magnetic field imaging
Recently Published Documents


TOTAL DOCUMENTS

95
(FIVE YEARS 30)

H-INDEX

11
(FIVE YEARS 1)

2021 ◽  
Vol 63 (12) ◽  
pp. 704-711
Author(s):  
Nvjie Ma ◽  
Xiangdong Gao ◽  
Congyi Wang ◽  
Yanxi Zhang

To overcome the shortcomings of existing magneto-optical imaging, such as the saturation of an image under a constant magnetic field and the ambiguity of an image under an alternating magnetic field, imaging using a combined magnetic field is presented in this research. Weld defect samples include a laser-cut groove, a wire-cut penetrating groove, a pit and a Z-shaped crack. Magneto-optical imaging experiments were carried out under different magnetic fields. Contour extraction and standard deviation calculations were carried out for all magneto-optical images and the maximum standard deviation of the laser-cut groove under an alternating magnetic field was 20.9, which was less than the maximum value of 37.4 under a combined magnetic field. The experimental results show that the contrast of a magneto-optical image obtained under the combined magnetic field is greater than that obtained under the alternating magnetic field for all defects. The proposed combined magnetic field could optimise the magneto-optical imaging effect for weld defects under the existing excitation method to a certain extent.


Author(s):  
Estefani Marchiori ◽  
Lorenzo Ceccarelli ◽  
Nicola Rossi ◽  
Luca Lorenzelli ◽  
Christian L. Degen ◽  
...  

2021 ◽  
Vol 11 (17) ◽  
pp. 8148
Author(s):  
Yuan Chen ◽  
Ping Lai ◽  
Hong-Zhong Huang ◽  
Peng Zhang ◽  
Xiaoling Lin

With the development of 3D integrated packaging technology, failure analysis is facing more and more challenges. Defect localization in a 3D package is a key step of failure analysis. The complex structure and materials of 3D package devices demand non-destructive defect localization technology for full packages. Magnetic field imaging and three-dimensional X-ray technology are not affected by package material or form. They are effective methods to realize defect localization on 3D packages. In this paper, magnetic field imaging and high-resolution three-dimensional X-ray microscopy were used to localize the open defect in a 3D package with a TSV daisy chain. A two-probe RF method in magnetic field imaging was performed to resolve isolation of the defect difficulties resulting from many different branches of TSV daisy chains. Additionally, a linear decay method was used to target sub-micron resolution at a long working distance. Multiple partition scans from a high-resolution 3D X-ray microscopy with a two-stage magnification structure were used to achieve sub-micron resolution. The open location identified by magnetic field imaging was consistent with that identified by a three-dimensional X-ray microscope. The opening was located on the top metal in the proximity of the fifth via. Physical failure analysis revealed the presence of a crack in the top metal at the opening location.


2021 ◽  
Vol 507 ◽  
pp. 230292
Author(s):  
Felix Brauchle ◽  
Florian Grimsmann ◽  
Otto von Kessel ◽  
Kai Peter Birke

AIP Advances ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 055314
Author(s):  
T. J. Gilbert ◽  
K. J. Stevenson ◽  
M. C. Paul ◽  
T. E. Steinberger ◽  
E. E. Scime

2021 ◽  
Vol 60 (5) ◽  
pp. 056502
Author(s):  
Shogo Suzuki ◽  
Hideaki Okada ◽  
Kai Yabumoto ◽  
Seiju Matsuda ◽  
Yuki Mima ◽  
...  

2021 ◽  
Vol 92 (3) ◽  
pp. 035113
Author(s):  
Huan Liu ◽  
Changfeng Zhao ◽  
Xiaobin Wang ◽  
Zehua Wang ◽  
Jian Ge ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document