scholarly journals DIANTIPYRYLPROPYLMETHANE AS ELECTRODE-ACTIVE COMPONENTS OF MEMBRANE OF LEAD SELECTIVE ELECTRODE

Author(s):  
Sarizhat D. Tataeva ◽  
Arsen Sh. Ramazanov ◽  
Victoriya S. Magomedova ◽  
Kurban E. Magomedov ◽  
Ruslan Z. Zeynalov

The possibility of approbation of an ion-selective electrode based on diantipyrylpropylmethane for determination of lead is considered in the work. Optimization of the membrane composition of an ion-selective electrode was carried out with the change of weight ratios of membrane components. The best results were obtained with the addition of potassium tetraphenylborate by weight of 1.35%. According to the obtained experimental steepness, a membrane of composition (wt.%) was chosen: PVC (32.62), o-PFOE (65.25), DAPPM (1.35), NaTPB (0.78). The linearity interval of the electrode with an optimized composition of the membrane was observed in the concentration range of 10-6 -10-1 M, with a response of 10 s. The slope of the Pb-SE function is 27.4 ± 0.5 mV / pC. The influence of the acidity of the medium on the Pb-SE response was studied. At the pH=3-5 a potential of the Pb-SE for the compositions remains stable with a drift not more than 2 mV. For a given electrode, the selectivity coefficients were determined by the method of bionic potentials with respect to some d-elements, as well as alkaline and alkaline-earth metals. The influence of zinc, cadmium, mercury and copper ions on the membrane response is significant, which requires the use of various masking reagents in potentiometric analysis in the presence of these ions. To increase the selectivity of the membrane to lead ions, 0.1 M NH4SCN was introduced into the solution under analysis to bind Cu (II), Zn (II), Hg (II) and Cd (II) ions to stronger ammonium complexes. The proposed electrode favorably differs by the interval of the determined concentrations (M) - 10-6 - 10-1; high selectivity, and also increases in the stability of the membrane due to high lipophilicity relative to diantipyrylmethane.Forcitation:Tataeva S.D., Ramazanov A.Sh., Magomedova V.S., Magomedov K.E., Zeynalov R.Z. Diantipyrylpropylmethane as electrode-active components of membrane of lead selective electrode. Izv. Vyssh. Uchebn. Zaved. Khim. Khim. Tekhnol. 2018. V. 61. N 2. P. 23-28

Sensors ◽  
2020 ◽  
Vol 20 (10) ◽  
pp. 2817
Author(s):  
Marcin Urbanowicz ◽  
Kamila Sadowska ◽  
Dorota G. Pijanowska ◽  
Radosław Pomećko ◽  
Maria Bocheńska

A new solid-contact potentiometric ion-selective electrode for the determination of SCN− (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included selection of a plasticizer for the ion-selective membrane composition and type of the electrode material. The study was carried out using ISE with liquid internal electrolyte (LE-ISE) and solid-contact electrodes made of glassy carbon (GC-ISE) and gold rods (Au-ISE). The best parameters were found for GC sensors for which the ion-selective membrane contained chloroparaffin as a plasticizer (S = 59.9 mV/dec, LOD = 1.6 × 10−6 M). The study of potentiometric selectivity coefficients has shown that the thiocyanate-selective sensor could be applied in biomedical research for determination of SCN− concentration in human saliva. The accuracy of the SCN− determination was verified by testing 59 samples of volunteers’ saliva by potentiometric sensors and UV-Vis spectrophotometry as a reference technique. Moreover, SCN− concentrations in the smokers’ and non-smokers’ saliva were compared. In order to investigate the influence of various factors (sex, health status, taken medications) on the thiocyanate level in the saliva, more extensive studies on a group of 100 volunteers were carried out. Additionally, for a group of 18 volunteers, individual profiles of SCN− concentration in saliva measured on a daily basis for over a month were collected.


1981 ◽  
Vol 46 (2) ◽  
pp. 368-376 ◽  
Author(s):  
Josef Veselý

Titration of sulphates with lead perchlorate employing lead ion selective electrode indication was studied using additions of various organic solvents at different pH' and ionic strength values. As the optimum emerged systems with 60-70% 1,4-dioxane, pH' 5.3-5.6. After dehydration with sodium hydroxide, dioxane must be freed from the electrode surface-oxidizing impurities by their reduction with sodium metal and subsequent distillation. The method was applied to determination of sulphates in mountain spring waters. Units of ppm can be determined; the limit of determination, however, depends considerably on the content of dioxane, total salt content in the sample, and speed of the semi-automatic titration. Lead can be determined with EDTA in concentrations down to c(Pb2+) = 5 . 10-6 mol l-1.


Chemosensors ◽  
2021 ◽  
Vol 9 (7) ◽  
pp. 155
Author(s):  
Yan Su ◽  
Ting Liu ◽  
Caiqiao Song ◽  
Aiqiao Fan ◽  
Nan Zhu ◽  
...  

As an essential electrolyte for the human body, the potassium ion (K+) plays many physiological roles in living cells, so the rapid and accurate determination of serum K+ is of great significance. In this work, we developed a solid-contact ion-selective electrode (SC-ISE) using MoS2/Fe3O4 composites as the ion-to-electron transducer to determine serum K+. The potential response measurement of MoS2/Fe3O4/K+-ISE shows a Nernst response by a slope of 55.2 ± 0.1 mV/decade and a low detection limit of 6.3 × 10−6 M. The proposed electrode exhibits outstanding resistance to the interference of O2, CO2, light, and water layer formation. Remarkably, it also presents a high performance in potential reproducibility and long-term stability.


1997 ◽  
Vol 349 (1-3) ◽  
pp. 59-65 ◽  
Author(s):  
M. Gerlache ◽  
Z. Sentürk ◽  
J.C. Viré ◽  
J.M. Kauffmann

Sign in / Sign up

Export Citation Format

Share Document