Separation Results

Keyword(s):  
2011 ◽  
Vol 6 (12) ◽  
pp. 2112-2119 ◽  
Author(s):  
Randeep Sangha ◽  
Angela M. Davies ◽  
Primo N. Lara ◽  
Philip C. Mack ◽  
Laurel A. Beckett ◽  
...  
Keyword(s):  
Phase I ◽  

2016 ◽  
Vol 3 (01) ◽  
pp. 10 ◽  
Author(s):  
Jarot Purnomo ◽  
Sorja Koesuma ◽  
Mohtar Yunianto

<span>It has been done a research about separation of regional-residual anomaly in Gravity method. <span>This research compares the result of three methods i.e. moving average method, polynomial <span>method, and inversion method. The computer program is created using a computer programming <span>Matlab 7. From three methods that have been made, the separation results are compared with<br /><span>results of separation by using Upward Continuation method. From the results of these <span>comparisons will be available an excellent program of regional-residual anomali separation. The <span>results show that in polynomial method of the order 4 obtained similar contour to the separation <span>by Upward Continuation Software. So that the output of this separation will be treated again <span>with Grav2DC software. The output of this software is the density of rock Grav2DC of the study<br /><span>area. Processing results obtained the minimum error of 1.85% for the separation by polynomial <span>method, while for the method of Upward Continuation obtained minimum error of 2.22%. The <span>results obtained show that the separation of regional-residual anomali by polynomial method is <span>similar to separation by Upward Continuation method.</span></span></span></span></span></span></span></span></span></span></span></span><br /></span>


2021 ◽  
Vol 22 (1) ◽  
pp. 127-138
Author(s):  
Dilfuza Nuriddinova

In the research work, the adsorption equilibrium, kinetics, thermodynamics and dynamic separation of magnesium and calcium ions from industrial wastewater by new strong acid cation resin of SPVC (sulphonated polyvinylchloride) were investigated. The sorption capacity of the studied resin was 3.78 mmol/g and 3.74 mmol/g for magnesium and calcium ions, respectively, according to Langmuir isotherm. It was found that the pseudo−first−order model was better fitted for the adsorption kinetics of magnesium and calcium ions on the resin. The dynamic separation results confirmed that the selected resin effectively separated magnesium and calcium ions from industrial wastewater in the dynamic condition. The change of the standard Gibbs free energy (G) and enthalpy (H), and entropy (S) were calculated. The obtained results confirmed that the adsorption of magnesium and calcium ions on the selected resin is endothermic.


2021 ◽  
Vol 42 (3(SI)) ◽  
pp. 887-894
Author(s):  
M. Sarower-E-Mahfuj ◽  
◽  
S.K. Das ◽  
K.N. Azad ◽  
A.K. Paul ◽  
...  

Aim: Landmark-based truss network system was applied to examine the morphometric and meristic differences among four different populaces of Macrognathus aculeatus namely; Dhakuriabeel, Jashore (DBJ); Arial Kha River, Madaripur (AKRM); Nabaganga River, Jhenaidah (NRJ); Kopotakkha River, Jashore (KRJ) in Bangladesh. Methodology: Completely 80 samples of M. aculeatus were collected (20 individuals from each population) for this study. Six meristic characters, 6 morphometric characters and 15 truss-based morphometric characters were measured for one-way analysis of variance (ANOVA) and Tukey-HSD post hoc test. Discriminant function analyses were also performed by using morphometric and truss-based morphometric characters to detect potential characters responsible for population separation. Results: Completely 80 samples of M. aculeatus were collected (20 individuals from each population) for this study. Six meristic characters, 6 morphometric characters and 15 truss-based morphometric characters were measured for one-way analysis of variance (ANOVA) and Tukey-HSD post hoc test. Discriminant function analyses were also performed by using morphometric and truss-based morphometric characters to detect potential characters responsible for population separation. Interpretation: The baseline information derived from the present study would be useful for appropriate conservation of M. aculeatus populations as well as for the researchers for further investigation.


1998 ◽  
Vol 41 (4) ◽  
pp. 473-477 ◽  
Author(s):  
Jürgen Müller ◽  
Jochen Wengenroth

AbstractWe present a short proof for a classical result on separating singularities of holomorphic functions. The proof is based on the open mapping theorem and the fusion lemma of Roth, which is a basic tool in complex approximation theory. The same method yields similar separation results for other classes of functions.


2020 ◽  
Vol 10 (4) ◽  
pp. 1471 ◽  
Author(s):  
Santiago Cano ◽  
Ali Gooneie ◽  
Christian Kukla ◽  
Gisbert Rieß ◽  
Clemens Holzer ◽  
...  

The adhesion of the polymer to ceramic nanoparticles is a key aspect in the manufacturing of ceramic parts by additive manufacturing and injection molding, due to poor separation results in separation during processing. The purpose of this research is to investigate, by means of molecular dynamics simulations and experimental methods, the role of improved interfacial interactions by acrylic acid grafting-high density polyethylene on the adhesion to zirconia nanoparticles and on the composite properties. The polymer grafting results in high adhesion to the nanoparticles, increases the nanoparticles dispersion and improves the viscoelastic and mechanical properties required for additive manufacturing and injection molding.


Minerals ◽  
2019 ◽  
Vol 9 (4) ◽  
pp. 215 ◽  
Author(s):  
Chen ◽  
Wang ◽  
Luo ◽  
Zhao ◽  
Lv ◽  
...  

Although compound dry separation technology has been applied to industrial applications for +6 mm size fraction of coal separation, the technology has not been widely applied in the separation of fine coal (−6 mm). In this study, the effect of the partition plate unit characteristics on both the average density of particles in the bed uniformly and the final separation results in a fine coal separation process were studied. According to the results, the standard deviations of the corresponding density distribution were 0.08, 0.14, and 0.07 when the height of the partition plate was 2.5 cm, the partition plate angle was 35°, and the distance from the apex of partition plate on the backplane, was 12 cm, respectively, which were the lowest values at the same level. These results showed that the average density of particles in the bed was uniformly, and its corresponding density distribution contour map was more regular. When the amplitude was 2.8 mm, the frequency was 29 Hz, the height of the partition plate was 2.5 cm, the partition plate angle was 35°, and the distance from the apex of the partition plate to the backplane was 12 cm; as a result, the E value was 0.115 g/cm3, the yield of the concentrate was 69.24%, the ash content was 12.52%, and the separation effect was better. The characteristics of the partition plate unit have an important effect on the separating process of −6 mm fine coal in the compound dry separator.


Sign in / Sign up

Export Citation Format

Share Document