RP-HPLC METHOD DEVELOPMENT AND ITS VALIDATION FOR EVALUATION OF POLYHERBAL FORMULATION

INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (10) ◽  
pp. 68-70
Author(s):  
K. Sankar ◽  
◽  
A. P. Jadhav

Curcumin and embelin, which are the active constituents of Haridra and Vidanga, respectively, were used as marker compounds for developing a simple, accurate, precise and robust RP-HPLC method for simultaneous estimation from Talekt capsule. It is a polyherbal formulation used for enhancing the immune response to dermal infections and also for treating skin disorders. The mobile phase of methanol: 1% ortho phosphoric acid in water in the ratio of 90:10 V/V was used for separation. Retention time of curcumin and embelin were found to be 2.77 ± 0.2 minutes and 7.77 ± 0.2 minutes, respectively. The developed method was validated as per ICH Q2 (R1) guidelines.

INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (10) ◽  
pp. 66-68
Author(s):  
◽  
A. P Jadhav

Talekt capsule is a branded polyherbal formulation used for enhancing the immune response to dermal infections and also for treating skin disorders. Curcumin and embelin, which are the active constituents of Haridra and Vidanga, respectively were used as marker compounds for developing a simple, accurate, precise and robust HPTLC method for simultaneous estimation. The mobile phase of toluene: ethyl acetate: formic acid (6.5: 3: 0.2 v/v/v) was used for separation. 381nm was used as wavelength for analysis. The Rf value obtained for curcumin, and embelin was found to be 0.51 ± 0.2 and 0.33 ± 0.2, respectively. The developed method was validated on the basis of ICH Q2 (R1) guidelines.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (05) ◽  
pp. 68-71
Author(s):  
A Lakshmana Rao ◽  
◽  
T. Prasanthi ◽  
E. L Anusha

A simple, accurate and precise RP-HPLC method was developed for the simultaneous estimation of the linagliptin and empagliflozin in tablet dosage form. Chromatogram was run through Kromasil 250 x 4.6 mM, 5mM column, mobile phase containing 0.1% o-phosphoric acid buffer and acetonitrile in the ratio of 60:40%v/v was pumped through column at a flow rate of 1 mL/min. The optimized wavelength was 230 nm. Retention times of linagliptin and empagliflozin were found to be 2.759 min and 2.139 min. %RSD of the Linagliptin and Empagliflozin were found to be 0.5 and 0.6 respectively. Percentage assay was obtained as 99.91% and 100.15% for linagliptin and empagliflozin, respectively. LOD, LOQ values obtained for linagliptin and empagliflozin were 0.23 μg/ml and 0.44 μg/mL and 0.70 μg/mL and 1.34 μg/mL, respectively. Thus, the current study showed that the developed RP-HPLC method is sensitive and selective for the estimation of linagliptin and empagliflozin in combined dosage form.


2018 ◽  
Vol 34 (5) ◽  
pp. 2554-2561
Author(s):  
D. China Babu ◽  
C. Madhusudhana Chetty ◽  
S. K. Mastanamma

A selective, sensitive RP-HPLC method was developed for the simultaneous estimation of the Ertugliflozin (ETR) and Sitagliptin (SGT) in bulk and its dosage form. The separation and determination was carried on water’s C18 column capacitate (250X4.6 mm, 5 µm particle size), retention times of Ertugliflozin and Sitagliptin were found to be 2.39 and 4.60 min respectively. The wavelength was fixed at 215nm with PDA detection. The mobile phase was consisted mixture of 0.5 mM potassium dihydrogen ortho phosphate buffer: Methanol in the ratio of 55:45 v/v, pH 5.3 was adjusted with HCl and flow of mobile phase was maintained 1mL/min. The calibration curve was linear and regression co-efficient (R2) value found to be 0.999 and concentration ranging from 37.5-112.5 and 250-750 µg/mL for Ertugliflozin & Sitagliptin respectively. The quantization limit and detection limit of the method were found 0.1 & 0.3 µg/ml and 0.4&1µg/ml for Ertugliflozin & Sitagliptin.


2012 ◽  
Vol 2012 ◽  
pp. 1-4 ◽  
Author(s):  
Shravan Bankey ◽  
Ganesh Tapadiya ◽  
Jasvant Lamale ◽  
Deepti Jain ◽  
Shweta Saboo ◽  
...  

A simple, accurate, and precise HPLC method was developed and validated for determination of rimonabant in human plasma. Following liquid-liquid extraction, chromatographic separation was accomplished using C18 column with mobile phase consisting of acetonitrile : water (90 : 10, v/v), drug was detected at 260 nm using UVdetector. The LOD and LOQ were 3.0 and 10.0 μg/L, respectively. The method is linear in the interval 50.0–1000.0 μg/L. The average extraction recovery of drug from plasma was found to be 92.2%. The percent CV of the method was found to be less than 10.8%, and accuracy was found between 94.5 and 106.7%. The assay may be applied to a pharmacokinetic and bioequivalence study of rimonabant.


2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Sadana Gangishetty ◽  
Surajpal Verma

The present work describes a simple, rapid, and reproducible reverse phase high performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of clarithromycin (CLA) and paracetamol (PCM). C18 column (Kromasil ODS, 5 µm, 250 × 4.6 mm) and a mobile phase containing phosphate buffer (0.05 M) along with 1-octane sulphonic acid sodium salt monohydrate (0.005 M) adjusted to pH 3.2: acetonitrile (50 : 50 v/v) mixture was used for the separation and quantification. The flow rate was 1.0 mL/min and the eluents were detected by UV detector at 205 nm. The retention times were found to be 2.21 and 3.73 mins, respectively. The developed method was validated according to ICH guidelines Q2 (R1) and found to be linear within the range of 75–175 µg/mL for both drugs. The developed method was applied successfully for assay of clarithromycin and paracetamol in their combined in-house developed dosage forms and in vitro dissolution studies.