scholarly journals Artificial Intelligence in Light-Source Design

Author(s):  
Snjezana Soltic ◽  
Andrew N. Chalmers
2019 ◽  
Author(s):  
Yueping Zheng ◽  
Ruizhang Su ◽  
Wangyue Wang ◽  
Sijun Meng ◽  
Hang Xiao ◽  
...  

ABSTRACTObjectiveArtificial intelligence (AI) has undeniable values in detection, characterization, and monitoring of tumors during cancer imaging. However, major AI explorations in digestive endoscopy have not been systematically planned, and more important, most AI productions are based on Single-center Studies (ScSs). ScSs result in data scarcity, redundancy as well as island effects, which leads to some limitations in applying it on endoscopy. We investigate the disadvantages of picture processing which may effect the AI detection, and make improvements in AI detection and image recognition accuracy.DesignCurrent investigation aggregates a total of 2,500 gastroenteroscopy samples from various hospitals in multiple regions and carries out deep learning.ResultsIt is found that factors inconducive to AI recognition are common such as: (a) the gastrointestinal tract is not cleaned up completely; (b) shooting angle (from left to right and the top of polyp are unexposed clearly), shooting distance (too close or too far to shoot causes the lump to be unclear), shooting light (insufficient light source or overexposed light source in mass) and unstable shooting lead to poor quality of pictures.ConclusionWe set standards for a multicenter cooperation involving three-level medical institutions from the provincial, municipal and county to improve the recognition accuracy as well as the diagnosis and treatment efficiency meanwhile.


Author(s):  
Yu- Hui Ma ◽  
Lin- Feng Li ◽  
Yu- Xuan Zhang ◽  
Yu Zhang ◽  
Yu- Ting Wang ◽  
...  

On the basis of a large number of previous studies, we develop the TCM Tongue diagnosis mobile phone software based on artificial intelligence technology which is named Tongue Diagnosis Cabin. The software utilizes and improves the digital objectification technology of modern tongue image to overcome the influence of the pixel limitation of the mobile phone, the complex shooting environment, the unstable light source and other conditions on the color and definition of the original tongue image, and reduces the total difference between the remote tongue image and the original tongue image color, so as to achieve clinical visual equivalence. The software is based on the mobile phone, which is easy to operate with intelligently guidance and superior performance, and can promote the development of digitalization and telemedicine of tongue diagnosis. Keywords: tongue diagnosis cabin; tongue diagnosis; intelligence; mobile; telemedicine


Author(s):  
Michael T. Bucek ◽  
Howard J. Arnott

It is believed by the authors, with supporting experimental evidence, that as little as 0.5°, or less, knife clearance angle may be a critical factor in obtaining optimum quality ultrathin sections. The degree increments located on the knife holder provides the investigator with only a crude approximation of the angle at which the holder is set. With the increments displayed on the holder one cannot set the clearance angle precisely and reproducibly. The ability to routinely set this angle precisely and without difficulty would obviously be of great assistance to the operator. A device has been contrived to aid the investigator in precisely setting the clearance angle. This device is relatively simple and is easily constructed. It consists of a light source and an optically flat, front surfaced mirror with a minute black spot in the center. The mirror is affixed to the knife by placing it permanently on top of the knife holder.


Author(s):  
P.M. Houpt ◽  
A. Draaijer

In confocal microscopy, the object is scanned by the coinciding focal points (confocal) of a point light source and a point detector both focused on a certain plane in the object. Only light coming from the focal point is detected and, even more important, out-of-focus light is rejected.This makes it possible to slice up optically the ‘volume of interest’ in the object by moving it axially while scanning the focused point light source (X-Y) laterally. The successive confocal sections can be stored in a computer and used to reconstruct the object in a 3D image display.The instrument described is able to scan the object laterally with an Ar ion laser (488 nm) at video rates. The image of one confocal section of an object can be displayed within 40 milliseconds (1000 х 1000 pixels). The time to record the total information within the ‘volume of interest’ normally depends on the number of slices needed to cover it, but rarely exceeds a few seconds.


Author(s):  
David L. Poole ◽  
Alan K. Mackworth

2018 ◽  
Vol 32 (4) ◽  
pp. 182-190 ◽  
Author(s):  
Kenta Matsumura ◽  
Koichi Shimizu ◽  
Peter Rolfe ◽  
Masanori Kakimoto ◽  
Takehiro Yamakoshi

Abstract. Pulse volume (PV) and its related measures, such as modified normalized pulse volume (mNPV), direct-current component (DC), and pulse rate (PR), derived from the finger-photoplethysmogram (FPPG), are useful psychophysiological measures. Although considerable uncertainties exist in finger-photoplethysmography, little is known about the extent of the adverse effects on the measures. In this study, we therefore examined the inter-method reliability of each index across sensor positions and light intensities, which are major disturbance factors of FPPG. From the tips of the index fingers of 12 participants in a resting state, three simultaneous FPPGs having overlapping optical paths were recorded, with their light intensity being changed in three steps. The analysis revealed that the minimum values of three coefficients of Cronbach’s α for ln PV, ln mNPV, ln DC, and PR across positions were .948, .850, .922, and 1.000, respectively, and that those across intensities were .774, .985, .485, and .998, respectively. These findings suggest that ln mNPV and PR can be used for psychophysiological studies irrespective of minor differences in sensor attachment positions and light source intensity, whereas and ln DC can also be used for such studies but under the condition of light intensity being fixed.


Sign in / Sign up

Export Citation Format

Share Document