Wireless and Portable System for the Study of in-vitro Cell Culture Impedance Spectrum by Electrical Impedance Spectroscopy

Author(s):  
E. De Roux ◽  
M. Terosiet ◽  
F. Kolbl ◽  
J. Chrun ◽  
P.H. Aubert ◽  
...  
2002 ◽  
Vol 12 (1) ◽  
pp. 17-29 ◽  
Author(s):  
T. Repo ◽  
D.H. Paine ◽  
A.G. Taylor

A method, electrical impedance spectroscopy (EIS), is introduced to study seed viability non-destructively. Snap bean (Phaseolus vulgaris L.) seeds were studied by EIS to determine the most sensitive EIS parameter(s) and the optimal range of moisture content (MC) for separation of viable and non-viable seeds. Hydrated seeds exhibited two impedance arcs in the complex plane at the frequency range from 60 Hz to 8 MHz, and impedance spectra of viable and non-viable seeds differed. The hydrated seeds were best-modelled by an equivalent electrical circuit with two distributed circuit elements in series with a resistor (Voigt model). Moisture content and seed viability had strong effects on the EIS parameters. The most sensitive EIS parameters for detecting the differences between viable and non-viable seeds were the capacitance log(C2), the resistance R2, the resistance ratio R2/R1 and the apex ratio, which all represent specific features of the impedance spectrum. The highest differentiation in the EIS parameters between the viable and non-viable seeds occurred in partially imbibed seeds between MC of 40 and 45% (fresh weight basis).


2021 ◽  
Author(s):  
Binying Yang ◽  
Jia Xu ◽  
Shao Hu ◽  
Boning You ◽  
Qing Ma

Abstract Background: Lead is a nonessential heavy metal, which can inhibit heme synthesis and has significant cytotoxic effects. Nevertheless, its effect on the electrical properties of red blood cells (RBCs) remains unclear. Consequently, this study aimed to investigate the electrical properties and the electrophysiological mechanism of lead exposure in mouse blood using Electrical Impedance Spectroscopy (EIS). Methods: AC impedance method was used to measure the electrical impedance of healthy and lead exposure blood of mice in 0.01-100 MHz frequency range. Data characteristic of the impedance spectrum, Bodes plot, Nyquist plot and Nichols plot, and three elements equivalent circuit model were used to explicitly analyze the differences in amplitude-frequency, phase-frequency, and the frequency characteristic of blood in electrical impedance properties. Results: Compared with the healthy blood in control mice, the changes in blood exposed to lead was as follows: (I) the hematocrit decreased; (II) the amplitude-frequency and phase-frequency characteristics of electrical impedance decreased; (III) the characteristic frequencies ( f 0 ) were significantly increased; (IV) the electrical impedance of plasma, erythrocyte membrane, and hemoglobin decreased, while the conductivity increased. Conclusion: Therefore, EIS can be used as an effective method to monitor blood and RBCs abnormalities caused by lead-exposure.


2008 ◽  
Vol 29 (3) ◽  
pp. 163-168 ◽  
Author(s):  
Berta Rivas ◽  
Pablo M. Botta ◽  
Purificación Varela ◽  
Benjamín Martín ◽  
Alfonso Fondado ◽  
...  

2018 ◽  
Vol 18 (6) ◽  
pp. 854-864 ◽  
Author(s):  
Mustapha M. Bouhenna ◽  
Nabil Mameri ◽  
Mónica V. Pérez ◽  
Oualid Talhi ◽  
Khaldoun Bachari ◽  
...  

Aims: Oncology treatments aim at selective toxicity for tumor (compared to normal) cells, and chromone- coumarin hybrids have shown such activity. Methods: In this study, we test a novel series of synthetic chromone and coumarin derivatives (1–9) for cytotoxic activity against a panel of tumor cell lines (MCF-7, A549, HepG2, HTC-116, B16 and Caco-2) opposed to non-tumor cells (HEK-293t). Electrical impedance spectroscopy was used to monitor cell viability in real time. Results: Compound 8 showed the most potent activity, and it significantly diminished cancer cell proliferation and viability in different cell lines. It induced apoptosis in a dose-dependent manner, as shown by Western blot and flow cytometry. Conclusion: Electrical impedance spectroscopy appears to be a convenient tool for in vitro cytotoxicity analysis, which could be useful for identifying drug effects and side effects during early phases of drug discovery and development.


Author(s):  
Shenggen Hu ◽  
Bruce Firth

In this research work, an electrical impedance spectroscopy technique has been developed to measure the solids concentration of slurry mixtures. This new measurement technique is based on the fact that the AC frequency responses of solids are distinct from those for the liquid phase. In this technique, the electrical impedance spectrum of slurry mixtures is measured over the frequency range of 0.1 Hz to 1 MHz. Changes in the frequency response at different excitation signal amplitudes reflect changes in the slurry composition and the electrical conductivity of the liquid phase, and by analyzing the spectra using artificial intelligence data analysis techniques, such as Multiplayer Perceptron Artificial Neural Network, one can determine the volumetric fraction of the solids phase. The technique has been successfully tested for various slurries under different conductivities of liquid phase and temperatures. In contrast with previous techniques based on conductivity or capacitance, this new technique can be used for on-line measurement of solids concentration in slurry streams even when the conductivity of the liquid phase changes substantially with time.


2020 ◽  
Vol 6 (3) ◽  
pp. 341-344
Author(s):  
Viviane S. Teixeira ◽  
Vera Labitzky ◽  
Udo Schumacher ◽  
Wolfgang Krautschneider

AbstractCancer and normal tissues are visually different from each other, especially so in more advanced cancer stages. More important, they are not only visually contrasting, but if an electric field is applied to both tissue types and the frequency is varied in a wide range, it will be seen that the two tissue types in general have a spectral response divergent from each other and this has to do with the characteristics of cancer tissues in contrast to normal ones. In this work, Electrical Impedance Spectroscopy is applied to try to distinguish cancer from healthy tissues by means of their impedance spectrum using a four-electrode-terminal setup. The use of the fourterminal- setup setup is important to circumvent the impact of electrode polarization at frequencies below 1 kHz.


2021 ◽  
Vol 20 (1) ◽  
Author(s):  
Binying Yang ◽  
Jia Xu ◽  
Shao Hu ◽  
Boning You ◽  
Qing Ma

Abstract Background Lead is a nonessential heavy metal, which can inhibit heme synthesis and has significant cytotoxic effects. Nevertheless, its effect on the electrical properties of red blood cells (RBCs) remains unclear. Consequently, this study aimed to investigate the electrical properties and the electrophysiological mechanism of lead exposure in mouse blood using Electrical Impedance Spectroscopy (EIS) in 0.01–100 MHz frequency range. Data characteristic of the impedance spectrum, Bodes plot, Nyquist plot and Nichols plot, and Constant Phase Element (CPE) equivalent circuit model were used to explicitly analyze the differences in amplitude–frequency, phase–frequency, and the frequency characteristics of blood in electrical impedance properties. Results Compared with the healthy blood in control mice, the changes in blood exposed to lead were as follows: (i) the hematocrit decreased; (ii) the amplitude–frequency and phase–frequency characteristics of electrical impedance decreased; (iii) the characteristic frequencies (f0) were significantly increased; (iv) the electrical impedance of plasma, erythrocyte membrane, and hemoglobin decreased, while the conductivity increased. (v) The pseudo-capacitance of cell membrane (CPE_Tm) and the intracellular pseudo-capacitance (CPE-Ti) were decreased. Conclusions Therefore, EIS can be used as an effective method to monitor blood and RBC abnormalities caused by lead exposure. The electrical properties of the cells can be applied as an important observation in the evaluation of the toxic effects of heavy metals.


Sign in / Sign up

Export Citation Format

Share Document