stabilization ponds
Recently Published Documents


TOTAL DOCUMENTS

437
(FIVE YEARS 51)

H-INDEX

27
(FIVE YEARS 2)

Author(s):  
Badre Achag ◽  
Hind Mouhanni ◽  
Abdelaziz Bendou

Abstract In many parts of the world, waste stabilization ponds (WSPs) are currently the preferred wastewater treatment method for municipal wastewater. The objective of this research is to examine the performance of a WSP in an arid climate region and to identify ways to improve its purification efficiency so that it can meet the criteria for reuse. The results attributed the poor performance to both improper process and physical design after 12 months of physicochemical and bacteriological analyses, as well as monitoring of operation, maintenance and loading rates. In tertiary treatment, maturation ponds are added, an increase in the capacity of the station, and management of the flow rate and retention time for each pond. By simulating the new WSP with GPS-X, the best pond area ratio obtained is 2.5 m2/capita, with a retention time of 4 days for anaerobic ponds, 20 days for facultative ponds and 3 days for two maturation ponds in series, which is suitable and provides reduction rates of BOD and fecal coliforms of 95 and 99%, respectively, with an average effluent concentration of 20 mg/L and 195 CFU. According to the results, well-maintained WSPs provide a viable, self-sufficient and environmentally friendly wastewater treatment solution for irrigation water supply in dry areas.


Water ◽  
2021 ◽  
Vol 13 (20) ◽  
pp. 2833
Author(s):  
Zhiqiang Gao ◽  
James V. Cizdziel ◽  
Kendall Wontor ◽  
Haitao Lu

Wastewater treatment systems collect and treat sewage that includes microplastics (MPs). However, we are not aware of any studies on the occurrence and distribution of MPs in wastewater stabilization ponds (WSPs), which serve small communities worldwide. Here, we characterized MPs (~45 µm–5 mm) in an aerated WSP serving ~500 houses and an adjacent lake. Putative MPs were most abundant in duckweed (Lemna minor) and sludge (75 ± 22 and 12.8 ± 3.1 particles/g, respectively: ±1 standard deviation (SD), n = 6, dry weight). In the water, average concentrations (particles/L ± 1 SD, n = 6) were highest in the pond (4.1 ± 0.6), followed by effluent (3.9 ± 0.5) and the lake (2.6 ± 0.6). Over 20 types of MPs were identified in each different compartment, with the distribution varying somewhat between the water, sludge, and duckweed. Polyester and polyethylene were the predominant types, followed by polyethylene terephthalate, polyacrylate, polyvinyl chloride, polystyrene, and others. Morphologies consisted of fibers (62–71%), fragments (28–37%), and beads (1–6%). High-density polymers were more frequently found in sludge. Potential sources of the MPs include synthetic textiles from laundry and other plastics washed down household drains. Overall, with ~786,000 MPs/day released in the pond effluent and with duckweed a source of food for waterfowl, we demonstrate that WSPs can be point sources of MPs to both aquatic and terrestrial ecosystems and thus deserve further scrutiny.


Author(s):  
Mohammad Rezvani Ghalhari ◽  
Harald Schönberger ◽  
Behnam Askari Lasaki ◽  
Keyvan Asghari ◽  
Esfandiar Ghordouei Milan ◽  
...  

Author(s):  
Ramazan Vagheei

Abstract Waste Stabilization Ponds (WSPs) are known for the economical treatment of wastewater, especially if low-cost land is available. In this research to overcome some common operational problems such as undesirable color changes in ponds, severe odor problems, and most importantly, deviations from the effluent standards, the performance of a novel installation of a small-scale fine bubble diffused aeration system in the inlet zone of the facultative pond has been investigated. The long-term operational data of the system in two wastewater treatment plants in the east of Iran demonstrated that this system can significantly improve the efficiency of the treatment plant in addition to eliminating the mentioned operational problems. Pre-aeration of the inlet zone of the facultative ponds (Birjand WSPs) by the aeration system consists of 250 fine bubble disk diffusers (12 inches in diameter) and one 22 kW roots blower showed that purple color and odor problem can eliminate after almost two weeks and organic matter removal efficiency increased from 58 ± 15% to about 85 ± 10% based on BOD5. Almost similar results were obtained from the WSPs of Neyshabur. Long-term experimental results showed this system can be used successfully to control the process and upgrade these natural and efficient treatment processes, especially in developing countries.


2021 ◽  
Vol 3 ◽  
Author(s):  
Yannan Huang ◽  
Colin M. Ragush ◽  
Lindsay H. Johnston ◽  
Michael W. Hall ◽  
Robert G. Beiko ◽  
...  

Wastewater stabilization ponds (WSPs) are commonly used to treat municipal wastewater in the Canadian Arctic. Bacterial community structure and functionality remain mostly uncharacterized for arctic WSPs, yet are presumed important for treatment outcomes during the 3-month summer treatment season with open water in the WSPs. The objective of this study was to investigate treatment performance and related temporal and spatial changes in the structure and putative function of bacterial communities during treatment of municipal wastewater in the WSPs of Pond Inlet and Clyde River, Nunavut over two consecutive summer treatment seasons. Influent raw wastewater contained a high organic load and large bacterial communities (~9 log 16S rRNA copies/mL) belonging mainly to Proteobacteria. Although designed to be facultative ponds, both WSPs remained anaerobic with neutral pH values (7.5–7.8) throughout the summer treatment season. Water quality data showed that nutrients [measured as carbonaceous biological oxygen demand (CBOD5)], total suspended solids, and total ammonia nitrogen were progressively reduced during treatment in the ponds as the summer progressed. The pond bacterial population size and species richness depended on the pond temperature (2–18°C), with 8.5 log 16S rRNA copies/mL and the largest alpha diversities (Shannon-Wiener index of 4-4.5) observed mid-season (late July). While the phylogenetic beta diversity in raw wastewater from the two locations remained similar, pond bacterial communities underwent significant (p < 0.05) changes to dominance of Comamonadaceae, Geobacteracea, and Porphyromonadaceae. Multivariate distance based redundancy analysis and predicted gene functionalities in the microbiota agreed with water quality results that microbial removal of nutrients (e.g., CBOD5) peaked in the middle of the summer coinciding with the treatment period with the highest pond temperatures. Information from this study will be useful for further development of models to predict biological treatment outcomes, which could be used to size and assess the feasibility of WSPs in extreme climates. Higher pond temperatures resulted in optimal biological processes and nutrient removal in the middle of the summer. While it is challenging to control environmental factors in a passive wastewater treatment system there are some design considerations that could be used to optimize temperature regimes, such as the depth of the pond.


Author(s):  
Bruno Rodrigues dos Santos ◽  
Roselene Maria Schneider ◽  
Adriana Garcia do Amaral ◽  
Milene Carvalho Bongiovani ◽  
Ednaldo Antonio de Andrade

Effluents generated in landfills are difficult to treat and require different forms of treatment to reach the necessary polishing for disposal. Leachate is usually treated in stabilization ponds where pollutants are significantly removed, but it might not be enough for disposal. Thus, we aimed at evaluating the applicability of the natural coagulant Tanfloc SG and the chemical coagulant PAC, with the addition of the anionic flocculation auxiliary polymer (PA), in the coagulation / flocculation processes as a post-treatment of landfill effluents. The tests were carried out by means of a jar test, with coagulant dosage ranging from 0 - 1,250 mg.L-1 and pH values ranging from 5 - 9, in three decantation times. The results showed that both Tanfloc SG and PAC are efficient in clarifying the effluents, even though they act well in different dosage values of coagulants and pH. The polymer dosage did not generate significant improvements in the variations of the variables studied, however, in some experiments it was shown to expand removal range in regards to some variables. The PAC coagulant showed to be efficient in the removal of suspended solids, dissolved materials, colloidals and humic substances, and Tanfloc SG acted mainly in the removal of solids. 


Sign in / Sign up

Export Citation Format

Share Document