anatomic models
Recently Published Documents


TOTAL DOCUMENTS

62
(FIVE YEARS 21)

H-INDEX

13
(FIVE YEARS 2)

Author(s):  
Nicole Wake ◽  
Benjamin Johnson ◽  
Shuai Leng

Author(s):  
Amy E. Alexander ◽  
Nicole Wake
Keyword(s):  

2021 ◽  
Vol 7 (4) ◽  
pp. 420
Author(s):  
Laszlo Jaksa ◽  
Dieter Pahr ◽  
Gernot Kronreif ◽  
Andrea Lorenz

Anatomic models are important in medical education and pre-operative planning as they help students or doctors prepare for real scenarios in a risk-free way. Several experimental anatomic models were made with additive manufacturing techniques to improve geometric, radiological, or mechanical realism. However, reproducing the mechanical behavior of soft tissues remains a challenge. To solve this problem, multi-material structuring of soft and hard materials was proposed in this study, and a three-dimensional (3D) printer was built to make such structuring possible. The printer relies on extrusion to deposit certain thermoplastic and silicone rubber materials. Various objects were successfully printed for testing the feasibility of geometric features such as thin walls, infill structuring, overhangs, and multi-material interfaces. Finally, a small medical image-based ribcage model was printed as a proof of concept for anatomic model printing. The features enabled by this printer offer a promising outlook on mimicking the mechanical properties of various soft tissues.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Mauricio Toro ◽  
Aura Cardona ◽  
Daniel Restrepo ◽  
Laura Buitrago

Abstract Background Material extrusion is used to 3D print anatomic models and guides. Sterilization is required if a 3D printed part touches the patient during an intervention. Vaporized Hydrogen Peroxide (VHP) is one method of sterilization. There are four factors to consider when sterilizing an anatomic model or guide: sterility, biocompatibility, mechanical properties, and geometric fidelity. This project focuses on geometric fidelity for material extrusion of one polymer acrylonitrile butadiene styrene (ABS) using VHP. Methods De-identified computed tomography (CT) image data from 16 patients was segmented using Mimics Innovation Suite (Materialise NV, Leuven, Belgium). Eight patients had maxillary and mandibular defects depicted with the anatomic models, and eight had mandibular defects for the anatomic guides. Anatomic models and guides designed from the surfaces of CT scan reconstruction and segementation were 3D printed in medical-grade acrylonitrile butadiene styrene (ABS) material extrusion. The 16 parts underwent low-temperature sterilization with VHP. The dimensional error was estimated after sterilization by comparing scanned images of the 3D printed parts. Results The average of the estimated mean differences between the printed pieces before and after sterilization were − 0,011 ± 0,252 mm (95%CI − 0,011; − 0,010) for the models and 0,003 ± 0,057 mm (95%CI 0,002; 0,003) for the guides. Regarding the dimensional error of the sterilized parts compared to the original design, the estimated mean differences were − 0,082 ± 0,626 mm (95%CI − 0,083; − 0,081) for the models and 0,126 ± 0,205 mm (95%CI 0,126, 0,127) for the guides. Conclusion This project tested and verified dimensional stability, one of the four prerequisites for introducing vaporized hydrogen peroxide into 3D printing of anatomic models and guides; the 3D printed parts maintained dimensional stability after sterilization.


2020 ◽  
Vol 4 ◽  
pp. 288-297
Author(s):  
Seshiru Nakazawa ◽  
Kimihiro Shimizu ◽  
Natsuko Kawatani ◽  
Kai Obayashi ◽  
Yoichi Ohtaki ◽  
...  
Keyword(s):  