Miniaturized Optical Sensors for Medical Diagnostics

2014 ◽  
pp. 1557-1584
Author(s):  
Seong-Soo Kim ◽  
Boris Mizaikoff

A new hardware-software complex is proposed for automatic registration, processing and analysis of sedimentation curves in technical or biological suspensions of aggregating micro- or nanoparticles to assess the aging index of the industrial fluids, the state of microbiological suspensions, or medical diagnostics. The complex includes a centrifuge to create an inhomogeneous field of forces that accelerate the settling process. Registration of the sedimentation curves as the height of the column of aggregates in the lower part of the sedimentation tube is carried out using optical sensors. The curves can be taken repeatedly with or without the addition of various substances. The proposed method was tested, and the correspondence of the values ​​of the 1-hour index of erythrocyte sedimentation rate and the 10-minutes centrifuge test was confirmed on a large data set. A three-phase mathematical model of the suspension is developed. This model more accurately describes the dynamics of sedimentation processes compared to the two-phase model. Computer code for the curves processing and calculation of the indices characterizing the state of the suspension is developed. Based on this model a new index is proposed to evaluate the state of suspension. It has advantages because it does not require bringing the test samples to the same concentrations. Using the mathematical model you can determine and the rate of aggregation of suspension particles. As a result a rapid assessment of the aggregation ability of suspension which characterizes the "age" of technical suspension is possible. An example of the use of the complex to assess the indicator of aggregation of red blood cells in order to diagnose the presence of food or drug allergies is given.


2020 ◽  
Vol 2020 ◽  
pp. 1-11
Author(s):  
Shehla Mushtaq ◽  
Nasir M. Ahmad ◽  
Habib Nasir ◽  
Azhar Mahmood ◽  
Hussnain A. Janjua

The scope of optical sensors and scanners in aquatic media, fluids, and medical diagnostics has been limited by paucity of transparent shielding materials with antifouling potential. In this research endeavor, facile synthesis, characterization, and bioassay of antifouling transparent functional copolymers are reported. Copolymers of 3-sulfopropyl methacrylate (SPMA) and methyl methacrylate (MMA) were synthesized by free radical polymerization in various proportions. Samples PSM20, PSM30, PSM40, PSM50, and PSM60 contain 20%, 30%, 40%, 50%, and 60% SPMA by weight, respectively. Resultant products were characterized by FTIR and 1H-NMR spectroscopy. The synthesized copolymers have exhibited excellent transparency, i.e., 75% to 88%, as determined by the UV-Vis spectroscopic analysis. Transmittance was decreased from 6% to 2% in these copolymers upon changing the concentration of 3-sulfopropyl methacrylate from 20% to 50% owing to bacterial and algal biofilm formation. Water contact angle values were ranged from 18° to 63° and decreased with the increase in the polarity of copolymers. The surface energy lowest value 58 mJ/m2 and highest value 72 mJ/m2 were calculated for PSM20 and PSM50, respectively, by the Chibowski approach and Young equation. Sample PSM50 has exhibited the highest antibacterial activities, i.e., 18 mm and 19 mm, against Escherichia coli and Staphylococcus aureus, respectively, by the disk diffusion method. Copolymer PSM50 has shown minimum algal adhesion for Dictyosphaerium algae as observed by optical microscopy. This lower bacterial and algal adhesion is attributed to higher concentrations of anionic SPMA monomer that cause electrostatic repulsion between functional groups of the polymer and microorganisms. Thus, the resultant PSM50 product has exhibited good potential for optronics shielding application in aquatic medium and medical diagnostics.


VASA ◽  
2015 ◽  
Vol 44 (5) ◽  
pp. 355-362 ◽  
Author(s):  
Marie Urban ◽  
Alban Fouasson-Chailloux ◽  
Isabelle Signolet ◽  
Christophe Colas Ribas ◽  
Mathieu Feuilloy ◽  
...  

Abstract. Summary: Background: We aimed at estimating the agreement between the Medicap® (photo-optical) and Radiometer® (electro-chemical) sensors during exercise transcutaneous oxygen pressure (tcpO2) tests. Our hypothesis was that although absolute starting values (tcpO2rest: mean over 2 minutes) might be different, tcpO2-changes over time and the minimal value of the decrease from rest of oxygen pressure (DROPmin) results at exercise shall be concordant between the two systems. Patients and methods: Forty seven patients with arterial claudication (65 + / - 7 years) performed a treadmill test with 5 probes each of the electro-chemical and photo-optical devices simultaneously, one of each system on the chest, on each buttock and on each calf. Results: Seventeen Medicap® probes disconnected during the tests. tcpO2rest and DROPmin values were higher with Medicap® than with Radiometer®, by 13.7 + / - 17.1 mm Hg and 3.4 + / - 11.7 mm Hg, respectively. Despite the differences in absolute starting values, changes over time were similar between the two systems. The concordance between the two systems was approximately 70 % for classification of test results from DROPmin. Conclusions: Photo-optical sensors are promising alternatives to electro-chemical sensors for exercise oximetry, provided that miniaturisation and weight reduction of the new sensors are possible.


2020 ◽  
pp. 38-44
Author(s):  
A. V. Polyakov ◽  
M. A. Ksenofontov

Optical technologies for measuring electrical quantities attract great attention due to their unique properties and significant advantages over other technologies used in high-voltage electric power industry: the use of optical fibers ensures high stability of measuring equipment to electromagnetic interference and galvanic isolation of high-voltage sensors; external electromagnetic fields do not influence the data transmitted from optical sensors via fiber-optic communication lines; problems associated with ground loops are eliminated, there are no side electromagnetic radiation and crosstalk between the channels. The structure and operation principle of a quasi-distributed fiber-optic high-voltage monitoring system is presented. The sensitive element is a combination of a piezo-ceramic tube with an optical fiber wound around it. The device uses reverse transverse piezoelectric effect. The measurement principle is based on recording the change in the recirculation frequency under the applied voltage influence. When the measuring sections are arranged in ascending order of the measured effective voltages relative to the receiving-transmitting unit, a relative resolution of 0,3–0,45 % is achieved for the PZT-5H and 0,8–1,2 % for the PZT-4 in the voltage range 20–150 kV.


2004 ◽  
Vol 9 (1) ◽  
pp. 55-63
Author(s):  
V. Kleiza

Light transmission in the reflection fiber system, located in external optical media, has been investigated for application as sensors. The system was simulated by different models, including external cavity parameters such as the distance between light emitting and receiving fibers and mirror positioning distance. The sensitivity to a linear displacement of the sensors was studied as a function of the distance between the tips of the light emitting fiber and the center of the pair reflected light collecting fibers, by positioning a mirror. Physical fundamentals and operating principles of the advanced fiber optical sensors were revealed.


2000 ◽  
Vol 628 ◽  
Author(s):  
Mark A. Clarner ◽  
Michael J. Lochhead

ABSTRACTOrganically modified silica gels and dye-doped silica gels have been patterned into micrometer-scale structures on a substrate using micro molding in capillaries (MIMIC). This approach is from a class of elastomeric stamping and molding techniques collectively known as soft lithography. Soft lithography and sol-gel processing share attractive features in that they are relatively benign processes performed at ambient conditions, which makes both techniques compatible with a wide variety of organic molecules, molecular assemblies, and biomolecules. The combination of sol-gel and soft lithography, therefore, holds enormous promise as a tool for microfabrication of materials with optical, chemical, or biological functionality that are not readily patterned with conventional methods. This paper describes our investigation of micro-patterned organic-inorganic hybrid materials containing indicator dyes for microfluidic sensor applications. Reversible colorimetric pH sensing via entrapped reagents is demonstrated in a prototype microfluidic sensor element. Patterned structures range from one to tens of micrometers in cross-section and are up to centimeters in length. Fundamental chemical processing issues associated with mold filling, cracking and sensor stability are discussed.


Sign in / Sign up

Export Citation Format

Share Document