pupillary light reflex
Recently Published Documents


TOTAL DOCUMENTS

332
(FIVE YEARS 71)

H-INDEX

34
(FIVE YEARS 4)

Author(s):  
Ana Maria Portugal ◽  
Mark J. Taylor ◽  
Charlotte Viktorsson ◽  
Pär Nyström ◽  
Danyang Li ◽  
...  

2021 ◽  
Vol 62 (15) ◽  
pp. 23
Author(s):  
Agnieszka Zielińska ◽  
Piotr Ciąćka ◽  
Maciej Szkulmowski ◽  
Katarzyna Komar

Author(s):  
Joel T. Martin ◽  
Joana Pinto ◽  
Daniel Bulte ◽  
Manuel Spitschan

AbstractWe introduce PyPlr—a versatile, integrated system of hardware and software to support a broad spectrum of research applications concerning the human pupillary light reflex (PLR). PyPlr is a custom Python library for integrating a research-grade video-based eye-tracker system with a light source and streamlining stimulus design, optimisation and delivery, device synchronisation, and extraction, cleaning, and analysis of pupil data. We additionally describe how full-field, homogenous stimulation of the retina can be realised with a low-cost integrating sphere that serves as an alternative to a more complex Maxwellian view setup. Users can integrate their own light source, but we provide full native software support for a high-end, commercial research-grade 10-primary light engine that offers advanced control over the temporal and spectral properties of light stimuli as well as spectral calibration utilities. Here, we describe the hardware and software in detail and demonstrate its capabilities with two example applications: (1) pupillometer-style measurement and parametrisation of the PLR to flashes of white light, and (2) comparing the post-illumination pupil response (PIPR) to flashes of long and short-wavelength light. The system holds promise for researchers who would favour a flexible approach to studying the PLR and the ability to employ a wide range of temporally and spectrally varying stimuli, including simple narrowband stimuli.


Author(s):  
Anton Sonntag ◽  
Carina Kelbsch ◽  
Ronja Jung ◽  
Helmut Wilhelm ◽  
Torsten Strasser ◽  
...  

Abstract Purpose To assess the effect of central and peripheral stimulation on the pupillary light reflex. The aim was to detect possible differences between cone- and rod-driven reactions. Methods Relative maximal pupil constriction amplitude (relMCA) and latency to constriction onset (latency) to cone- and rod-specific stimuli of 30 healthy participants (24 ± 5 years (standard deviation)) were measured using chromatic pupil campimetry. Cone- and rod-specific stimuli had different intensities and wavelengths according to the Standards in Pupillography. Five filled circles with radii of 3°, 5°, 10°, 20° and 40° and four rings with a constant outer radius of 40° and inner radii of 3°, 5°, 10° and 20° were used as stimuli. Results For cone-and rod-specific stimuli, relMCA increased with the stimulus area for both, circles and rings. However, increasing the area of a cone-specific ring by minimizing its inner radius with constant outer radius increased relMCA significantly stronger than the same did for a rod-specific ring. For cones and rods, a circle stimulus with a radius of 40° created a lower relMCA than the summation of the relMCAs to the corresponding ring and circle stimuli which combined create a 40° circle-stimulus. Latency was longer for rods than for cones. It decreased with increasing stimulus area for circle stimuli while it stayed nearly constant with increasing ring stimulus area for cone- and rod-specific stimuli. Conclusion The effect of central stimulation on relMCA is more dominant for cone-specific stimuli than for rod-specific stimuli while latency dynamics are similar for both conditions.


2021 ◽  
Author(s):  
Weizhen Xie ◽  
Weiwei Zhang

Our visual experience often varies based on momentary thoughts and feelings. For example,when positive thoughts are invoked, visual objects may appear brighter. However, it remainsunclear whether this phenomenological experience is driven by a genuine top-down modulation of brightness perception or by a mere response bias. To investigate this issue, here we use pupillometry as a more objective measure of perceived brightness. We asked participants to judge the brightness level of an iso-luminant gray color patch after evaluating the valence of a positive or negative word. We found that the gray color patch elicited greater pupillary light reflex and more frequent “bright” responses after observers had evaluated the valence of a positive word. As pupillary light reflex is unlikely driven by voluntary control or response bias, these results suggest that positive concepts can genuinely modulate brightness perception.


Life ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 1104
Author(s):  
Frederick Robert Carrick ◽  
Sergio F. Azzolino ◽  
Melissa Hunfalvay ◽  
Guido Pagnacco ◽  
Elena Oggero ◽  
...  

The size of our pupils changes continuously in response to variations in ambient light levels, a process known as the pupillary light reflex (PLR). The PLR is not a simple reflex as its function is modulated by cognitive brain function and any long-term changes in brain function secondary to injury should cause a change in the parameters of the PLR. We performed a retrospective clinical review of the PLR of our patients using the BrightLamp Reflex iPhone app. The PLR variables of latency, maximum pupil diameter (MaxPD), minimum pupil diameter (MinPD), maximum constriction velocity (MCV), and the 75% recovery time (75% PRT) were associated with significant differences between subjects who had suffered a concussion and those that had not. There were also significant differences in PLR metrics over the life span and between genders and those subjects with and without symptoms. The differences in PLR metrics are modulated not only by concussion history but also by gender and whether or not the person has symptoms associated with a head injury. A concussive injury to the brain is associated with changes in the PLR that persist over the life span, representing biomarkers that might be used in clinical diagnosis, treatment, and decision making.


2021 ◽  
Author(s):  
Julia l.a Woodall ◽  
Jordyn a Sak ◽  
Kyle R Cowdrick ◽  
Brady m Bove Muñoz ◽  
Jessica h McElrath ◽  
...  

ABSTRACT Introduction Occupational exposure to repetitive, low-level blasts in military training and combat has been tied to subconcussive injury and poor health outcomes for service members. Most low-level blast studies to date have focused on explosive breaching and firing heavy weapon systems; however, there is limited research on the repetitive blast exposure and physiological effects that mortarmen experience when firing mortar weapon systems. Motivated by anecdotal symptoms of mortarmen, the purpose of this paper is to characterize this exposure and its resulting neurocognitive effects in order to provide preliminary findings and actionable recommendations to safeguard the health of mortarmen. Materials and Methods In collaboration with the U.S. Army Rangers at Fort Benning, blast exposure, symptoms, and pupillary light reflex were measured during 3 days of firing 81 mm and 120 mm mortars in training. Blast exposure analysis included the examination of the blast overpressure (BOP) and cumulative exposure by mortarman position, as well as comparison to the 4 psi safety threshold. Pupillary light reflex responses were analyzed with linear mixed effects modeling. All neurocognitive results were compared between mortarmen (n = 11) and controls (n = 4) and cross-compared with blast exposure and blast history. Results Nearly 500 rounds were fired during the study, resulting in a high cumulative blast exposure for all mortarmen. While two mortarmen had average BOPs exceeding the 4 psi safety limit (Fig. 2), there was a high prevalence of mTBI-like symptoms among all mortarmen, with over 70% experiencing headaches, ringing in the ears, forgetfulness/poor memory, and taking longer to think during the training week (n ≥ 8/11). Mortarmen also had smaller and slower pupillary light reflex responses relative to controls, with significantly slower dilation velocity (P < 0.05) and constriction velocity (P < 0.10). Conclusion Mortarmen experienced high cumulative blast exposure coinciding with altered neurocognition that is suggestive of blast-related subconcussive injury. These neurocognitive effects occurred even in mortarmen with average BOP below the 4 psi safety threshold. While this study was limited by a small sample size, its results demonstrate a concerning health risk for mortarmen that requires additional study and immediate action. Behavioral changes like ducking and standing farther from the mortar when firing can generally help reduce mortarmen BOP exposure, but we recommend the establishment of daily cumulative safety thresholds and daily firing limits in training to reduce cumulative blast exposure, and ultimately, improve mortarmen’s quality of life and longevity in service.


2021 ◽  
Vol 8 ◽  
Author(s):  
Joji Kotani ◽  
Hiroyuki Nakao ◽  
Isamu Yamada ◽  
Atsushi Miyawaki ◽  
Naomi Mambo ◽  
...  

Background: Physicians currently measure the pupil diameter and the pupillary light reflex with visual observations using a ruler and a traditional penlight, leading to possibly inaccurate and subjective assessments. Although a mobile pupillometer has been developed and is available in clinical settings, this device can only assess one pupil at a time. Hence, an indirect pupillary light reflex, including those under irradiation to the opposite side of pupil, cannot be evaluated. Consequently, we have developed a new automatic mobile pupilometer, the Hitomiru®, with Hitomiru Co., Ltd. (Tokyo, Japan). This device is a two-glass type pupilometer with a video recording system. The pupil diameter and light reflex of both pupils can be measured simultaneously; therefore, both indirect and direct light reflexes can be assessed.Purpose: To evaluate the clinical ability of the Hitomiru® pupilometer to assess the pupil diameter and the pupillary light reflex of healthy volunteers and patients with intracranial lesions in an intensive care unit (ICU).Methods: Twenty-five healthy volunteers and five ICU patients with intracranial lesions on only the left side were assessed using the Hitomiru® pupilometer. The protocol was as follows: infrared light was applied to both pupils, followed by visible light to the right pupil, infrared light to both pupils, visible light to the left pupil, and then infrared light to both pupils. All the intervals were 2 s, and the dynamics of pupil diameters on both sides were continuously recorded.Results: The healthy adults had approximately 0.5 mm anisocoria, miosis was harder, and mydriasis was less with increased age. There were several differences in miosis rates, miosis times, and mydriasis rates between the healthy adults and the patients with intracranial lesions with both direct irradiation and indirect irradiation.Conclusions: The initial trial estimated and digitally recorded direct and indirect light reflexes, including rapidity of miosis after direct and indirect lights on, and mydriasis after direct and indirect lights off. The Hitomiru® pupilometer was a useful device to digitally record and investigate the relationship between pupil reflexes and intracranial diseases.


Author(s):  
Andrea Kaifie ◽  
Martin Reugels ◽  
Thomas Kraus ◽  
Michael Kursawe

Abstract Background The PLR (pupillary light reflex) can be a marker for pathological medical conditions, such as neurodegenerative or mental health disorders and diseases as well as marker for physiological alterations, such as age, sex or iris color. PLR alterations have been described in people after alcohol consumption, as well. However, the effect of sleep deprivation on PLR parameters is still under debate. Methods The aim of this study was to investigate the feasibility of PLR measurements in sleep-deprived and alcohol-exposed participants. In addition, we wanted to identify PLR parameters that were altered by sleep deprivation and alcohol exposure. Results Altogether n = 50 participants have been included in this study. Differences in the PLR parameters initial diameter (dinit), latency (∆tlat), acceleration (∆ta), contraction velocity (ϑcon), quarter dilatation velocity (ϑ1/4dil), half dilatation time (∆t1/2), and the line integral (L(0.3500)) have been evaluated between baseline, sleep deprivation, as well as alcohol exposure. In a generalized linear mixed models design, we could observe statistically significant associations between the type of exposure and the PLR parameters half dilatation time and half dilatation time after the first light pulse (all p < 0.05). The participants’ latency showed a significant association in dependence of the type of exposure after the second light pulse (p < 0.05). Conclusion Our study delivers first promising results to further develop devices that may identify conditions that impair the ability to work or drive.


Sign in / Sign up

Export Citation Format

Share Document