scholarly journals What Membrane Capacitance?

Author(s):  
Bernard Delalande ◽  
Hirohisa Tamagawa ◽  
Vladimir Matveev

The most common and taught membrane theory assumes that the membrane behaves as a kind of electrical capacitance that is exposed to an electrical current generated by an ionic flow. If this statement is verifiable, it can be confirmed by the laws of physics, mathematics and in particular electricity. We will demonstrate that this hypothesis is not verified and that it is necessary to modify biophysics according to already established and experimentally verified principles of physics.

1994 ◽  
Vol 267 (6) ◽  
pp. S65 ◽  
Author(s):  
J Procopio

Hydraulic analogs of bioelectrical potentials are proposed as teaching tools in helping students with no formal background in physics and mathematics. Membrane capacitance is simulated by a water reservoir, V, whose variable level is the membrane potential. Resting membrane potential is simulated by a large capacitance reservoir of fixed level, connected to reservoir V through a tube having the role of the electrical conductance of the membrane. Injection of electrical current into the cell is simulated by injection of water into the membrane capacitance reservoir. Reversal potentials of the end-plate potential are simulated by another water reservoir, with fixed level (analogous to the reversal potential of the end-plate potential) connected to the membrane capacitance reservoir through a tube corresponding to the acetylcholine-activated ion channels. Different phases of the synaptic potential are then described using the hydraulic analogs. Hydraulic analogs have proved, in our experience, to be an efficient tool in complementing the already established electrical equivalents.


1990 ◽  
Vol 29 (04) ◽  
pp. 282-288 ◽  
Author(s):  
A. van Oosterom

AbstractThis paper introduces some levels at which the computer has been incorporated in the research into the basis of electrocardiography. The emphasis lies on the modeling of the heart as an electrical current generator and of the properties of the body as a volume conductor, both playing a major role in the shaping of the electrocardiographic waveforms recorded at the body surface. It is claimed that the Forward-Problem of electrocardiography is no longer a problem. Several source models of cardiac electrical activity are considered, one of which can be directly interpreted in terms of the underlying electrophysiology (the depolarization sequence of the ventricles). The importance of using tailored rather than textbook geometry in inverse procedures is stressed.


2020 ◽  
Vol 25 (3) ◽  
pp. 415-423
Author(s):  
Ahmed Lachhab ◽  
El Mehdi Benyassine ◽  
Mohamed Rouai ◽  
Abdelilah Dekayir ◽  
Jean C. Parisot ◽  
...  

The tailings of Zeida's abandoned mine are found near the city of Midelt, in the middle of the high Moulouya watershed between the Middle and the High Atlas of Morocco. The tailings occupy an area of about 100 ha and are stored either in large mining pit lakes with clay-marl substratum or directly on a heavily fractured granite bedrock. The high contents of lead and arsenic in these tailings have transformed them into sources of pollution that disperse by wind, runoff, and seepage to the aquifer through faults and fractures. In this work, the main goal is to identify the pathways of contaminated water with heavy metals and arsenic to the local aquifers, water ponds, and Moulouya River. For this reason, geophysical surveys including electrical resistivity tomography (ERT), seismic refraction tomography (SRT) and very low-frequency electromagnetic (VLF-EM) methods were carried out over the tailings, and directly on the substratum outside the tailings. The result obtained from combining these methods has shown that pollutants were funneled through fractures, faults, and subsurface paleochannels and contaminated the hydrological system connecting groundwater, ponds, and the river. The ERT profiles have successfully shown the location of fractures, some of which extend throughout the upper formation to depths reaching the granite. The ERT was not successful in identifying fractures directly beneath the tailings due to their low resistivity which inhibits electrical current from propagating deeper. The seismic refraction surveys have provided valuable details on the local geology, and clearly identified the thickness of the tailings and explicitly marked the boundary between the Triassic formation and the granite. It also aided in the identification of paleochannels. The tailings materials were easily identified by both their low resistivity and low P-wave velocity values. Also, both resistivity and seismic velocity values rapidly increased beneath the tailings due to the compaction of the material and lack of moisture and have proven to be effective in identifying the upper limit of the granite. Faults were found to lie along the bottom of paleochannels, which suggest that the locations of these channels were caused by these same faults. The VLF-EM surveys have shown tilt angle anomalies over fractured areas which were also evinced by low resistivity area in ERT profiles. Finally, this study showed that the three geophysical methods were complementary and in good agreement in revealing the pathways of contamination from the tailings to the local aquifer, nearby ponds and Moulouya River.


2015 ◽  
Vol 11 (1) ◽  
pp. 2897-2908
Author(s):  
Mohammed S.Aljohani

Tomography is a non-invasive, non-intrusive imaging technique allowing the visualization of phase dynamics in industrial and biological processes. This article reviews progress in Electrical Capacitance Volume Tomography (ECVT). ECVT is a direct 3D visualizing technique, unlike three-dimensional imaging, which is based on stacking 2D images to obtain an interpolated 3D image. ECVT has recently matured for real time, non-invasive 3-D monitoring of processes involving materials with strong contrast in dielectric permittivity. In this article, ECVT sensor design, optimization and performance of various sensors seen in literature are summarized. Qualitative Analysis of ECVT image reconstruction techniques has also been presented.


2019 ◽  
Vol 14 (1) ◽  
pp. 75-83
Author(s):  
L. Bouafif ◽  
N. Ellouze

Background: Transcutaneous Electrical Nerve Stimulation (TENS) is a non-invasive pain therapy that uses the sensory effects of an electrical current applied to the skin. Some clinical studies demonstrated that this treatment helps to reduce acute and chronic pains, while others gave sometimes contradictory or uncertain conclusions about the performances of this strategy according to pathology classification. The purpose of this study is the development and evaluation of a new modulated version of transcutaneous electrical nerve stimulation called PWM-TENS. The principle is based on an automatic variation of the stimulation parameters (frequency, amplitude, duration, shape, cyclic ratio) according to the pain evolution. Methods: The study was a controlled clinical trial involving 15 participants, divided into 2 groups. The first experimental group performed modulated PWM-TENS electro-stimulation sessions applied to the painful areas 3 to 4 times a day, for one month. The second control group did parallel treatments by Placebo. The evaluation of the pain intensity is done with the Visual Analog Scale (EVA), the DN4 and SF36 questionnaires. Results: The tests and measurements with our embedded PWM-TENS technique demonstrated that we succeeded to increase the analgesic effect after stopping the stimulation and reduced the pain sensation by about 60%. An improvement in pain intensity scores and questionnaires (EVA, DN4), as well as the quality of life score (SF36), was observed. Also, a reduction of the treatment period from 3 to 1 month was also obtained. Conclusion: The first results clinically observed in the PWM-TENS technique are encouraging. The findings of this study confirm that this noninvasive strategy is suitable and useful for acute pains coming from the nociceptive, neuropathic and musculoskeletal origin. However, its efficiency is moderated and less adapted for low back pain. The experiments make it possible to estimate whether this modulated TENS method could improve existing anti-pain therapies, taking into account objective and subjective evaluation criteria. But this study must be followed by large population samples to answer all the problems of acute and chronic pains.


Author(s):  
David J. Steigmann

This chapter develops two-dimensional membrane theory as a leading order small-thickness approximation to the three-dimensional theory for thin sheets. Applications to axisymmetric equilibria are developed in detail, and applied to describe the phenomenon of bulge propagation in cylinders.


2015 ◽  
Vol 77 (28) ◽  
Author(s):  
MT Masturah ◽  
MHF Rahiman ◽  
Zulkarnay Zakaria ◽  
AR Rahim ◽  
NM Ayob

This paper discussed the design–functionality and application of Flexible Electrical Capacitance Tomography sensor (FlexiECT). The sensors consist of 12 electrodes allocated surrounding the outer layer of the pipeline. The sensor is designed in such that the flexibility features suit the applications in the pipeline of multiple size. This paper also discussed the preliminary result of FlexiECT applications in fluid imaging by identifying the percentage of two mixing fluids.


2000 ◽  
Vol 79 (1) ◽  
pp. 314-320 ◽  
Author(s):  
Luc J. Gentet ◽  
Greg J. Stuart ◽  
John D. Clements

Sign in / Sign up

Export Citation Format

Share Document