Single-incision laparoscopic abdominal cerclage placement: A retrospective study of single-port and robotic single-port versus multiport laparoscopy

2018 ◽  
Vol 142 (2) ◽  
pp. 236-238
Author(s):  
Yiming Zhang ◽  
Manisha Gandhi ◽  
Courtney Birchall ◽  
Xiaoming Guan
HPB Surgery ◽  
2011 ◽  
Vol 2011 ◽  
pp. 1-3 ◽  
Author(s):  
Kamil Gulpinar ◽  
Suleyman Ozdemir ◽  
S. Erpulat Ozis ◽  
Turgut Aydin ◽  
Atila Korkmaz

Purpose. We present our experience in single incision laparoscopic cholecystectomy by using a grasper directly without using a trocar in five patients. Methods and Results. The technique involves the use of Karl Storz 27290F grasper in order to perform gallbladder retraction in single port cholecystectomy. The grasper was introduced directly into the skin through abdominal wall without using any trocar and used to mobilize gallbladder whenever needed during surgery without causing any perforation or leakage of the gallbladder. There were no intraoperative and postoperative complications in 5 patients with the advantages of shorter operation time and almost invisible postoperative skin scar formation. Conclusion. We claim that the use of this instrument in SILS surgery might be advantageous than the conventional placement of sutures for the gallbladder mobilization.


Animals ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 1242
Author(s):  
Georg Haider ◽  
Ursula Schulz ◽  
Nikola Katic ◽  
Christian Peham ◽  
Gilles Dupré

Single-port access systems (SPASs) are currently used in human and veterinary surgeries. However, they pose technical challenges, such as instrument crowding, intra- and extracorporeal instrument collision, and reduced maneuverability. Studies comparing the maneuverability of the scopes and instruments in different SPASs are lacking. This study aimed to compare the maneuverability of three different SPASs: the Covidien SILS-port, Storz Endocone, and glove port. A clear acrylic box with artificial skin placed at the bottom was used to mimic the abdominal wall and cavity. The three SPASs were placed from below, and a 10-mm endoscope and 5-mm instrument were introduced. A motion analysis system consisting of 18 cameras and motion analysis software were used to track the movement of the endoscope and instrument, to determine the volume of the cone-shaped, three-dimensional figures over which movement was possible, with higher values indicating greater maneuverability. The Mann–Whitney U test was used for the analysis. The maneuverability of the endoscope alone was significantly higher in the glove port system than in the other two SPASs. When inserting an additional instrument, the maneuverability significantly decreased in the SILS-port and Endocone, but not in the glove port. The highest maneuverability overall was found in the glove port.


2021 ◽  
Author(s):  
M. Luann Racher ◽  
Ann Marie Mercier

Single incision laparoscopic surgery encompasses a plethora of techniques and styles. Single incision laparoscopy has demonstrated outcomes comparable to traditional multiport laparoscopy with the added benefit of improved cosmesis. This book chapter will review single incision surgery for minor gynecologic surgery, including adnexal surgical procedures and myomectomy. The chapter reviews available data in regard to outcomes in single incision laparoscopy. It also discusses the commercially available single incision surgical access systems, laparoscopes, and accessory instruments. Surgical techniques beneficial in single incision laparosocpy, including uterine manipulation, are also reviewed.


2016 ◽  
Vol 5 (3) ◽  
pp. e165 ◽  
Author(s):  
Rene Mantke ◽  
Markus Diener ◽  
Siegfried Kropf ◽  
Ronny Otto ◽  
Thomas Manger ◽  
...  

2022 ◽  
Vol 11 ◽  
Author(s):  
Changgang Wang ◽  
Haoran Feng ◽  
Xiaoning Zhu ◽  
Zijia Song ◽  
You Li ◽  
...  

BackgroundRecently, enhanced recovery after surgery (ERAS) has been widely used in the perioperative management of colorectal cancer (CRC). This study aimed to evaluate the safety and feasibility of ERAS combined with single-incision laparoscopic surgery (SILS) in CRC surgery.MethodsThis was a retrospective study of patients with CRC who underwent surgery between April 2018 and April 2020 in Ruijin Hospital(North), Shanghai Jiaotong University School of Medicine. The patients were divided into three groups: group A (n=138), patients who underwent traditional multiport laparoscopic colectomy with conventional perioperative management; group B (n=63), patients who underwent SILS; and group C (n=51), patients who underwent SILS with ERAS.ResultsOverall, 252 participants were included in the retrospective study. The median operation time (min) in group B and group C was shorter than that in group A (group A 134.0 ± 42.5; group B 117 ± 38.9; group C 111.7 ± 35.4, p=0.004). The estimated surgical blood loss (ml) was lower in groups B and C than in group A (group A 165.1 ± 142.2; group B 122.0 ± 79.4; group C 105.2 ± 55.8, p=0.011). The length of surgical incision (cm) was shorter in groups B and C than in group A (group A 7.34 ± 1.05; group B 5.60 ± 0.80; group C 5.28 ± 0.52, p<0.001). The time before first flatus (hours) in group C was shorter than in groups A and B (group A 61.85 ± 21.14; group B 58.30 ± 20.08; group C 42.06 ± 23.72; p<0.001). The days prior to the administration of free oral fluids in group C was shorter than in groups A and B (group A 4.79 ± 1.28; group B 4.67 ± 1.11; group C 2.62 ± 0.64; p<0.001). The days of prior solid diet was less in group C than in groups A and B (group A 7.22 ± 3.87; group B 7.08 ± 3.18; group C 5.75 ± 1.70; p=0.027). The postoperative length of stay (LOS) was less in group C compared with that in groups A and B (group A 9.46 ± 4.84 days; group B 9.52 ± 7.45 days; group C 7.20 ± 2.37 days; p=0.023). The visual analog scale (VAS) scores on day 0, 1, and 2 in groups B and C were lower than those in group A (day 0, p<0.001; day 1, p<0.001; day 2, p=0.002), while the VAS score on day 3 showed no differences in the three groups (group A 1.29 ± 1.38; group B 0.98 ± 1.24; group C 0.75 ± 0.64, p=0.018).ConclusionThe findings suggest that SILS combined with ERAS may be a feasible and safe procedure for CRC surgery because it provides favorable cosmetic results, early dietary resumption, shorter hospital stays, and appropriate control of postoperative pain without increases in complications or readmission rates compared to conventional perioperative care with SILS or conventional laparoscopic surgery(CLS) of CRC. Further prospective randomized controlled studies are needed to enhance evidence-based medical evidence.


2019 ◽  
Author(s):  
Xiaojun Wang ◽  
Haibo Jin ◽  
YongFeng Shuai ◽  
YiZhong Zhang

Abstract Background To discuss the reliability and clinical value of Iconport, a Self-made single port device, which was applied for transumbilical single port laparoscopic appendectomy. Methods The incision was around 2.5 cm long with curved form around umbilicus. And the skin and each layer of the abdominal wall were cut in sequence. Then the silica gel sleeve of the self-made single-incision sealing device was folded, clamped by the forceps, and carefully inserted into the incision for sealing. The operation of laparoscopic appendectomy was accomplished by-use routine linetype laparoscopic instruments via Iconport. The specimen was discharged from peritoneal cavity through the single port device. Two layers of incision, linea alba abdominus and skin, were separately sutured by absorbable thread and each layer was sutured successively. Results Among the 125 patients, 119 were successfully performed single-port laparoscopic appendectomy, with the operation time ranging from 30 to 110 min (69.34±21.4 min on average). In 6 cases, auxiliary operating hole was added or laparotomy was performed. Total hospital stay was 5.0±1.8 (2-14) days. 5 cases of incision infection. All patients were followed up for 1 to 6 months after surgery, with an average of 3 months. There were no complications such as bleeding, intestinal leakage, intestinal obstruction, and residual peritoneal effusion. Conclusion In single-incision laparoscopic surgery, the u-shaped incision around the umbilical margin of 2.5cm for adult can not only meet the requirements of flexibility of instruments in the operation, but also meet the aesthetic requirements because the incision scar is hidden in the umbilical foramen or looks like the umbilical foramen after the operation. Iconport single-hole device, which has potential promotion value, can be used in relatively simple laparoscopic surgery alone or combined with a single puncture device for relatively complex laparoscopic surgery.


Sign in / Sign up

Export Citation Format

Share Document