A Validated Routine Method for Butyltin Determination in Seafood by Gas Chromatography Inductively Coupled Plasma Isotope Dilution Mass Spectrometry

2019 ◽  
Vol 102 (1) ◽  
pp. 278-285
Author(s):  
Stig Valdersnes ◽  
Berit Solli ◽  
Veronika Sele ◽  
Kåre Julshamn

Abstract Organotin compounds are anthropogenic metal species with multiple uses as pesticides, preservatives, antifouling agents, biocides, and catalysts. Butyltins are the main organotin compounds found in biota, and the highest levels are found in marine foodstuffs. In this paper, we present the figures of merit for an in-house validated method for routine analysis of butyltins in seafood using GC inductively coupled plasma isotope dilution MS. The working range of the method spanned several orders of magnitude from 3.3–1013, 2.4–785, and 0.3–900 ng Sn/g dry weight for monobutyltin (MBT), dibutyltin (DBT), and tributyltin (TBT), respectively. The trueness of the method was evaluated by analyzing Certified Reference Materials (CRMs) ERM CRM 477 (Mussel Tissue) and NIES CRM 15 (Scallop). Recoveries, with RSD % in parentheses, were 78 (±14), 80 (±6), and 88% (±8%) for MBT, DBT, and TBT in ERM CRM 477 and 96% (±5%) for TBT in NIES CRM 15. Good agreements were found between experimental uncertainties and uncertainties predicted for single-laboratory validated methods calculated from the maximum standard measurement uncertainty function. The method has proven to be robust, and the wide range of seafood validated ensures that the method is applicable for measuring butyltins in marine tissue.

Molecules ◽  
2021 ◽  
Vol 26 (9) ◽  
pp. 2649
Author(s):  
Christine Brauckmann ◽  
Axel Pramann ◽  
Olaf Rienitz ◽  
Alexander Schulze ◽  
Pranee Phukphatthanachai ◽  
...  

A new method combining isotope dilution mass spectrometry (IDMS) and standard addition has been developed to determine the mass fractions w of different elements in complex matrices: (a) silicon in aqueous tetramethylammonium hydroxide (TMAH), (b) sulfur in biodiesel fuel, and (c) iron bound to transferrin in human serum. All measurements were carried out using inductively coupled plasma mass spectrometry (ICP–MS). The method requires the gravimetric preparation of several blends (bi)—each consisting of roughly the same masses (mx,i) of the sample solution (x) and my,i of a spike solution (y) plus different masses (mz,i) of a reference solution (z). Only these masses and the isotope ratios (Rb,i) in the blends and reference and spike solutions have to be measured. The derivation of the underlying equations based on linear regression is presented and compared to a related concept reported by Pagliano and Meija. The uncertainties achievable, e.g., in the case of the Si blank in extremely pure TMAH of urel (w(Si)) = 90% (linear regression method, this work) and urel (w(Si)) = 150% (the method reported by Pagliano and Meija) seem to suggest better applicability of the new method in practical use due to the higher robustness of regression analysis.


Sign in / Sign up

Export Citation Format

Share Document