We retrospectively included 101 patients (126 hips) who underwent cementless THA with a manual goniometer to determine the femoral anteversion between October 2017 and December 2018. The operative femoral anteversion we measured was recorded during THA. We further divided those hips into three subgroups based on the range of operative femoral anteversion: group 1 (<10°), group 2 (10–30°), and group 3 (>30°) and compared the differences of their demographic data. Univariate and multivariate logistic regression were used to identify the influencing factors for the need of neck-adjustable femoral stem. The clinical and radiographic outcomes were also assessed. Perioperative complications were recorded. Results After THA, the Harris hip scores improved from 52.87 ± 15.30 preoperatively to 90.04 ± 3.31 at the last follow-up (p < 0.001). No implant loosening, stem subsidence, and radiolucent lines were observed on radiographs. No severe complications occurred and no components needed revision at the latest follow-up. The mean operative femoral anteversion was 14.21° ± 11.80° (range, −9 to 60°). Patients with femoral anteversion more than 30° were about 10 years younger than others. Femoral anteversion >30° was more common in patients with developmental dysplasia of the hip (DDH). There were totally 14 hips treated with the neck-adjustable femoral stem. From the univariate analysis, we can observe that female sex, diagnosis of DDH (compared with osteonecrosis), and higher operative femoral anteversion and its value >30° (compared with <10°) are associated with higher rates of using the neck-adjustable femoral stem. However, all these factors were no longer considered as independent influencing factors when mixed with other factors. Conclusions This study highlighted the significance of operative femoral anteversion. Identification of abnormal femoral anteversion could assist in adjusting stem anteversion and reduce the risk of dislocation after THA.


Author(s):  
Anatole V. Wiik ◽  
Mads Brevadt ◽  
Hardeep Johal ◽  
Kartik Logishetty ◽  
Oliver Boughton ◽  
...  

2020 ◽  
Vol 102-B (11) ◽  
pp. 1491-1496
Author(s):  
Pranai K. Buddhdev ◽  
Ivor S. Vanhegan ◽  
Tahir Khan ◽  
Aresh Hashemi-Nejad

Aims Despite advances in the treatment of paediatric hip disease, adolescent and young adult patients can develop early onset end-stage osteoarthritis. The aims of this study were to address the indications and medium-term outcomes for total hip arthroplasty (THA) with ceramic bearings for teenage patients. Methods Surgery was performed by a single surgeon working in the paediatric orthopaedic unit of a tertiary referral hospital. Databases were interrogated from 2003 to 2017 for all teenage patients undergoing THA with a minimum 2.3 year follow-up. Data capture included patient demographics, the underlying hip pathology, number of previous surgeries, and THA prostheses used. Institutional ethical approval was granted to contact patients for prospective clinical outcomes and obtain up-to-date radiographs. In total, 60 primary hips were implanted in 51 patients (35 female, 16 male) with nine bilateral cases. The mean age was 16.7 years (12 to 19) and mean follow-up was 9.3 years (2.3 to 16.8). Results The most common indication for teenage hip arthroplasty was avascular necrosis secondary to slipped upper femoral epiphysis (31%; n = 16). Overall, 64% of patients (n = 33) had undergone multiple previous operations. The survival at follow-up was 97%; two patients required revision for aseptic loosening (one femoral stem, one acetabular component). Both patients had fused hips noted at the time of arthroplasty. A further two patients had radiolucent lines but were asymptomatic. At latest follow-up the mean Oxford Hip Score was 44 (31 to 48) and a Visual Analogue Scale measurement of 1.5, indicating satisfactory function. Conclusion Operating on this cohort can be complicated by multiple previous surgeries and distorted anatomy, which in some cases require custom-made prostheses. We have demonstrated a good outcome with low revision rate in this complex group of patients. Cite this article: Bone Joint J 2020;102-B(11):1491–1496.


2019 ◽  
pp. 112070001987738 ◽  
Author(s):  
Duncan W Cushnie ◽  
Brent A Lanting ◽  
Richard McCalden ◽  
Douglas DR Naudie ◽  
James L Howard

Introduction: Birmingham Hip Resurfacing (BHR) implants may be combined with a conventional femoral stem to create a modular metal-on-metal total hip arthroplasty (BHR MoM THA). There is little outcome data regarding this construct. This study examines midterm outcomes of BHR MoM THA compared to oxidised zirconium total hip arthroplasty (THA). Methods: A retrospective institutional review identified all patients receiving BHR MoM THA between April 2005 and February 2011 and a matched control cohort of zirconium THA patients. Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS), and SF-12 Health status scores were obtained. Revisions and complications were collected from clinical records. Radiographs were assessed for evidence of component malposition, loosening, osteolysis, or heterotopic ossification. Results: 63 modular BHR MoM THA were identified in 61 patients (36 with BHR cups, 27 with R3 cups) and 63 zirconium THA in 58 matched controls. Mean follow-up was 58 months. 14 BHR MoM THA hips (22.2%) were revised (4 infections, 1 dislocation, 9 soft tissue reactions) compared to 3 (4.8%) zirconium THA (all infections). At latest follow-up, 18.4% of surviving BHR MoM THA hips were painful compared to 0.5% of zirconium THA controls ( p < 0.001). WOMAC, HHS, and SF-12 did not differ significantly between surviving members of the 2 groups. Discussion: BHR MoM THA demonstrated a high revision rate, largely for adverse local soft tissue reaction and pain. Among those not revised, many reported some residual pain despite similar quality of life measures to those who received zirconium THA.


Sign in / Sign up

Export Citation Format

Share Document