Energy-saving evaluation of a thermosyphon heat recovery unit for an air-conditioning system

2013 ◽  
Vol 42 (5) ◽  
pp. 377-388 ◽  
Author(s):  
Guoyuan Ma ◽  
Feng Zhou ◽  
Ting Liu ◽  
Liangbing Wang ◽  
Zhongliang Liu
2017 ◽  
Vol 865 ◽  
pp. 212-216
Author(s):  
Xiang Dong Wu ◽  
Ze Hua Liu

Combining with the energy consumption of air-conditioning system and the characteristics of the cooling and heating load in the hotel, the authors analyse the energy-saving property and necessity of adopting condensing heat recovery from water chillers. Taking the air-conditioning system of a star-hotel as an example, the optimization design for condensing heat recovery system from chillers on raising the temperature difference between supply and return water, the hot-water tanks in series and the water temperature stratification effectively realizes cascade and sequential utilization of hot-water, which keeps the water temperature stable and becomes more energy-saving.


2007 ◽  
Vol 2 (3) ◽  
pp. 86-95
Author(s):  
R. Sudhakaran ◽  
◽  
V. Sella Durai ◽  
T. Kannan ◽  
P.S. Sivasakthievel ◽  
...  

Symmetry ◽  
2021 ◽  
Vol 13 (2) ◽  
pp. 344
Author(s):  
Alejandro Humberto García Ruiz ◽  
Salvador Ibarra Martínez ◽  
José Antonio Castán Rocha ◽  
Jesús David Terán Villanueva ◽  
Julio Laria Menchaca ◽  
...  

Electricity is one of the most important resources for the growth and sustainability of the population. This paper assesses the energy consumption and user satisfaction of a simulated air conditioning system controlled with two different optimization algorithms. The algorithms are a genetic algorithm (GA), implemented from the state of the art, and a non-dominated sorting genetic algorithm II (NSGA II) proposed in this paper; these algorithms control an air conditioning system considering user preferences. It is worth noting that we made several modifications to the objective function’s definition to make it more robust. The energy-saving optimization is essential to reduce CO2 emissions and economic costs; on the other hand, it is desirable for the user to feel comfortable, yet it will entail a higher energy consumption. Thus, we integrate user preferences with energy-saving on a single weighted function and a Pareto bi-objective problem to increase user satisfaction and decrease electrical energy consumption. To assess the experimentation, we constructed a simulator by training a backpropagation neural network with real data from a laboratory’s air conditioning system. According to the results, we conclude that NSGA II provides better results than the state of the art (GA) regarding user preferences and energy-saving.


2018 ◽  
Vol 38 ◽  
pp. 04012
Author(s):  
Sai Feng Xu ◽  
Xing Lin Yang ◽  
Zou Ying Le

For ocean-going vessels sailing in different areas on the sea, the change of external environment factors will cause frequent changes in load, traditional ship air-conditioning system is usually designed with a fixed cooling capacity, this design method causes serious waste of resources. A new type of sea-based air conditioning system is proposed in this paper, which uses the sea-based source heat pump system, combined with variable air volume, variable water technology. The multifunctional cabins’ dynamic loads for a ship navigating in a typical Eurasian route were calculated based on Simulink. The model can predict changes in full voyage load. Based on the simulation model, the effects of variable air volume and variable water volume on the energy consumption of the air-conditioning system are analyzed. The results show that: When the VAV is coupled with the VWV, the energy saving rate is 23.2%. Therefore, the application of variable air volume and variable water technology to marine air conditioning systems can achieve economical and energy saving advantages.


Author(s):  
Mostafa El-Shafie ◽  
M. Khalil Bassiouny ◽  
Shinji Kambara ◽  
Samy M. El-Behery ◽  
A.A. Hussien

2019 ◽  
Vol 17 (1) ◽  
pp. 88
Author(s):  
Herman Nawir ◽  
Kusmanurwira Kusmanurwira ◽  
Alif Firdaus

Abstract In the hotel business, the use of energy is very important, especially in the use of electricity, the portion of usage and allocation of funds for its provision is the largest. It can be seen that equipment such as lights, elevators, refrigerators, laundry, heaters, pumps, to the air conditioning system are some of the dominant tools in operations in the hospitality world. The results of the initial energy audit and detailed audit at the Grand Clarion Hotel Makassar showed that the Energy Consumption Intensity (IKE) is still far from the standard, which is 300 kWh / m2 a year. The building uses the largest amount of electricity in the Grand Clarion Hotel Makassar in Building A, which is in the Guest Room area of the air conditioning unit. The results of the initial energy audit of Energy Consumption Intensity (IKE) electricity were 336.84 kWh / m2 year. Whereas based on the results of a detailed energy audit the electricity consumption intensity (IKE) of electricity is 395.51 kWh / m2 a year. Energy Saving Opportunities (PHE) in this energy audit is to evaluate the AC power in each room and recommend the replacement of lamp types. From the results of the IKE calculation after the application of PHE, it is found that the value is still quite high so that efforts to save must still be done. 


2012 ◽  
Vol 516-517 ◽  
pp. 1224-1228
Author(s):  
Na Liang ◽  
Rui Li

Due to energy reserves reduces gradually and uneven distribution, all countries pay more and more attention to energy saving and improve the effective utilization of energy, China also attaches great important to this. Energy saving of buildings is a necessary development trend. Air conditioning system as a large important part of building energy consumption has a huge energy-saving potential. This article mainly introduced the related strategies of energy saving in central air conditioning water system from the following three points of view: the water treatment, the cooling tower, and the variable frequency pump.