scholarly journals A Validated High-Performance Thin-Layer Chromatographic Method for the Simultaneous Determination of Zofenopril Calcium and Hydrochlorothiazide in the Presence of the Hydrochlorothiazide Impurities: Chlorothiazide and Salamide

2018 ◽  
Vol 101 (4) ◽  
pp. 1031-1041 ◽  
Author(s):  
Mamdouh R Rezk ◽  
Ahmed S Fayed ◽  
Hoda M Marzouk ◽  
Samah S Abbas

Abstract The chromatographic analysis of either process-related impurities or degradation products is very important in the pharmaceutical industry. In this work, a simple, selective, and sensitive HPTLC method was developed and validated for the simultaneous determination of zofenopril calcium (ZOF) and hydrochlorothiazide (HCT) in the presence of the HCT impurities: A) chlorothiazide (CT) and B) salamide, in raw materials and in pharmaceutical formulation. The separation was carried out on HPTLC silica gel 60 F254 using ethyl acetate–glacial acetic acid–triethylamine (10 + 0.1 + 0.1, v/v/v) as a developing system. The separated bands were scanned densitometrically at 270 nm. Polynomial equations were used for the regression. Calibration curves were constructed for ZOF, HCT, CT, and salamide in the ranges of 0.5–10, 0.2–4, 0.05–1.4, and 0.05–1.0 μg/band, respectively. Different parameters affecting the suggested method, including developing systems of varying composition/ratios and different detection wavelengths, were studied to achieve the best resolution and precision with good sensitivity. System suitability parameters were also tested. The proposed method was validated as per the International Conference on Harmonization guidelines and was successfully applied for the quantification of the studied drugs in their pharmaceutical formulation, with no interference from excipients observed. The results obtained by the developed HPTLC method were compared statistically with those obtained by the reported HPLC method using Student’s t and F ratio tests, and no significant difference was obtained, indicating the ability of the proposed method to be used for routine analysis of drug product.

2020 ◽  
Vol 58 (8) ◽  
pp. 747-758
Author(s):  
Said A Hassan ◽  
Nancy W Nashat ◽  
Mohamed R Elghobashy ◽  
Samah S Abbas ◽  
Azza A Moustafa

Abstract Two fast, accurate and selective stability-indicating methods were developed and validated for the simultaneous determination of bisoprolol, perindopril and three of their possible degradation products. The first proposed method was a gradient reversed phase-high-performance liquid chromatography (HPLC) method, whereas the second was a capillary electrophoresis method. The structures of the obtained degradation products were elucidated using infrared and mass spectrometry. They were also confirmed to be either a drug impurity in the British Pharmacopoeia or a precursor to such impurity. The linearity for bisoprolol and perindopril was achieved in the range of 1–20 μg mL−1 and 5–30 μg mL−1 for HPLC and capillary electrophoresis methods, respectively. The proposed methods were validated according to the International Conference on Harmonisation guidelines. The HPLC method proved to be more sensitive and succeeded in the quantitative determination of the obtained degradation products. Also, it was able to quantify perindopril impurity up to three times lower than the desired limit set by the British Pharmacopoeia. They were successfully employed in the determination of bisoprolol and perindopril in their combined pharmaceutical formulation.


2016 ◽  
Vol 99 (6) ◽  
pp. 1490-1498 ◽  
Author(s):  
Amal B Ahmed ◽  
Maha M Abdelrahman ◽  
Nada S Abdelwahab ◽  
Fathy M Salama

Abstract Newly established TLC-densitometric and RP-HPLC methods were developed and validated for the simultaneous determination of Piracetam (PIR) and Vincamine (VINC) in their pharmaceutical formulation and in the presence of PIR and VINC degradation products, PD and VD, respectively. The proposed TLC-densitometric method is based on the separation and quantitation of the studied components using a developing system that consists of chloroform–methanol–glacial acetic acid–triethylamine (8 + 2 + 0.1 + 0.1, v/v/v/v) on TLC silica gel 60 F254 plates, followed by densitometric scanning at 230 nm. On the other hand, the developed RP-HPLC method is based on the separation of the studied components using an isocratic elution of 0.05 M KH2PO4 (containing 0.1% triethylamine adjusted to pH 3 with orthophosphoric acid)–methanol (95 + 5, v/v) on a C8 column at a flow rate of 1 mL/min with diode-array detection at 230 nm. The developed methods were validated according to International Conference on Harmonization guidelines and demonstrated good accuracy and precision. Moreover, the developed TLC-densitometric and RP-HPLC methods are suitable as stability-indicating assay methods for the simultaneous determination of PD and VD either in bulk powder or pharmaceutical formulation. The results were statistically compared with those obtained by the reported RP-HPLC method using t- and F-tests.


2020 ◽  
Vol 32 (2) ◽  
pp. 122-127
Author(s):  
Amir Ali ◽  
Umar Farooq ◽  
Mahmood Ahmed ◽  
Muhammad Makshoof Athar ◽  
M. Salman ◽  
...  

The present work described a simple, rapid, sensitive, accurate, and precise method for simultaneous determination of chlorpheniramine maleate (CHRM) and prednisolone acetate (PRED) in injection samples by high-performance liquid chromatography (HPLC) coupled with UV–Vis detection. Chromatographic separation was accomplished, employing isocratic mode and a mobile phase comprised of acetonitrile and a phosphate buffer (50:50, v/v, 30 °C), adjusted to pH 3.0. The flow rate used was 1.0 mL/min on a Thermo Hypersil ODS C18 column (5 μm, 4.6 × 250 mm), and the injection volume of sample was 20 μL. Analysis of CHRM and PRED was performed at a wavelength of 254 nm. The runtime for analysis was 12.5 min, and the retention times of CHRM and PRED were found to be 2.81 and 5.07 min, respectively. The calibration graph showed linearity over the concentration range 10–70 μg/mL for CHRM and 20–140 μg/mL for PRED with a coefficient of determination (R2) ≥0.9986. Repeatability and reproducibility (expressed as % RSD) were lower than 1.72 and 1.47%, respectively. The proposed HPLC method was demonstrated to be simple and rapid for the determination of CHRM and PRED in injection formulation, providing recoveries between 101.6–102.3%, whereas complete separation of degradation products, from analyte under investigation, provided the specificity of the proposed HPLC method.


2006 ◽  
Vol 89 (6) ◽  
pp. 1552-1556
Author(s):  
ArmaĞan Önal ◽  
Olcay SaĞiri ◽  
S Müge Çetin ◽  
Sidika Toker

Abstract Reboxetine is used as a selective noradrenaline reuptake inhibitor for the treatment of major depressive disorders. It is effective in the treatment of severe depression and safer to use than traditional tricyclic antidepressants. In this study, a novel, simple, and rapid stability-indicating high-performance liquid chromatography (HPLC) method for reboxetine methansulfonate was successfully developed and validated for the assay of tablets. The method was used to quantify reboxetine in tablets; it employed a C18 column (150 4.6 mm id) with an isocratic mobile phase consisting of methanolphosphate buffer (pH 7, 0.02 M; 55 + 45, v/v) at a flow rate of 1.0 μmL/min. Reboxetine was detected by an ultraviolet detector at 277 nm. The retention time of reboxetine was about 4.5 min. The developed HPLC method was validated with respect to linearity, precision, sensitivity, accuracy, and selectivity. The method was linear over the concentration range 150 g/mL (r 0.9999). The limits of detection and the quantitation of reboxetine were 0.1 and 0.3 μg/mL, respectively. The relative standard deviation values for intraday and interday precision were 0.781.01 and 1.081.37%, respectively. Selectivity was validated by subjecting a stock solution of reboxetine to neutral, acid, and alkali hydrolysis, as well as oxidation, dry heat treatment, and photodegradation. The peaks of the degradation products did not interfere with the peak of reboxetine. The results indicated that the proposed method could be used in a stability assay. The proposed method was successfully applied to the determination of reboxetine in tablets. Excipients present in the tablets did not interfere with the analysis.


2011 ◽  
Vol 8 (1) ◽  
pp. 340-346 ◽  
Author(s):  
Rajesh M. Kashid ◽  
Santosh G. Singh ◽  
Shrawan Singh

A reversed phase HPLC method that allows the separation and simultaneous determination of the preservatives methyl paraben (M.P.) and propyl paraben (P.P.) is described. The separations were effected by using an initial mobile phase of water: acetonitrile (50:50) on Inertsil C18 to elute P.P. and M.P. The detector wavelength was set at 205 nm. Under these conditions, separation of the two components was achieved in less than 10 min. Analytical characteristics of the separation such as precision, specificity, linear range and reproducibility were evaluated. The developed method was applied for the determination of preservative M.P. and P.P. at concentration of 0.01 mg/mL and 0.1 mg/mL respectively. The method was successfully used for determining both compounds in sucralfate suspension.


2016 ◽  
Vol 8 (30) ◽  
pp. 5949-5956 ◽  
Author(s):  
Soumia Boulahlib ◽  
Ali Boudina ◽  
Kahina Si-Ahmed ◽  
Yassine Bessekhouad ◽  
Mohamed Trari

In this study, a rapid and simple method based on reversed-phase high performance liquid chromatography (RP-HPLC) using a photodiode array detector (PDA) for the simultaneous analysis of five pollutants including aniline and its degradation products, para-aminophenol, meta-aminophenol, ortho-aminophenol and phenol, was developed.


Author(s):  
V.L.N. Balaji Gupta Tiruveedhi ◽  
Venkateswara Rao Battula ◽  
Kishore Babu Bonige ◽  
Tejeswarudu B.

This research work was designed to establish and validate a novel stability indicating RP-HPLC method for the combined determination of Benidipine hydrochloride (BHE) and Nebivolol hydrochloride (NHE) in bulk and tablets, dependent on ICH guidelines.The assay method to analyse BHE and NHE was optimized with isocratic elution using acetonitrile: 0.1M acetate buffer (45:55, pH 5.1), Lichrospher ODS RP-18 column and flow pace of 1 ml/min. Total time for single run was 14 min. The injection quantity was 20μl, and was detected at 249nm. The method was verified on a concentration series of 1.25-10μg/ml (NHE) and 1.0-10μg/ml (BHE) for precision, accuracy and linearity. The LOD values were 0.059µg/ml and 0.028µg/ml for NHE and BHE, respectively. The LOQ values were 0.196µg/ml for NHE and 0.094µg/ml for BHE. The recovery percentages were 98.60-100.11% (BHE) and 98.94-101.50% (NHE) with relative standard deviation 0.250-0.694% (BHE) and 0.183-0.400% (NHE). The method was also observed to be efficient, and was sufficiently specific to measure BHE and NHE in the presence of stress-produced degradation products.


2016 ◽  
Vol 9 (1) ◽  
pp. 54
Author(s):  
Megha Sharma ◽  
Neeraj Mahindroo

Objective: The objective of the present study was to develop and validate a novel stability indicating reverse phase-high performance liquid chromatography (RP-HPLC) method for determination of β-acetyldigoxin, an active pharmaceutical ingredient (API).Methods: The chromatographic separation was carried out on Agilent Technologies 1200 series HPLC system equipped with photo diode array detector and C-18 (4.6x250 mm, 5 µ) column. The mobile phase consisted of water: acetonitrile (65:35 v/v), delivered at a flow rate of 1.5 ml/min and eluents were monitored at 225 nm.Results: The retention time of β-acetyldigoxin was 9.2 min. The method was found to be linear (R2= 0.9995) in the range of 31.25-500 µg/ml. The accuracy studies showed the mean percent recovery of 101.02%. LOD and LOQ were observed to be 0.289 µg/ml and 0.965 µg/ml, respectively. The method was found to be robust and system suitability testing was also performed. Forced degradation analysis was carried out under acidic, alkaline, oxidative and photolytic stress conditions. Significant degradation was observed under tested conditions, except for oxidative condition. The method was able to separate all the degradation products within runtime of 20 min and was able to determine β-acetyldigoxin unequivocally in presence of degradation products.Conclusion: The novel, economic, rapid and simple method for analysis of β-acetyldigoxin is reported. The developed method is suitable for routine quality control and its determination as API, and in pharmaceutical formulations and stability study samples.


2020 ◽  
Vol 58 (5) ◽  
pp. 411-417
Author(s):  
Maimana A Magdy ◽  
Rehab M Abdelfatah

Abstract A binary mixture of Silymarin (SR) and Vitamin E (VE) acetate, of an antioxidant and a hepatoprotective effect, has been analyzed using a sensitive, selective and economic high performance thin layer chromatographic (HPTLC) method in their pure forms, pharmaceutical formulation and spiked human plasma. SR and VE were separated on 60F254 silica gel plates using hexane:acetone:formic acid (7:3:0.15, v/v/v) as a developing system with UV detection at 215 nm. The method was evaluated for linearity, accuracy, precision, selectivity, limit of detection (LOD) and limit of quantification (LOQ). SR and VE were detected in the linear range of 0.2–2.5 and 0.2–4.5 μg/band, respectively. Method validation was done as per ICH guidelines and acceptable results of accuracy of 99.86 ± 1.190 and 100.22 ± 1.609 for SR and VE, respectively were obtained. The method has been successfully applied for determination of the studied drugs in their pharmaceutical formulation without any interference from excipients, and in spiked plasma samples. Results obtained by the developed HPTLC-densitometric method were statistically compared to those obtained by the reported HPLC methods and no significant difference was found between them.


Sign in / Sign up

Export Citation Format

Share Document