scholarly journals Orthopaedic Biomechanics: A Practical Approach to Combining Mechanical Testing and Finite Element Analysis

Author(s):  
Rad Zdero ◽  
Habiba Bougherar
1999 ◽  
Author(s):  
Michael D. Nowak ◽  
Kim Haser ◽  
A. Jon Goldberg

Abstract Work is continuing in the evaluation of orthotropic fiber reinforce composites for use in the construction of dental bridges. Finite Element Analysis (FEA) models were constructed based upon mechanical testing of end clamped specimens center loaded with a metal indenter. Various length / depth specimens were evaluated in the elastic range, with a variety of load magnitudes. Separate FEA models utilized single point loading, distributed loading, and the construction of a model indenter. Deflections at the loading point demonstrated that all models presented similar findings to those seen in mechanical testing. The similarity of results between the single loading point and the indenter FEA models suggest that either is reasonable for elastic range testing. The significantly shorter CPU run times for the single force models suggest that this may be the best means by which to model orthotropic fiber reinforced dental composites in the elastic range.


Materials ◽  
2019 ◽  
Vol 12 (20) ◽  
pp. 3444
Author(s):  
Avram Manea ◽  
Grigore Baciut ◽  
Mihaela Baciut ◽  
Dumitru Pop ◽  
Dan Sorin Comsa ◽  
...  

Background: Once inserted and osseointegrated, dental implants become ankylosed, which makes them immobile with respect to the alveolar bone. The present paper describes the development of a new and original implant design which replicates the 3D physiological mobility of natural teeth. The first phase of the test followed the resistance of the implant to mechanical stress as well as the behavior of the surrounding bone. Modifications to the design were made after the first set of results. In the second stage, mechanical tests in conjunction with finite element analysis were performed to test the improved implant design. Methods: In order to test the new concept, 6 titanium alloy (Ti6Al4V) implants were produced (milling). The implants were fitted into the dynamic testing device. The initial mobility was measured for each implant as well as their mobility after several test cycles. In the second stage, 10 implants with the modified design were produced. The testing protocol included mechanical testing and finite element analysis. Results: The initial testing protocol was applied almost entirely successfully. Premature fracturing of some implants and fitting blocks occurred and the testing protocol was readjusted. The issues in the initial test helped design the final testing protocol and the new implants with improved mechanical performance. Conclusion: The new prototype proved the efficiency of the concept. The initial tests pointed out the need for design improvement and the following tests validated the concept.


2010 ◽  
Vol 28 (6) ◽  
pp. E11 ◽  
Author(s):  
Neil R. Crawford ◽  
Jeffery D. Arnett ◽  
Joshua A. Butters ◽  
Lisa A. Ferrara ◽  
Nikhil Kulkarni ◽  
...  

Different methods have been described by numerous investigators for experimentally assessing the kinematics of cervical artificial discs. However, in addition to understanding how artificial discs affect range of motion, it is also clinically relevant to understand how artificial discs affect segmental posture. The purpose of this paper is to describe novel considerations and methods for experimentally assessing cervical spine postural control in the laboratory. These methods, which include mechanical testing, cadaveric testing, and computer modeling studies, are applied in comparing postural biomechanics of a novel postural control arthroplasty (PCA) device versus standard ball-and-socket (BS) and ball-in-trough (BT) arthroplasty devices. The overall body of evidence from this group of tests supports the conclusion that the PCA device does control posture to a particular lordotic position, whereas BS and BT devices move freely through their ranges of motion.


2014 ◽  
Vol 15 (11) ◽  
pp. 2335-2342 ◽  
Author(s):  
Hyock-Ju Kwon ◽  
Jiwon Lee ◽  
Bonghun Shin ◽  
Soo Jeon ◽  
Chung Su Han ◽  
...  

Author(s):  
Steven Higbee ◽  
Sharon Miller

Abstract Insufficient engineering analysis is a common weakness of student capstone design projects. Efforts made earlier in a curriculum to introduce analysis techniques should improve student confidence in applying these important skills toward design. To address student shortcomings in design, we implemented a new design project assignment for second-year undergraduate biomedical engineering students. The project involves the iterative design of a fracture fixation plate and is part of a broader effort to integrate relevant hands-on projects throughout our curriculum. Students are tasked with (1) using computer-aided design (CAD) software to make design changes to a fixation plate, (2) creating and executing finite element models to assess performance after each change, (3) iterating through three design changes, and (4) performing mechanical testing of the final device to verify model results. Quantitative and qualitative methods were used to assess student knowledge, confidence, and achievement in design. Students exhibited design knowledge gains and cognizance of prior coursework knowledge integration into their designs. Further, students self-reported confidence gains in approaching design, working with hardware and software, and communicating results. Finally, student self-assessments exceeded instructor assessment of student design reports, indicating that students have significant room for growth as they progress through the curriculum. Beyond the gains observed in design knowledge, confidence, and achievement, the fracture fixation project described here builds student experience with CAD, finite element analysis, 3D printing, mechanical testing, and design communication. These skills contribute to the growing toolbox that students ultimately bring to capstone design.


2008 ◽  
Vol 133 (2) ◽  
pp. 188.e9-188.e13 ◽  
Author(s):  
Maria Elisa Rodrigues Coimbra ◽  
Norman Duque Penedo ◽  
Jayme Pereira de Gouvêa ◽  
Carlos Nelson Elias ◽  
Mônica Tirre de Souza Araújo ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document