measured energy
Recently Published Documents


TOTAL DOCUMENTS

172
(FIVE YEARS 25)

H-INDEX

24
(FIVE YEARS 4)

Author(s):  
Amir Y. Kamel ◽  
Laura Robayo ◽  
Debbie Liang ◽  
Martin D. Rosenthal ◽  
Chasen A. Croft ◽  
...  

2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Philip Agee ◽  
Leila Nikdel ◽  
Sydney Roberts

AbstractThis paper provides an open dataset of measured energy use, solar energy production, and building air leakage data from a 328 m2 (3,531 ft2) all-electric, zero energy commercial building in Virginia, USA. Over two years of energy use data were collected at 1-hour intervals using circuit-level energy monitors. Over six years of solar energy production data were measured at 1-hour resolution by 56 microinverters (presented as daily and monthly data in this dataset). The building air leakage data was measured post-construction per ASTM-E779 Standard Test Method for Determining Air Leakage Rate by Fan Pressurization and the United States Army Corps (USACE) Building Enclosure Testing procedure; both pressurization and depressurization results are provided. The architectural and engineering (AE) documents are provided to aid researchers and practitioners in reliable modeling of building performance. The paper describes the data collection methods, cleaning, and convergence with weather data. This dataset can be employed to predict, benchmark, and calibrate operational outcomes in zero energy commercial buildings.


Author(s):  
I.Yu. Chernіavskіy ◽  
V.P. Starenky ◽  
A.S. Makienko ◽  
L.O. Averyanova ◽  
O.O. Petrychenko ◽  
...  

Background. Radiation protection of patients undergoing radiation therapy using linear electron accelerators is based on ensuring the constancy of the equipment parameters set during commissioning. Therefore, studying the possibility of operational assessment of the spectrum characteristics consistency of the generated bremsstrahlung is a priority along with standard dosimetric parameter control procedures. Primarily, this refers to specifying the average measured energy of bremsstrahlung which provides an impartial assessment of the constancy of the whole wave path of the accelerator. However, there is no special diagnostic equipment to determine this parameter. At the same time, the literature data represent a growing interest in the use of CdTe sensors for the analysis of high-energy radiation, including the ones in medical accelerators. Purpose – developing and testing special diagnostic equipment based on semiconductor CdTe sensors, which would implement the assessment of the average measured energy of bremsstrahlung of the medical accelerator 6 MeV via comparing the mass attenuation coefficients in lead and aluminum. Materials and Methods. The paper deals with experimental evaluation of the Varian Clinac 600C linear accelerator (USA) spectrum characteristics carried out at Radiation Oncology Department of State Organization «Grigoriev Institute for Medical Radiology and Oncology of the National Academy of Medical Sciences of Ukraine» via determining the average measured energy of bremsstrahlung. The assessment of the average measured energy of the bremsstrahlung of the accelerator was performed based on comparing two mass attenuation coefficients of radiation with materials having significantly different atomic numbers, i.e. Al and Pb. The assessment of the mass attenuation coefficients was performed on the basis of measuring the average amplitudes of CdTe signals of the sensor, operating in the pulse mode in conjunction with a 16-bit ADC. Pulses of bremsstrahlung from the linear accelerator were recorded by a peak detector for 10 seconds of measurement by the hardware-software complex at 400 monitor units by CdTe sensor with aluminum and lead absorber. The study was performed at a distance of «source-surface» 100 cm with an area of the irradiation field of 20x20 cm. The spectral energy profile of the generated field of bremsstrahlung was studied. Results. The developed equipment was tested by CdTe sensor, which was created taking into account the energy sensitivity of the sensor itself as well as the spectraltemporal characteristics of the pulsed radiation of the accelerator. The approach dealing with assessing the average measured energy of bremsstrahlung of the linear electron accelerator, based on the dependence of the attenuation of radiation by the absorber layer on the radiation energy, has been experimentally confirmed. The theoretical dependence of the average measured energy of bremsstrahlung of the linear accelerator on the ratio of the mass attenuation coefficients of lead and aluminum has been obtained. The energy range from 0.1 to 6 MeV corresponds to the ratio of mass absorption coefficients of lead to aluminum, varying nonlinearly from 33.8 to 1.639. The average measured energy of the linear accelerator of 0.8 MeV corresponds to a mass coefficient ratio of about 1.23 for these materials. The assessed absolute error (from the set value during commissioning the linear accelerator) of the specified measured average energy of bremsstrahlung is up to 12.5% (0.72 MeV), corresponding to the ratio of mass attenuation coefficients – 1.340. Conclusions. The special diagnostic equipment for recording the spectrum characteristics of the Varian Clinac 600C linear accelerator (USA) based on semiconductor CdTe sensors, which along with 16-bit ADC make it possible to estimate the average measured energy of bremsstrahlung via comparing mass attenuation coefficients in Al and Pb has been substantiated and reduced to practice. The assessment of mass attenuation coefficients is carried out based on measuring the average amplitudes of pulses of СdTe sensors operating in a pulse mode.


Author(s):  
Philip Agee ◽  
Leila Nikdel ◽  
Sydney Roberts

This paper provides an open dataset of measured energy use, solar energy production, and building air leakage data from a 328 m2 (3,531 ft2) all-electric, zero energy commercial building in Virginia, USA. Over two years of energy use data were collected at 1-hour intervals using circuit-level energy monitors. Over six years of solar energy production data were measured at 1-hour intervals by 56 microinverters. The building air leakage data was measured post-construction per ASTM-E779 Standard Test Method for Determining Air Leakage Rate by Fan Pressurization and the United States Army Corps (USACE) Building Enclosure Testing procedure; both pressurization and depressurization results are provided. The architectural and engineering (AE) documents are provided to aid researchers and practitioners in reliable modelling of building performance. The paper describes the data collection methods, cleaning, and convergence with weather data. This dataset can be employed to predict, benchmark, and calibrate operational outcomes in zero energy commercial buildings.


2021 ◽  
Vol 102 (4) ◽  
pp. e11
Author(s):  
Stephanie Silveira ◽  
Barbara Gower ◽  
Tapan Mehta ◽  
Brenda Jeng ◽  
Robert Motl

2020 ◽  
Vol 4 (Supplement_1) ◽  
pp. 179-179
Author(s):  
Qu Tian ◽  
Nancy Glynn ◽  
Rebecca Ehrenkranz ◽  
Briana Sprague ◽  
Andrea Rosso ◽  
...  

Abstract Energy is an important concept in human health and diseases. Self-reported energy has been described as “the individual’s potential to perform physical and mental activity” and “the individual’s energy availability”. However, little empirical data exists on whether self-reported energy level is related to objectively measured energy level. Prior research suggests that more energy availability is associated with higher physical activity level. It remains unclear whether self-reported energy availability would be associated with objectively measured energy level, such as active energy expenditure and total energy expenditure. Using data from the Health, Aging and Body Composition Study, we identified 94 participants (mean age=86.2±2.4 y/o, 46%blacks, 52%women) with concurrent data on self-reported energy (scale 0-10) and objective energy level by the SenseWear Armband. We examined cross-sectional associations of self-reported energy with objectively measured energy and physical activity levels using Spearman correlation. Greater self-reported energy level was associated with higher daily active energy expenditure in kcal (r=0.30,p=0.004), higher METs (r=0.33,p<0.001), more minutes of physical activity (r=0.35,p<0.001), and more step counts (r=0.36,p<0.001). Self-reported energy was not associated with total energy expenditure (p=0.87) or estimated resting metabolic rate (p=0.53). Self-reported energy may reflect an individual’s activity energy expenditure but not total energy expenditure. It further supports the hypothesis that energy availability even by self-report connects to physical activity behavior. Whether self-reported energy correlates with other health outcomes warrants further investigation.


2020 ◽  
Vol 224 ◽  
pp. 110244
Author(s):  
Paul Beagon ◽  
Fiona Boland ◽  
Mohammad Saffari

Sign in / Sign up

Export Citation Format

Share Document