scholarly journals RP-HPLC Method for Quantification of Emtricitabine and Tenofovir Alafenamide Fumarate Drug Substance and Tablet Dosage Form

Author(s):  
P. Sunand Sarat ◽  
D. Ramachandran

Aim: The primary objective of the research work is to develop a effective, sensitive, economical and simple reverse phase HPLC method to estimate Emtricitabine and tenofovir alafenamide fumarate in its pure and binary mixture of tablets. Study Design: HPLC based Quantification Studies. Place and Duration of Study: 1Department of Chemistry, Acharya Nagarjuna University,Guntur, Andhra Pradesh between April 2019 and August 2020. Methodology: Separation of the analytes were done by  using Eclipse XDB-Phenyl (250 x 4.6mm, 5µ,100 A0) column and a mobile phase ratio of 30:10:70 percentage of 0.1% trifluoro acetic acid: acetonitile: methanol  at a  flow rate of 1 ml/min. The injected standard and sample solutions were detected 260nm wavelength. Results: The retention time of Emtricitabine and tenofovir alafenamide fumarate were found at 2.3min and 2.8 min respectively. The method has good linearity range about 50 to 150µg/ml of Emtricitabine  and 6.5 to 19.5 µg/ml of  tenofovir alafenamide fumarate. The method has validated as per ICH guidelines and all the validation parameterwere satisfy the ICH Q2 specification acceptance limits Conclusion: The developed method said to be highly sensitive, accurate, specific and robust, therefore this method has high probability to adopt in pharmaceutical industry for regular analysis of   Emtricitabine  and tenofovir alafenamide.

INDIAN DRUGS ◽  
2013 ◽  
Vol 50 (06) ◽  
pp. 20-23
Author(s):  
S Sahoo ◽  
◽  
P. K. Panda ◽  
S. K. Mishra

A simple, fast, accurate and precise reverse phase HPLC method is developed and described for the determination of ramelteon in tablet dosage form. Chromatography was carried on an ODS column using a mixture of acetonitrile and phosphate buffer pH 7.0 (35:65 V/V) as the mobile phase at a flow rate of 1.0 mL/min with detection at 286 nm. The retention time of the drug was 7.7 min. The procedure was validated for linearity, precision, accuracy, and robustness. The developed method was validated for linearity from 50 to 150% which shows the method is quite linear with a correlation coefficient of 0.999, for precision which includes system precision, method precision, intraday and by another analyst on another day, and accuracy. The %RSD for system precision was observed to be 1.1, whereas the method precision was observed to be 0.2. The % recovery from ‘accuracy’ studies yielded the recovery of 99.7-101.5% which indicates the capability of the method, and finally for robustness that includes studies w.r.t. change in flow rate, the percentage of organic modifier and pH. As per ICH guidelines, method validation results are in good agreement. The proposed method was simple, sensitive, precise and accurate.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (09) ◽  
pp. 43-54
Author(s):  
K Vijaya Sri ◽  
M. Madhuri ◽  
V. Anusha ◽  
V.R.K. Siresha ◽  

The present research work illustrates the development and validation of RP HPLC method for simultaneous estimation of tenofovir disproxil fumarate, emtricitabine and rilpivirine hydrochloride in bulk and formulated in a pharmaceutical dosage form as a nanosupension. Antiretroviral drug treatment is the primary line of therapy for treating HIV. The multicomponent system formulated as a nanosuspension evidenced increased hydrophilicity, potency and decreased side effects. The separation was carried out by using efficient BDS hypersil C18 HPLC column with empower software. Combination method of Precipitation—ultrasonic homogenization was used for the preparation of the nanosuspension. The mobile phase used was methanol, water, acetonitrile (80:13.4:6.6) v/v and flow rate 1mL /min. The developed method was thus validated as per ICH guidelines for various parameters whose results advocated the reliability of the method. The results for parameters viz. retention times of tenofovir disproxil fumarate, emtricitabine and rilpivirine were 3.09 min, 2.78 min and 3.68 min, linearity range was between 7.5-90, 5-60, 0.625-7.5µg/mL, respectively. Thus the new RP-HPLC method is optimum, reliable and can be used for the simultaneous estimation of tenofovir disproxil fumarate, emtricitabine and rilpivirine hydrochloride.


2013 ◽  
Vol 49 (2) ◽  
pp. 359-366 ◽  
Author(s):  
Mustafa Çelebier ◽  
Tuba Reçber ◽  
Engin Koçak ◽  
Sacide Altinöz

Rivaroxaban, an anti-clotting medication, acts at a crucial point in the blood-clotting process and stops the formation of blood clots. In this study, RP-HPLC method was developed for the determination of rivaroxaban in tablets (Xarelto® (10 mg)). Phenomenex Luna 5 µm C18 100 Å LC Column (250 x 4.6 mm) was used at 40 ºC. Isocratic elution was performed with ACN:Water (55:45 v/v) mixture. The flow rate was 1.2 mL min-1 and UV detection was at 249 nm. Internal standard (Caffeine) and rivaroxaban were eluted within 2.21 and 3.37 minutes, respectively. The developed method was validated according to the ICH guidelines and found to be linear within the range 0.005 - 40.0 µg mL-1. The method was accurate, precise, robust and rapid. Thus, it was applied successfully for the quality control assay of rivaroxaban in tablet dosage form.


Author(s):  
Sireesha D ◽  
Sai Lakshmi E ◽  
Sravya E ◽  
Vasudha Bakshi

A new simple, rapid, specific, accurate, precise and novel Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method has been developed for the estimation of Sitagliptin Phosphate in the pharmaceutical dosage form. The chromatographic separation for Sitagliptin was achieved with mobile phase containing methanol, Thermoscientific C18 column, (250x4.6 particle size of 5μ) at room temperature and UV detection at 248 nm. The compounds were eluted in the isocratic mode at a flow rate of 1ml/min. The retention time of Sitagliptin was 1.91min. The above method was validated in terms of linearity, accuracy, precision, LOD and LOQ in accordance with ICH guidelines.


Author(s):  
Devi Ramesh ◽  
Mohammad Habibuddin

Objective: The objective of the present study is to develop and validate a simple, rapid, sensitive reverse phase HPLC method for the determination of Armodafinil present in bulk and its pharmaceutical formulations.Methods: The chromatographic separation was achieved by using Hypersil ODS C-18 (150 x 4.6 mm, 5µ) in an isocratic mode with mobile phase methanol: phosphate buffer 3.0 (60:40 %v/v) was used. The flow rate was 1 ml/min and effluent was monitored at 225 nm. The method was validated for validation parameters i.e. linearity, accuracy, precision and robustness according to ICH guidelines.Results: The retention time of Armodafinil was 4.2 min and the linearity range of the method was 500-20000ng/ml with regression (r2) coefficient 0.9998. The method was validated for precision, accuracy, robustness and which were found to be within the acceptable limits according to the ICH guidelines. Also, the method was successfully applied for the estimation of Armodafinil in the marketed formulation of Nuvigil and the recovery was found to be>98%.Conclusion: The developed method possess good selectivity, specificity, there is no interference found in the blank at a retention time of ARM and good correlation between the peak area and concentration of the drugs under prescribed conditions. Hence, the method can be applied for routine analysis of Armodafinil. 


2019 ◽  
Vol 6 (1) ◽  
Author(s):  
Ananda Thangadurai Subramaniam ◽  
Devi Velmurugan ◽  
Sambathkumar Ramanathan ◽  
Kamalakannan Dhanabalan ◽  
Jambulingam Munusamy ◽  
...  

Recent study was conducted to develop and validate analytical methods for estimation of Risedronate sodium in pure and pharmaceutical dosage form using UV Spectroscopy and               RP- HPLC method. The first method (Method A) based on the UV Spectroscopy using 0.1M Hcl as diluent lambda max was found at 261 nm. Linearity existed perceived in the concentration between 10-50 μg/ml (r 2 = 0.999) for the method. The method was validated pertaining to linearity, precision and accuracy studies, LOD and LOQ consistent with ICH guidelines. The second method (Method B), based on determination of Risedronate sodium tablet dosage form by RP-HPLC method.  Chromatography separation was carried out on a C18 (150X4.6 mm x5 µ) SS Column using Methanol: Ammonium formate (85:15) as the mobile phase at a flow rate of   1.0 ml/min. The chromatographic analysis was carried out in the reflectance and absorbance mode at 254 nm and retention time of the drug was found to be 1.11 ml/min for standard and tablet. Linear responses of the drug were in the concentration range of 200-1000 µg/ml. The accuracy of the method was assessed by standard dilution method and found to be 98% to              102% .The results of the analysis were validated statistically prism software. The method established was found to be simple, precise, linear, accurate and sensitive. The developed method can be used for routine quality control analysis of Risedronate sodium in pure and pharmaceutical dosage form.


2020 ◽  
Vol 10 (4) ◽  
pp. 97-101
Author(s):  
Mithun Rudrapal ◽  
Nazim Hussain

A simple, precise and accurate RP-HPLC method was developed and validated for the estimation of gemifloxacin in the tablet dosage form. The separation was achieved on a reversed-phase C-18 column (250 x 4.6 mm i.d., 5 µm) using a mobile phase consisting of acetonitrile/acetate buffer of pH 4.5 (70:30 v/v) at a flow rate of 1.0 ml/min and a detection wavelength of 244 nm. The separation was carried out on an isocratic mode at room temperature. The method was validated as per ICH guidelines for linearity, accuracy, precision, robustness, LOD, LOQ and specificity. The developed method showed good linearity over the concentration range of 50-150 µg/ml (r2=0.995). The average percentage recovery was 99.77%. The LOD and LOQ were 12.678 µg/ml and 14.261 µg/ml, respectively. Based upon validation studies, the developed method can be successfully applied for the routine analysis of gemifloxacin in bulk drugs as well as pharmaceutical dosage forms. Keywords: Gemifloxacin, Tablet dosage form, RP-HPLC, Validation, ICH guidelines


2020 ◽  
Vol 10 (6) ◽  
pp. 6610-6618

A Simple, selective, accurate, precise, linear, and stability-indicating RP-HPLC method was developed and validated for the estimation of Cinacalcet hydrochloride in bulk and tablet dosage forms. Chromatographic separation was achieved on X-Terra Symmetry C18 (4.6 x 150mm; 5 m) with mobile phase containing Phosphate buffer: Acetonitrile (40:60 v/v) pH adjusted to 3.0 ±0.05 with diluted ortho-phosphoric acid. The flow rate was maintained at 0.9 mL/min. The eluent was monitored at 282 nm. Moreover, the retention time of Cinacalcet was 2.8 minutes. The method was validated for linearity, accuracy, precision, and robustness as per ICH guidelines. The developed method was found linear between 25-150 μg/ml, and the linear regression coefficient was 0.999. The % RSD values are less than 2 % indicating the accuracy and precision of the method. The percentage of recovery was obtained from 98-102%. The system suitability parameters were found to be within the limit. Forced degradation studies were conducted under various conditions. The proposed method is simple, rapid, precise, and accurate. It can be used for the quantitation of Cinacalcet hydrochloride in bulk and commercial pharmaceutical dosage forms.


Author(s):  
Sonalika Patro ◽  
S. Harshith Kumar ◽  
M. Barath kumar ◽  
E. Masthaniah ◽  
K. Sairam ◽  
...  

A Simple, accurate and precise method was developed and validated for the determination of flucloxacillin sodium in its tablet dosage form. The separation was eluted on xterra c18 column (4.6x150mm, 5micron) using a mixture of octane buffer and methanol as mobile phase in a ratio of (30:70) which was pumped through column at a flow rate of  1ml/min. Optimised wavelength for flucloxacillin was 237nm, the retention time was 2.305minutes and the percentage purity was found to be 98.14%. System suitability parameters such as theoretical plate and tailing factor for flucloxacillin sodium was found to be 2991.64 and 1.90 respectively, the proposed method was validated as per ICH guidelines (ICH, Q2 AND (R1)) the method was found to be linear at the concentration range of 20-100µg/ml and the correlation coefficient (r2) value was found to be 0.9994 percentage RSD for precision was 0.9% and percentage RSD for ruggedness was 0.5%. The precision study was precise, robust and repeatable. The LOD and LOQ values are 2.98 and 9.98 respectively. Hence the suggested RP-HPLC method can be used for routine analysis for flucloxacillin sodium in tablet dosage form.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Shilpi Pathak ◽  
Pradeep Mishra

Abstract Background A stability-indicating RP-HPLC method was developed and validated for the estimation of empagliflozin drug and its tablet dosage form using a DAD detector. The mobile phase consisted of methanol/acetonitrile/0.1%OPA (75:20:5). The peak was observed at 2.54 min using 222.0 nm absorption maxima. Results Calibration curve plot was found within the range of 10–50 µg/mL. The coefficient of determination (R2) was found to be 0.9990. Forced degradation studies were performed for the empagliflozin in various conditions, and the results were calculated as %RSD values and were found to be within the limits. Conclusion The method was validated as per ICH guidelines with respect to all validation parameters.


Sign in / Sign up

Export Citation Format

Share Document