AbstractDetectors using liquid xenon as target are widely deployed in rare event searches. Conclusions on the interacting particle rely on a precise reconstruction of the deposited energy which requires calibrations of the energy scale of the detector by means of radioactive sources. However, a microscopic calibration, i.e. the translation from the number of excitation quanta into deposited energy, also necessitates good knowledge of the energy required to produce single scintillation photons or ionisation electrons in liquid xenon. The sum of these excitation quanta is directly proportional to the deposited energy in the target. The proportionality constant is the mean excitation energy and is commonly known as W-value. Here we present a measurement of the W-value with electronic recoil interactions in a small dual-phase xenon time projection chamber with a hybrid (photomultiplier tube and silicon photomultipliers) photosensor configuration. Our result is based on calibrations at $$\mathcal {O}(1{-}10\,{\hbox {keV}})$$ O ( 1 - 10 keV ) with internal $${^{37}\hbox {Ar}}$$ 37 Ar and $${^{83\text {m}}\hbox {Kr}}$$ 83 m Kr sources and single electron events. We obtain a value of $$W={11.5}{} \, ^{+0.2}_{-0.3} \, \mathrm {(syst.)} \, \hbox {eV}$$ W = 11.5 - 0.3 + 0.2 ( syst . ) eV , with negligible statistical uncertainty, which is lower than previously measured at these energies. If further confirmed, our result will be relevant for modelling the absolute response of liquid xenon detectors to particle interactions.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1215
Author(s):  
Sung Hyun Lee ◽  
Naoki Sunaguchi ◽  
Akie Nagao ◽  
Yoshiyuki Hirano ◽  
Hiroshi Sakurai ◽  
...  

The two-parameter-fitting method (PFM) is commonly used to calculate the stopping-power ratio (SPR). This study proposes a new formalism: a three-PFM, which can be used in multiple spectral computed tomography (CT). Using a photon-counting CT system, seven rod-shaped samples of aluminium, graphite, and poly(methyl methacrylate) (PMMA), and four types of biological phantom materials were placed in a water-filled sample holder. The X-ray tube voltage and current were set at 150 kV and 40 μμA respectively, and four CT images were obtained at four threshold settings. A semi-empirical correction method that corrects the difference between the CT values from the photon-counting CT images and theoretical values in each spectral region was also introduced. Both the two- and three-PFMs were used to calculate the effective atomic number and electron density from multiple CT numbers. The mean excitation energy was calculated via parameterisation with the effective atomic number, and the SPR was then calculated from the calculated electron density and mean excitation energy. Then, the SPRs from both methods were compared with the theoretical values. To estimate the noise level of the CT numbers obtained from the photon-counting CT, CT numbers, including noise, were simulated to evaluate the robustness of the aforementioned PFMs. For the aluminium and graphite, the maximum relative errors for the SPRs calculated using the two-PFM and three-PFM were 17.1% and 7.1%, respectively. For the PMMA and biological phantom materials, the maximum relative errors for the SPRs calculated using the two-PFM and three-PFM were 5.5% and 2.0%, respectively. It was concluded that the three-PFM, compared with the two-PFM, can yield SPRs that are closer to the theoretical values and is less affected by noise.


Anales AFA ◽  
2021 ◽  
Vol 31 (4) ◽  
pp. 157-164
Author(s):  
F.A. Geser ◽  
◽  
M. Valente ◽  

The mean excitation energy <I> is a fundamental quantity in radiation physics, concerning energy deposition in matter and absorbed dose analytical estimations for charged particles. The stopping of swift ions in different materials strongly depends on this parameter among others. This work intends to fill in part, an empty hole in the theory of stopping power: the need of analitically and theoretically assess the hIi-value for materials. The definition of the mean excitation energy using the dielectric response function is analytically integrable if the inelastic cross section parameters are known. Some dielectric models were studied, aimed at calculating the hIi-value for liquid water by theoretical means, reaching the conclusion that a decay of the order of ω −2 in frequency (energy) is needed as weak condition of the optical energy-loss function for the integrals to converge. Afterwards, the first four discrete excitation levels and the diffuse bands for water are treated in a fully analytical scheme, and further compared with numerical results, providing the contribution of these levels to hIi, with the aim of testing the proposed analytical model.


2018 ◽  
Vol 93 (3) ◽  
pp. 301-305 ◽  
Author(s):  
M. Çağatay Tufan ◽  
Zeynep Yüksel

2018 ◽  
Vol 6 ◽  
pp. 20-24 ◽  
Author(s):  
Gloria Vilches-Freixas ◽  
Catherine Therese Quiñones ◽  
Jean Michel Létang ◽  
Simon Rit