scholarly journals Analysis for Shielding Effectiveness of an Enclosure with a Dielectric-B acted Rectangular Aperture

Author(s):  
Su-Han Kim ◽  
Jae-Hyun Lee
2019 ◽  
Vol 28 (4) ◽  
pp. 850-854
Author(s):  
Donglin SU ◽  
Hongyi LIU ◽  
Shunchuan YANG ◽  
Zihua ZHAO ◽  
Donghai SUI

1996 ◽  
Vol 32 (17) ◽  
pp. 1559 ◽  
Author(s):  
M.P. Robinson ◽  
J.D. Turner ◽  
D.W.P. Thomas ◽  
J.F. Dawson ◽  
M.D. Ganley ◽  
...  

2010 ◽  
Vol E93-C (6) ◽  
pp. 929-931 ◽  
Author(s):  
Yeong-Chul CHUNG ◽  
Kyung-Won LEE ◽  
Ic-Pyo HONG ◽  
Kyung-Hyun OH ◽  
Jong-Gwan YOOK

2020 ◽  
Vol 13 (1) ◽  
pp. 16
Author(s):  
Kukjoo Kim ◽  
Kyung-Ryeung Min ◽  
Young-Jun Park

The Korean peninsula is under increasing threat of electromagnetic pulses (EMPs) from neighboring countries; EMP protection facilities are an essential means of ensuring the operational readiness of the military. However, existing EMP protection facilities are manufactured as fixed-weight structures, which limit the mobility of military operations and lead to the misconception of EMP protection as something only required for higher command. The current military and official EMP protection standards require only a uniform shielding effectiveness of 80 dB. Therefore, this study aims to differentiate the existing uniform level of shielding effectiveness of 80 dB into 80 dB, 60 dB, 40 dB, etc. Further, it seeks to derive the factors to be considered when applying various methods, such as shielding rooms, shielding racks, site redundancy, spare equipment, and portable lightweight protective tents, for recovery of failure, instead of the existing protection facilities that rely on shielded rooms by the Delphi analysis. Then, the applicability of lightweight EMP protection is determined after selecting lightweight materials to build a facility. The electromagnetic shielding performance of 21 types of materials was measured in the 30 MHz–1.5 GHz frequency band using ASTM-D-4935-10. The results showed the possibility of developing a lightweight EMP shielding facility, which would save approximately 316,386 tons of concrete, reducing the CO2 emissions by approximately 9,972,489 tons. Assuming that the Korean carbon transaction price is USD 50/ton CO2, the savings are equivalent to USD 49,862,435.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Duy Tung Phan ◽  
Chang Won Jung

AbstractAn electromagnetic pulse (EMP) with high energy can damage electronic equipment instantly within a wide range of thousands of kilometers. Generally, a metal plate placed inside a thick concrete wall is used against an EMP, but it is not suitable for an EMP shielding window, which requires not only strong shielding effectiveness (SE) but also optical transparency (OT). In this paper, we propose a very thin and optically transparent structure with excellent SE for EMP shielding window application. The proposed structure consists of a saltwater layer held between two glass substrates and two metal mesh layers on the outside of the glass, with a total thickness of less than 1.5 cm. The SE and OT of the structure are above 80 dB and 45%, respectively, which not only meet the requirement of EMP shielding for military purposes but also retain the procedure of good observation. Moreover, the OT of the structure can be significantly improved using only one metal mesh film (MMF) layer, while the SE is still maintained high to satisfy the required SE for home applicants. With the major advantages of low cost, optical transparency, strong SE, and flexible performance, the proposed structure can be considered a good solution for transparent EMP shielding windows.


Sign in / Sign up

Export Citation Format

Share Document