Mass spectrometry of organic peroxides

2010 ◽  
pp. 105-127 ◽  
Author(s):  
Helmut Schwarz ◽  
Hans-Martin Schiebel
2004 ◽  
Vol 50 (1) ◽  
pp. 135-140 ◽  
Author(s):  
Jean-Claude Lavoie ◽  
Philippe Chessex ◽  
Thérèse Rouleau ◽  
Diane Migneault ◽  
Blandine Comte

Abstract Background: When solutions of multivitamin preparations (MVPs) are exposed to light, H2O2 as well as organic peroxides are generated and the concentration of vitamin C decreases. The aim of this study was to determine, using mass spectrometry, whether the generation of oxidative byproducts of vitamin C, such as dehydroascorbate (DHA) and 2,3-diketogulonic acid (DKG), accounted for the reported decrease in ascorbic acid in MVPs exposed to light. Methods: Mass spectrometry was used to document the formation of byproducts of ascorbic acid in solutions containing a MVP, vitamin C + riboflavin, and vitamin C + H2O2 + Fe2+. The involvement of ascorbic acid and H2O2 in the formation of organic peroxides was tested by measuring peroxide concentrations in solutions containing H2O2 with or without ascorbic acid and with or without Fe2+ before and after addition of catalase. Results: The loss of ascorbic acid in photo-exposed MVPs was associated with the concomitant generation of byproducts different from DHA and DKG. Among them, one mass fingerprint was particularly observed with solutions of vitamin C + riboflavin exposed to ambient light as well as with the solution of vitamin C + H2O2 + Fe2+, suggesting a Fenton-like reaction. This fingerprint was associated with the formation of catalase-resistant peroxides. Conclusion: Exposure of MVPs to light leads to the rapid loss of ascorbic acid and generation of specific byproducts that differ from DHA and DKG. The conversion of vitamin C into byproducts could be of biological importance in accounting for the decrease in ascorbic acid concentrations and the generation of organic peroxides in light-exposed MVPs.


1968 ◽  
Vol 33 (5) ◽  
pp. 1931-1934 ◽  
Author(s):  
M. Bertrand ◽  
S. Fliszar ◽  
Y. Rousseau

2011 ◽  
Vol 11 (4) ◽  
pp. 1053-1060 ◽  
Author(s):  
Alvaro J. Pena-Quevedo ◽  
James A. Laramee ◽  
H. Dupont Durst ◽  
Samuel P. Hernandez-Rivera

Author(s):  
Philippe Fragu

The identification, localization and quantification of intracellular chemical elements is an area of scientific endeavour which has not ceased to develop over the past 30 years. Secondary Ion Mass Spectrometry (SIMS) microscopy is widely used for elemental localization problems in geochemistry, metallurgy and electronics. Although the first commercial instruments were available in 1968, biological applications have been gradual as investigators have systematically examined the potential source of artefacts inherent in the method and sought to develop strategies for the analysis of soft biological material with a lateral resolution equivalent to that of the light microscope. In 1992, the prospects offered by this technique are even more encouraging as prototypes of new ion probes appear capable of achieving the ultimate goal, namely the quantitative analysis of micron and submicron regions. The purpose of this review is to underline the requirements for biomedical applications of SIMS microscopy.Sample preparation methodology should preserve both the structural and the chemical integrity of the tissue.


Author(s):  
K.K. Soni ◽  
D.B. Williams ◽  
J.M. Chabala ◽  
R. Levi-Setti ◽  
D.E. Newbury

In contrast to the inability of x-ray microanalysis to detect Li, secondary ion mass spectrometry (SIMS) generates a very strong Li+ signal. The latter’s potential was recently exploited by Williams et al. in the study of binary Al-Li alloys. The present study of Al-Li-Cu was done using the high resolution scanning ion microprobe (SIM) at the University of Chicago (UC). The UC SIM employs a 40 keV, ∼70 nm diameter Ga+ probe extracted from a liquid Ga source, which is scanned over areas smaller than 160×160 μm2 using a 512×512 raster. During this experiment, the sample was held at 2 × 10-8 torr.In the Al-Li-Cu system, two phases of major importance are T1 and T2, with nominal compositions of Al2LiCu and Al6Li3Cu respectively. In commercial alloys, T1 develops a plate-like structure with a thickness <∼2 nm and is therefore inaccessible to conventional microanalytical techniques. T2 is the equilibrium phase with apparent icosahedral symmetry and its presence is undesirable in industrial alloys.


Author(s):  
Bruno Schueler ◽  
Robert W. Odom

Time-of-flight secondary ion mass spectrometry (TOF-SIMS) provides unique capabilities for elemental and molecular compositional analysis of a wide variety of surfaces. This relatively new technique is finding increasing applications in analyses concerned with determining the chemical composition of various polymer surfaces, identifying the composition of organic and inorganic residues on surfaces and the localization of molecular or structurally significant secondary ions signals from biological tissues. TOF-SIMS analyses are typically performed under low primary ion dose (static SIMS) conditions and hence the secondary ions formed often contain significant structural information.This paper will present an overview of current TOF-SIMS instrumentation with particular emphasis on the stigmatic imaging ion microscope developed in the authors’ laboratory. This discussion will be followed by a presentation of several useful applications of the technique for the characterization of polymer surfaces and biological tissues specimens. Particular attention in these applications will focus on how the analytical problem impacts the performance requirements of the mass spectrometer and vice-versa.