Introduction: To investigate the relationship between the choroidal circulation and glaucoma, assessing macular choroidal thickness (MCT) as a predictive value of glaucomatous visual field damage. Methods: Twenty primary open-angle glaucoma patients were recruited. Patients underwent two SS-OCTs scans: one with DRI OCT (Topcon) and the other with PLEX Elite 9000 (Zeiss). Standard OCT parameters were acquired by DRI OCT, while MCT was manually measured in 5 points on Plex ELITE 9000 images. The relationship among MCT, standard OCT parameters and visual field indices were evaluated. Pearson’s r correlation was calculated to evaluate these relationships. Reproducibility of measurements was analyzed. Results: MCT measurements showed a good intra- and inter-observer repeatability. A negative correlation appeared between MCT and body mass index (BMI) (r = -0.518, p=0.023). Mean deviation showed a statistically significant correlation with MCT measured at sub-foveal and at 1000 µm nasally (r = 0.50, p=0.03 and r = 0.52, p=0.023). A correlation was found between the two MCT (Zeiss vs Topcon) measurements and between MCT and peripapillary choroidal thickness (r = 0.944 and r = 0.740, p<0.001, respectively). Conclusions: A good intra- and inter-observer reproducibility was found. MCT showed a weak predictive value of glaucomatous visual field damage. A significant correlation was found between MCT and BMI.



2021 ◽  
Vol 10 (6) ◽  
pp. 1180
Author(s):  
Sai Karthik Kodeboyina ◽  
Tae Jin Lee ◽  
Kathryn Bollinger ◽  
Lane Ulrich ◽  
David Bogorad ◽  
...  

Purpose: The purpose of this study was to discover the aqueous humor proteomic changes associated with visual field indices in glaucoma patients. Methods: Aqueous humor samples were analyzed using Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS). The visual fields were analyzed with the Humphrey Visual Field analyzer. Statistical analyses were performed to discover the relationship between the aqueous humor proteins and visual field parameters including Pattern Standard Deviation (PSD), Visual Field Index (VFI), Mean Deviation (MD) and Glaucoma Hemifield Test (GHT). Results: In total, 222 proteins were identified in 49 aqueous humor samples. A total of 11, 9, 7, and 6 proteins were significantly correlated with PSD, VFI, MD, and GHT respectively. These proteins include apolipoprotein D, members of complement pathway (C1S, C4A, C4B, C8B, and CD14), and immunoglobulin family (IKHV3-9, IGKV2-28). Conclusion: Several proteins involved in immune responses (immunoglobulins and complement factors) and neurodegeneration (apolipoprotein D) were identified to be associated with abnormal visual field parameters. These findings provide targets for future studies investigating precise molecular mechanisms and new therapies for glaucomatous optic neuropathy.





2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Theresa Theilig ◽  
Matus Rehak ◽  
Catharina Busch ◽  
Caroline Bormann ◽  
Marc Schargus ◽  
...  

Abstract The aim of this study was to compare the efficacy and safety profile of XEN microstent implantation with trabeculectomy (TET) in a comparable group of open-angle glaucoma cases in a retrospective, monocentric, single-surgeon setting. Each treatment group consisted of 100 eyes of 100 patients. At regular follow-up visits during the first 12 months after surgery, the following assessments were conducted and compared: intraocular pressure (IOP), number of IOP-lowering medications applied, best-corrected visual acuity (BCVA) and visual field testing. In both groups mean IOP was significantly reduced (p < 0.001). Mean IOP dropped from 24.8 ± 7.8 to 14.8 ± 4.0 mmHg in the TET and from 24.5 ± 6.7 to 16.6 ± 4.8 mmHg in the XEN group. The number of active compounds in the prescribed medication dropped from 3.3 ± 1.2 to 1.3 ± 1.4 in the TET and from 3.0 ± 1.1 to 1.4 ± 1.5 in the XEN group. BCVA and mean defect of static automated perimetry did not show a change of statistical significance in either group. Complications were more frequent after TET (p = 0.005) while postoperative needling was more frequent in the XEN group (p = 0.021). TET and XEN led to a significant reduction of IOP and IOP-lowering medication, while BCVA and visual field indices remained mostly unaltered over a 12-month postsurgical follow-up.



2020 ◽  
Vol 9 (8) ◽  
pp. 2382
Author(s):  
Ewa Kosior-Jarecka ◽  
Anna Pankowska ◽  
Piotr Polit ◽  
Andrzej Stępniewski ◽  
Mark Roger Symms ◽  
...  

The aim of the study was to assess the volume of the lateral geniculate nucleus (LGN) in patients with open-angle glaucoma in 7Tesla MRI and to evaluate its relation to RNFL thickness and VF indices. Material and methods. The studied group consisted of 20 open-angle glaucoma patients with bilaterally the same stage of glaucoma (11 with early glaucoma and nine with advanced glaucoma) and nine healthy volunteers from the Department of Diagnostics and Microsurgery of Glaucoma, Medical University of Lublin, Poland. Circumpapillary RNFL-thickness measurements were performed using OCT in all patients and visual fields were performed in the glaucoma group. A 7Tesla MRI was performed to assess the volume of both lateral geniculate bodies. Results. The LGN volume varied significantly between groups from 122.1 ± 14.4 mm3 (right LGN) and 101.6 ± 13.3 mm3 (left LGN) in the control group to 80.2 ± 17.7 mm3 (right LGN) and 71.8 ± 14.2 mm3 (left LGN) in the advanced glaucoma group (right LGN p = 0.003, left LGN p = 0.018). However, volume values from early glaucoma: right LGN = 120.2 ± 26.5 mm3 and left LGN = 103.2 ± 28.0 mm3 differed significantly only from values from the advanced group (right LGN p = 0.006, left LGN p = 0.012), but not from controls (right LGN p = 0.998, left LGN p = 0.986). There were no significant correlations between visual field indices (MD (mean deviation) and VFI (visual field index)) and LGN volumes in both glaucoma groups. Significant correlations between mean RNFL (retinal nerve fiber layers) thickness and corresponding and contralateral LGN were observed for the control group (corresponding LGN: p = 0.064; contralateral LGN: p = 0.031) and early glaucoma (corresponding LGN: p = 0.017; contralateral LGN: p = 0.008), but not advanced glaucoma (corresponding LGN: p = 0.496; contralateral LGN: p = 0.258). Conclusions. The LGN volume decreases in the course of glaucoma. These changes are correlated with RNFL thickness in early stages of glaucoma and are not correlated with visual field indices.



Author(s):  
Hsin-Hao Yu ◽  
Stefan R. Maetschke ◽  
Bhavna J. Antony ◽  
Hiroshi Ishikawa ◽  
Gadi Wollstein ◽  
...  




2017 ◽  
Vol 102 (8) ◽  
pp. 1054-1059 ◽  
Author(s):  
Maximilian Pfau ◽  
Moritz Lindner ◽  
Julia S Steinberg ◽  
Sarah Thiele ◽  
Christian K Brinkmann ◽  
...  

Background/AimsTo analyse the retest reliability of visual field indices and to describe patterns of visual field deficits in mesopic and dark-adapted two-colour fundus-controlled perimetry (FCP) in macular diseases.MethodsSeventy-seven eyes (30 eyes with macular diseases and 47 normal eyes) underwent duplicate mesopic and dark-adapted two-colour FCP (Scotopic Macular Integrity Assessment, CenterVue). Non-weighted (mean defect, loss variance), variability-weighted (mean deviation, pattern standard deviation (PSD)) and graphical (cumulative defect (Bebie) curves) indices were computed. Reproducibility (coefficient of repeatability, CoR) of these indices was assessed. Cluster analysis was carried out to identify patterns of visual field deficits.ResultsThe intrasession reproducibility was lower for the mean defect as compared with the mean deviation (CoR (dB) 2.67 vs 2.57 for mesopic, 1.71 vs 1.45 for dark-adapted cyan, 1.94 vs 1.87 for dark-adapted red testing) and lower for the square-root loss variance as compared with the PSD (CoR (dB) 1.48 vs 1.34, 0.77 vs 0.65, 1.23 vs 1.03). Hierarchical cluster analysis of the indices disclosed six patterns of visual field deficits (approximately unbiased P value>0.95) with varying degrees of global versus focal defect and rod versus cone dysfunction. These were also reflected by the cumulative defect curves.ConclusionFCP with mesopic and dark-adapted two-colour testing allows for reproducible assessment of different types of retinal sensitivity, whereby mean deviation and PSD exhibited the better retest reliability of the tested indices. Distinct patterns of retinal dysfunction can be identified using this setup, reflecting variable degrees of rod and cone dysfunction in different macular diseases. Dark-adapted two-colour FCP provides additional diagnostic information and allows for refined structure–function correlation in macular diseases.