scholarly journals Using Electrical Resistivity Tomography (ERT) to Delineate Subsurface Structures at Siloam Hot Spring in the Soutpansberg Basin, South Africa

2018 ◽  
Vol 10 (4) ◽  
pp. 19
Author(s):  
Peter K. Nyabeze ◽  
Oswald Gwavava ◽  
Matome Sekiba

Electrical resistivity tomography (ERT) was used to delineate subsurface structures at Siloam hot spring in the Soutpansberg Basin of South Africa. The spring water was reported to be hottest in South Africa. Groundwater with temperature ranging between 63.3 °C and 67.5°C was observed flowing from the spring. Relatively wet areas were noted to the south and north of the spring. Electrical resistivity arrays with Dipole-dipole and Wenner-Schlumberger configurations were used. Current injection and potential dipole separations of 5 m and 10 m were applied across the spring. Inversion results for arrays with the shorter dipole separation of 5 m had better resolution. Resistivity sections were generated from inversion of ERT data. The resistivity values for the low and high resistive zones were ρa < 10 and ρa > 70 Ωm respectively. Sub-horizontal resistivity zones were obtained from the inversion of Wenner-Schlumberger array survey data. High resistivity zones associated with dykes or sills were delineated on Dipole-dipole derived depth sections. Near vertical structures associated with water bearing faults or fractures were delineated at the Siloam hot spring.

Geophysics ◽  
2012 ◽  
Vol 77 (6) ◽  
pp. EN85-EN96 ◽  
Author(s):  
Timothy C. Johnson ◽  
Roelof J. Versteeg ◽  
Mark Rockhold ◽  
Lee D. Slater ◽  
Dimitrios Ntarlagiannis ◽  
...  

Continuing advancements in subsurface electrical resistivity tomography (ERT) are increasing its capabilities for understanding shallow subsurface properties and processes. The inability of ERT imaging data to resolve unique subsurface structures and the corresponding need to include constraining information remains one of the greatest limitations, yet provides one of the greatest opportunities for further advancing the utility of the method. We propose a new method of incorporating constraining information into an ERT imaging algorithm in the form of discontinuous boundaries, known values, and spatial covariance information. We demonstrated the approach by imaging a uranium-contaminated wellfield at the Hanford Site in southeastern Washington State, USA. We incorporate into the algorithm known boundary information and spatial covariance structures derived from the highly resolved near-borehole regions of a regularized ERT inversion. The resulting inversion provides a solution which fits the ERT data (given the estimated noise level), honors the spatial covariance structure throughout the model, and is consistent with known bulk-conductivity discontinuities. The results are validated with core-scale measurements, indicating a significant improvement in accuracy over the standard regularized inversion and revealing important subsurface structure known to influence flow and transport at the site.


Geophysics ◽  
2006 ◽  
Vol 71 (6) ◽  
pp. B231-B239 ◽  
Author(s):  
Jonathan E. Chambers ◽  
Oliver Kuras ◽  
Philip I. Meldrum ◽  
Richard D. Ogilvy ◽  
Jonathan Hollands

A former dolerite quarry and landfill site was investigated using 2D and 3D electrical resistivity tomography (ERT), with the aims of determining buried quarry geometry, mapping bedrock contamination arising from the landfill, and characterizing site geology. Resistivity data were collected from a network of intersecting survey lines using a Wenner-based array configuration. Inversion of the data was carried out using 2D and 3D regularized least-squares optimization methods with robust (L1-norm) model constraints. For this site, where high resistivity contrasts were present, robust model constraints produced a more accurate recovery of subsurface structures when compared to the use of smooth (L2-norm) constraints. Integrated 3D spatial analysis of the ERT and conventional site investigation data proved in this case a highly effective means of characterizing the landfill and its environs. The 3D resistivity model was successfully used to confirm the position of the landfill boundaries, which appeared as electrically well-defined features that corresponded extremely closely to both historic maps and intrusive site investigation data. A potential zone of leachate migration from the landfill was identified from the electrical models; the location of this zone was consistent with the predicted direction of groundwater flow across the site. Unquarried areas of a dolerite sill were imaged as a resistive sheet-like feature, while the fault zone appeared in the 2D resistivity model as a dipping structure defined by contrasting bedrock resistivities.


2020 ◽  
Author(s):  
Laurent Gourdol ◽  
Rémi Clément ◽  
Jérôme Juilleret ◽  
Laurent Pfister ◽  
Christophe Hissler

Abstract. Within the Critical Zone, regolith plays a key role in the fundamental hydrological functions of water collection, storage, mixing and release. Electrical Resistivity Tomography (ERT) is recognized as a remarkable tool for characterizing the geometry and properties of the regolith, overcoming limitations inherent to conventional borehole-based investigations. For exploring shallow layers, a small electrode spacing (ES) will provide a denser set of apparent resistivity measurements of the subsurface. As this option is cumbersome and time-consuming, smaller ES – albeit offering poorer shallow apparent resistivity data – are often preferred for large horizontal ERT surveys. To investigate the negative trade-off between larger ES and reduced accuracy of the inverted ERT images for shallow layers, we use a set of synthetic conductive/resistive/conductive three-layered soil–saprock/saprolite–bedrock models in combination with a reference field dataset. Our results suggest that an increase in ES causes a deterioration of the accuracy of the inverted ERT images in terms of both resistivity distribution and interface delineation and, most importantly, that this degradation increases sharply when the ES exceeds the thickness of the top subsurface layer. This finding, which is obvious for the characterization of shallow layers, is also relevant even when solely aiming for the characterization of deeper layers. We show that an oversized ES leads to overestimations of depth to bedrock and that this overestimation is even more important for subsurface structures with high resistivity contrast. To overcome this limitation, we propose adding interpolated levels of surficial apparent resistivity relying on a limited number of ERT profiles with a smaller ES. We demonstrate that our protocol significantly improves the accuracy of ERT profiles when using large ES, provided that the top layer has a rather constant thickness and resistivity. For the specific case of large-scale ERT surveys the proposed upgrading procedure is cost-effective in comparison to protocols based on small ES.


2022 ◽  
Vol 9 (1) ◽  
Author(s):  
Yonatan Garkebo Doyoro ◽  
Ping-Yu Chang ◽  
Jordi Mahardika Puntu ◽  
Ding-Jiun Lin ◽  
Tran Van Huu ◽  
...  

AbstractGeophysical modelling performs to obtain subsurface structures in agreement with measured data. Freeware algorithms for geoelectrical data inversion have not been widely used in geophysical communities; however, different open-source modelling/inversion algorithms were developed in recent years. In this study, we review the structures and applications of openly Python-based inversion packages, such as pyGIMLi (Python Library for Inversion and Modelling in Geophysics), BERT (Boundless Electrical Resistivity Tomography), ResIPy (Resistivity and Induced Polarization with Python), pyres (Python wrapper for electrical resistivity modelling), and SimPEG (Simulation and Parameter Estimation in Geophysics). In addition, we examine the recovering ability of pyGIMLi, BERT, ResIPy, and SimPEG freeware through inversion of the same synthetic model forward responses. A versatile pyGIMLi freeware is highly suitable for various geophysical data inversion. The SimPEG framework is developed to allow the user to explore, experiment with, and iterate over multiple approaches to the inverse problem. In contrast, BERT, pyres, and ResIPy are exclusively designed for geoelectric data inversion. BERT and pyGIMLi codes can be easily modified for the intended applications. Both pyres and ResIPy use the same mesh designs and inversion algorithms, but pyres uses scripting language, while ResIPy uses a graphical user interface (GUI) that removes the need for text inputs. Our numerical modelling shows that all the tested inversion freeware could be effective for relatively larger targets. pyGIMLi and BERT could also obtain reasonable model resolutions and anomaly accuracies for small-sized subsurface structures. Based on the heterogeneous layered model and experimental target scenario results, the geoelectrical data inversion could be more effective in pyGIMLi, BERT, and SimPEG freeware packages. Moreover, this study can provide insight into implementing suitable inversion freeware for reproducible geophysical research, mainly for geoelectrical modelling.


2021 ◽  
Vol 11 (10) ◽  
pp. 4455
Author(s):  
Alfonso Gutiérrez-Martín ◽  
José I. Yenes ◽  
Marta Fernández-Hernández ◽  
Ricardo Castedo

The paper proposes a novel methodology for the stabilization of shallow foundations, with a simplified model combined with 3D electrical resistivity tomography (ERT-3D and consolidation injections. To determine its usefulness, the method has been applied in a case located in Estepona (southern Spain). The chosen tomography model is the dipole–dipole configuration, with an optimized distance between electrodes of 0.80 m for a better visualization of the foundation subsoil; with this parameterization, a total of 72 electrodes were installed in the analyzed case. In this work, the depth of the anomaly in the building’s supporting subsoil was detected ranging from 2.00 m to 3.90 m deep. The study also delineates areas of high resistivity variations (50–1000 Ω m) in the middle and eastern end of the field. These data have been validated and corroborated with a field campaign. The results of the ERT-3D monitoring are presented, once the investment data has been processed with the RES3DINV software, from the beginning to the end of the stabilization intervention. The novelty occurs with the interaction between the tomography and the foundation consolidation injections, until the final stabilization. This is a very useful methodology in case of emergency consolidation, where there is a need to minimize damage to the building. Thus, people using this combined system will be able to practically solve the initial anomalies of the subsoil that caused the damages, in a non-invasive way, considerably lowering the value of the resistivities.


2016 ◽  
Vol 47 (3) ◽  
pp. 1355
Author(s):  
G. Vargemezis ◽  
N. Diamanti ◽  
I. Fikos ◽  
A. Stampolidis ◽  
Th. Makedon ◽  
...  

Ground penetrating radar (GPR) and electrical resistivity tomography (ERT) surveys have been carried out in the city centre of Thessaloniki (N. Greece), for investigating possible locations of buried building foundations. Geophysical survey has been chosen as a non-destructive investigation method since the area is currently used as a car parking and it is covered by asphalt. The geoelectrical sections derived from ERT data in combination with the GPR profiles provided a broad view of the  subsurface.  Regarding  ERT,  high  resistivity  values  can  be  related  to  buried building remains, while lower resistivity values are more related to the surrounding geological materials. GPR surveying can also indicate man-made structures buried in the ground. Even though the two geophysical methods are affected in different ways by the subsurface conditions, the processed underground images from both techniques revealed great similarity. High resistivity anomalies and distinct GPR signals were observed in certain locations of the area under investigation, which are attributed to buried building foundations as well as the geological structure of the area.


OENO One ◽  
2010 ◽  
Vol 44 (2) ◽  
pp. 51
Author(s):  
Pierre Courjault-Radé ◽  
Muriel Llubes ◽  
José Darrozes ◽  
Marguerite Munoz ◽  
Eric Maire ◽  
...  

<p style="text-align: justify;"><strong>Aims</strong>: The aim of this 2D electrical resistivity tomography (ERT) survey performed on a vineyard plot of the Gaillac appellation was to investigate spatial and temporal variations in subsurface water supply in relation with pedo-geological and morphological features.</p><p style="text-align: justify;"><strong>Methods and results</strong>: The ERT surveys were carried out under two contrasted - dry and humid - climatic conditions. All the resistivity profiles showed the superposition of two layers: a lower layer characterized by very low resistivity values (&lt; 40 <strong>Ω</strong>.m) corresponding to a marly molassic subsoil overlaid by an upper layer characterized by moderate to high resistivity values (300 <strong>Ω</strong>.m to 1500 <strong>Ω</strong>.m) corresponding to a silty-sandy and gravely-pebbly soil sequence. The resistivity values of the molassic subsoil stayed very low independently of water supply conditions whereas those of the soil sequence decreased by a factor 2 (300/750 <strong>Ω</strong>.m versus 750/1500 <strong>Ω</strong>.m) when the plot was close to field capacity.</p><p style="text-align: justify;"><strong>Conclusion</strong>: The ERT results coupled with pedological and morphological data strongly suggest that the water flow is preferentially restricted at the molassic subsoil/soil sequence interface, short-lived and of low amplitude.</p><p style="text-align: justify;"><strong>Significance and impact of the study</strong>: Consequently, the water supply regime, which points out a potential risk of drought stress for vine crops, implies a minimization strategy when choosing vegetal material and viticultural management operations</p>


2014 ◽  
Vol 661 ◽  
pp. 73-80 ◽  
Author(s):  
Andy Anderson Bery ◽  
Rosli Saad

This paper presents 4-D high resolution electrical resistivity tomography study for slope monitoring using two optimized (modified) arrays of the Wenner-Schlumberger and Pole-Dipole. These optimized resistivity arrays give a total of 2052 number of datum points from each data acquisition set. These two optimized were used because they have more datum points compared to their original arrays. Perhaps these optimized arrays were able to resolve the subsurface structures from surface areas. Inversion results from the computer (mathematical models) suggested that these optimized arrays were able to give in imaging the Earth’s subsurface structures and characterization at different period of time. Furthermore, in this paper, we are presented merging data levels in order to give high resolution in electrical resistivity tomography. Even though the time taken for data acquisition using this technique is twice, the outcome is compromised and reliable which helpful in the Earth’s subsurface interpretation.


Geosciences ◽  
2020 ◽  
Vol 10 (4) ◽  
pp. 137
Author(s):  
Maja Briški ◽  
Andrej Stroj ◽  
Ivan Kosović ◽  
Staša Borović

Crystalline rocks are generally characterized by negligible porosity and permeability in terms of groundwater exploitability. However, alteration processes can greatly increase their fracture permeability and induce formation of modest, but locally important aquifers. Therefore, subsurface characteristics of alteration zones are of major importance for hydrogeological evaluation of crystalline terrains. Alteration processes greatly affect rock total porosity and water content, causing contrasting electrical resistivity of rocks affected by varying degrees of weathering. This makes electrical resistivity tomography (ERT) a preferable geophysical method for the exploration of alteration zones in crystalline rocks. In our research, we used an integrated approach, combining the ERT method with monitoring of spring discharge and hydrochemistry to characterize metamorphic aquifers on slopes of the Medvednica Mountain (Croatia). Significant fracture flow aquifers are found to be formed in intensely fractured but not highly weathered rock masses (medium to high resistivity values), while highly weathered masses (low resistivity values) form local barriers for fracture flows. Subsurface structure of the alteration zone proved to be highly irregular, with sharp contacts between more and less weathered rocks. Decrease of permeability below the alteration zone keeps the water level near the surface and enables spring occurrence on the mountain slopes. Studied aquifers have relatively limited extent, resulting in typical capacity of major springs of a few l/s. More frequent but less productive springs are attributed to the draining of the shallow part of the alteration zone (mostly saprolite). Combination of the ERT method with spring monitoring proved to be very effective as a first and relatively inexpensive methodology for hydrogeological characterization of crystalline terrains, both in local and catchment scales.


Sign in / Sign up

Export Citation Format

Share Document