Osteoarthritis induction leads to early and temporal subchondral plate porosity in the tibial plateau of mice: An in vivo microfocal computed tomography study

2011 ◽  
Vol 63 (9) ◽  
pp. 2690-2699 ◽  
Author(s):  
Sander M. Botter ◽  
Gerjo J. V. M. van Osch ◽  
Stefan Clockaerts ◽  
Jan H. Waarsing ◽  
Harrie Weinans ◽  
...  
2020 ◽  
Author(s):  
Shatadru Chakravarty ◽  
Jeremy Hix ◽  
Kaitlyn Wieweora ◽  
Maximilian Volk ◽  
Elizabeth Kenyon ◽  
...  

Here we describe the synthesis, characterization and in vitro and in vivo performance of a series of tantalum oxide (TaOx) based nanoparticles (NPs) for computed tomography (CT). Five distinct versions of 9-12 nm diameter silane coated TaOx nanocrystals (NCs) were fabricated by a sol-gel method with varying degrees of hydrophilicity and with or without fluorescence, with the highest reported Ta content to date (78%). Highly hydrophilic NCs were left bare and were evaluated in vivo in mice for micro-CT of full body vasculature, where following intravenous injection, TaOx NCs demonstrate high CT contrast, circulation in blood for ~ 3 h, and eventual accumulation in RES organs; and following injection locally in the mammary gland, where the full ductal tree structure can be clearly delineated. Partially hydrophilic NCs were encapsulated within mesoporous silica nanoparticles (MSNPs; TaOx@MSNPs) and hydrophobic NCs were encapsulated within poly(lactic-co-glycolic acid) (PLGA; TaOx@PLGA) NPs, serving as potential CT-imagable drug delivery vehicles. Bolus intramuscular injections of TaOx@PLGA NPs and TaOx@MSNPs to mimic the accumulation of NPs at a tumor site produce high signal enhancement in mice. In vitro studies on bare NCs and formuated NPs demonstrate high cytocompatibility and low dissolution of TaOx. This work solidifies that TaOx-based NPs are versatile contrast agents for CT.


2020 ◽  
Vol 26 (18) ◽  
pp. 2167-2181
Author(s):  
Tatielle do Nascimento ◽  
Melanie Tavares ◽  
Mariana S.S.B. Monteiro ◽  
Ralph Santos-Oliveira ◽  
Adriane R. Todeschini ◽  
...  

Background: Cancer is a set of diseases formed by abnormal growth of cells leading to the formation of the tumor. The diagnosis can be made through symptoms’ evaluation or imaging tests, however, the techniques are limited and the tumor detection may be late. Thus, pharmaceutical nanotechnology has emerged to optimize the cancer diagnosis through nanostructured contrast agent’s development. Objective: This review aims to identify commercialized nanomedicines and patents for cancer diagnosis. Methods: The databases used for scientific articles research were Pubmed, Science Direct, Scielo and Lilacs. Research on companies’ websites and articles for the recognition of commercial nanomedicines was performed. The Derwent tool was applied for patent research. Results: This article aimed to research on nanosystems based on nanoparticles, dendrimers, liposomes, composites and quantum dots, associated to imaging techniques. Commercialized products based on metal and composite nanoparticles, associated with magnetic resonance and computed tomography, have been observed. The research conducted through Derwent tool displayed a small number of patents using nanotechnology for cancer diagnosis. Among these patents, the most significant number was related to the use of systems based on metal nanoparticles, composites and quantum dots. Conclusion: Although few systems are found in the market and patented, nanotechnology appears as a promising field for the development of new nanosystems in order to optimize and accelerate the cancer diagnosis.


2015 ◽  
Vol 5 (1) ◽  
Author(s):  
Philipp S. Lienemann ◽  
Stéphanie Metzger ◽  
Anna-Sofia Kiveliö ◽  
Alain Blanc ◽  
Panagiota Papageorgiou ◽  
...  

Abstract Over the last decades, great strides were made in the development of novel implants for the treatment of bone defects. The increasing versatility and complexity of these implant designs request for concurrent advances in means to assess in vivo the course of induced bone formation in preclinical models. Since its discovery, micro-computed tomography (micro-CT) has excelled as powerful high-resolution technique for non-invasive assessment of newly formed bone tissue. However, micro-CT fails to provide spatiotemporal information on biological processes ongoing during bone regeneration. Conversely, due to the versatile applicability and cost-effectiveness, single photon emission computed tomography (SPECT) would be an ideal technique for assessing such biological processes with high sensitivity and for nuclear imaging comparably high resolution (<1 mm). Herein, we employ modular designed poly(ethylene glycol)-based hydrogels that release bone morphogenetic protein to guide the healing of critical sized calvarial bone defects. By combined in vivo longitudinal multi-pinhole SPECT and micro-CT evaluations we determine the spatiotemporal course of bone formation and remodeling within this synthetic hydrogel implant. End point evaluations by high resolution micro-CT and histological evaluation confirm the value of this approach to follow and optimize bone-inducing biomaterials.


Biomaterials ◽  
2012 ◽  
Vol 33 (36) ◽  
pp. 9232-9238 ◽  
Author(s):  
Songjun Zeng ◽  
Ming-Kiu Tsang ◽  
Chi-Fai Chan ◽  
Ka-Leung Wong ◽  
Jianhua Hao

2010 ◽  
Vol 24 (1) ◽  
pp. 127-139 ◽  
Author(s):  
Jean-Dominique Singland ◽  
David Mitton ◽  
Anne Guillaume ◽  
Philippe Cluzel ◽  
Pascal Goasdoue ◽  
...  

2017 ◽  
Author(s):  
Joshua P Klein

Modern neuroimaging has revolutionized the practice of neurology by allowing visualization and monitoring of evolving pathophysiologic processes. High-resolution magnetic resonance imaging (MRI) can now resolve structural abnormalities on a near-cellular level. Advances in functional imaging can assess the in vivo metabolic, vascular, and functional states of neuronal and glial populations in real time. Given the high density of data obtained from neuroimaging studies, it is essential for the clinician to take an active role in understanding the nature and significance of imaging abnormalities. This chapter reviews computed tomography and MRI techniques (including angiography and advanced sequences), specialized protocols for investigating specific diagnoses, risks associated with imaging, disease-specific imaging findings with general strategies for interpretation, and incidental findings and artifacts. Figures include computed tomography, T1- and T2-weighted signal intensity, diffusion-weighted magnetic resonance imaging, magnetic resonance spectroscopy, imaging in epilepsy and dementia, extra-axial versus intra-axial lesions, typical lesions of multiple sclerosis, spinal imaging, spinal pathology, vascular pathology, intracranial hemorrhage, and common imaging artifacts. Tables list Hounsfield units, patterns of enhancement from imaging, advanced techniques in imaging, magnetic resonance imaging sequences, and the evolution of cerebral infarction and intraparenchymal hemorrhage on magnetic resonance imaging. This review contains 12 figures, 6 tables, and 213 references.


2009 ◽  
Vol 107 (5) ◽  
pp. 1569-1578 ◽  
Author(s):  
Cuneyt Yilmaz ◽  
Priya Ravikumar ◽  
D. Merrill Dane ◽  
Dennis J. Bellotto ◽  
Robert L. Johnson ◽  
...  

To quantify the in vivo magnitude and distribution of regional compensatory lung growth following extensive lung resection, we performed high-resolution computed tomography at 15- and 30-cmH2O transpulmonary pressures and measured air and tissue (including microvascular blood) volumes within and among lobes in six adult male foxhounds, before and after balanced 65% lung resection (∼32% removed from each side). Each lobe was identified from lobar fissures. Intralobar gradients in air and tissue volumes were expressed along standardized x, y, z-coordinate axes. Fractional tissue volume (FTV) was calculated as the volume ratio of tissue/(tissue + air). Following resection compared with before, lobar air and tissue volumes increased 1.8- to 3.5-fold, and whole lung air and tissue volumes were 67 and 90% of normal, respectively. Lobar-specific compliance doubled post-resection, and whole lung-specific compliance normalized. These results are consistent with vigorous compensatory growth in all remaining lobes. Compared with pre-resection, post-resection interlobar heterogeneity of FTV, assessed from the coefficient of variation, decreased at submaximal inflation, but was unchanged at maximal inflation. The coefficient of variation of intralobar FTV gradients changed variably due to the patchy development of thickened pleura and alveolar septa, with elevated alveolar septal density and connective tissue content in posterior-caudal and peripheral regions of the remaining lobes; these areas likely experienced disproportional mechanical stress. We conclude that HRCT can noninvasively and quantitatively assess the magnitude and spatial distribution of compensatory lung growth. Following extensive resection, heterogeneous regional mechanical lung strain may exceed the level that could be sustained solely by existing connective tissue elements.


Sign in / Sign up

Export Citation Format

Share Document