In vitro electrical impedance spectroscopy of human dentine: The effect of restorative materials

2008 ◽  
Vol 29 (3) ◽  
pp. 163-168 ◽  
Author(s):  
Berta Rivas ◽  
Pablo M. Botta ◽  
Purificación Varela ◽  
Benjamín Martín ◽  
Alfonso Fondado ◽  
...  
2018 ◽  
Vol 18 (6) ◽  
pp. 854-864 ◽  
Author(s):  
Mustapha M. Bouhenna ◽  
Nabil Mameri ◽  
Mónica V. Pérez ◽  
Oualid Talhi ◽  
Khaldoun Bachari ◽  
...  

Aims: Oncology treatments aim at selective toxicity for tumor (compared to normal) cells, and chromone- coumarin hybrids have shown such activity. Methods: In this study, we test a novel series of synthetic chromone and coumarin derivatives (1–9) for cytotoxic activity against a panel of tumor cell lines (MCF-7, A549, HepG2, HTC-116, B16 and Caco-2) opposed to non-tumor cells (HEK-293t). Electrical impedance spectroscopy was used to monitor cell viability in real time. Results: Compound 8 showed the most potent activity, and it significantly diminished cancer cell proliferation and viability in different cell lines. It induced apoptosis in a dose-dependent manner, as shown by Western blot and flow cytometry. Conclusion: Electrical impedance spectroscopy appears to be a convenient tool for in vitro cytotoxicity analysis, which could be useful for identifying drug effects and side effects during early phases of drug discovery and development.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1433
Author(s):  
Esther Tanumihardja ◽  
Douwe S. de Bruijn ◽  
Rolf H. Slaats ◽  
Wouter Olthuis ◽  
Albert van den Berg

A ruthenium oxide (RuOx) electrode was used to monitor contractile events of human pluripotent stem cells-derived cardiomyocytes (hPSC-CMs) through electrical impedance spectroscopy (EIS). Using RuOx electrodes presents an advantage over standard thin film Pt electrodes because the RuOx electrodes can also be used as electrochemical sensor for pH, O2, and nitric oxide, providing multisensory functionality with the same electrode. First, the EIS signal was validated in an optically transparent well-plate setup using Pt wire electrodes. This way, visual data could be recorded simultaneously. Frequency analyses of both EIS and the visual data revealed almost identical frequency components. This suggests both the EIS and visual data captured the similar events of the beating of (an area of) hPSC-CMs. Similar EIS measurement was then performed using the RuOx electrode, which yielded comparable signal and periodicity. This mode of operation adds to the versatility of the RuOx electrode’s use in in vitro studies.


2021 ◽  
Vol 232 (2) ◽  
Author(s):  
Rakibul Islam Chowdhury ◽  
Rinku Basak ◽  
Khan Arif Wahid ◽  
Katy Nugent ◽  
Helen Baulch

2020 ◽  
Vol 28 ◽  
pp. 1679-1685
Author(s):  
Angeliki-Eirini Dimou ◽  
Ioanna Sakellariou ◽  
George M. Maistros ◽  
Nikolaos D. Alexopoulos

Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 1001
Author(s):  
Sooin Huh ◽  
Hye-Jin Kim ◽  
Seungah Lee ◽  
Jinwoo Cho ◽  
Aera Jang ◽  
...  

This study presents a system for assessing the freshness of meat with electrical impedance spectroscopy (EIS) in the frequency range of 125 Hz to 128 kHz combined with an image classifier for non-destructive and low-cost applications. The freshness standard is established by measuring the aerobic plate count (APC), 2-thiobarbituric acid reactive substances (TBARS), and composition analysis (crude fat, crude protein, and moisture) values of the microbiological detection to represent the correlation between EIS and meat freshness. The EIS and images of meat are combined to predict the freshness with the Adaboost classification and gradient boosting regression algorithms. As a result, when the elapsed time of beef storage for 48 h is classified into three classes, the time prediction accuracy is up to 85% compared to prediction accuracy of 56.7% when only images are used without EIS information. Significantly, the relative standard deviation (RSD) of APC and TBARS value predictions with EIS and images datum achieves 0.890 and 0.678, respectively.


Allergy ◽  
2021 ◽  
Author(s):  
Arturo O. Rinaldi ◽  
Angelica Korsfeldt ◽  
Siobhan Ward ◽  
Daniel Burla ◽  
Anita Dreher ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document