Measurement of Fluid Thermal Conductivity with a Steady State Hot Wire Method

1994 ◽  
pp. 933-935
Author(s):  
Yasuhiko Shiinoki ◽  
Tomoshige Hori ◽  
Kensuke Itoh
2008 ◽  
Vol 130 (4) ◽  
Author(s):  
Calvin H. Li ◽  
Wesley Williams ◽  
Jacopo Buongiorno ◽  
Lin-Wen Hu ◽  
G. P. Peterson

Nanofluids are being studied for their potential to enhance heat transfer, which could have a significant impact on energy generation and storage systems. However, only limited experimental data on metal and metal-oxide based nanofluids, showing enhancement of the thermal conductivity, are currently available. Moreover, the majority of the data currently available have been obtained using transient methods. Some controversy exists as to the validity of the measured enhancement and the possibility that this enhancement may be an artifact of the experimental methodology. In the current investigation, Al2O3∕water nanofluids with normal diameters of 47nm at different volume fractions (0.5%, 2%, 4%, and 6%) have been investigated, using two different methodologies: a transient hot-wire method and a steady-state cut-bar method. The comparison of the measured data obtained using these two different experimental systems at room temperature was conducted and the experimental data at higher temperatures were obtained with steady-state cut-bar method and compared with previously reported data obtained using a transient hot-wire method. The arguments that the methodology is the cause of the observed enhancement of nanofluids effective thermal conductivity are evaluated and resolved. It is clear from the results that at room temperature, both the steady-state cut-bar and transient hot-wire methods result in nearly identical values for the effective thermal conductivity of the nanofluids tested, while at higher temperatures, the onset of natural convection results in larger measured effective thermal conductivities for the hot-wire method than those obtained using the steady-state cut-bar method. The experimental data at room temperature were also compared with previously reported data at room temperature and current available theoretical models, and the deviations of experimental data from the predicted values are presented and discussed.


Author(s):  
Marcelo Borges dos Santos ◽  
CLAUDIA BITTENCOURT ◽  
Ana Carolina Mendonça Mansur ◽  
Luís Mauro Moura ◽  
Carlos Augusto Castro Ferreira

1999 ◽  
Vol 29 ◽  
pp. 151-154 ◽  
Author(s):  
Crescenzo Festa ◽  
Aristide Rossi

AbstractAn apparatus is described for measuring the thermal conductivity of ice by the transient hot-wire method. Thermal conductivity A, is determined by tracking the thermal pulse induced in the sample by a heating source consisting of a platinum resistor. A central segment of the same platinum heating resistor acts also as a thermal sensor. A heat pulse transferred to the ice for a period of 40s gives a maximum temperature increment of about 7-14°C. In good experimental conditions, the expected reproducibility of the measurements is within ±3%. The accuracy of the method depends on whether the instrument has been calibrated by reliable standard samples, certified by absolute methods.


Author(s):  
Milivoje M. Kostic ◽  
Casey J. Walleck

A steady-state, parallel-plate thermal conductivity (PPTC) apparatus has been developed and used for comparative measurements of complex POLY-nanofluids, in order to compare results with the corresponding measurements using the transient, hotwire thermal conductivity (HWTC) apparatus. The related measurements in the literature, mostly with HWTC method, have been inconsistent and with measured thermal conductivities far beyond prediction using the well-known mixture theory. The objective was to check out if existing and well-established HWTC method might have some unknown issues while measuring TC of complex nano-mixture suspensions, like electro-magnetic phenomena, undetectable hot-wire vibrations, and others. These initial and limited measurements have shown considerable difference between the two methods, where the TC enhancements measured with PPTC apparatus were about three times smaller than with HWTC apparatus, the former data being much closer to the mixture theory prediction. However, the influence of measurement method is not conclusive since it has been observed that the complex nano-mixture suspensions were very unstable during the lengthy steady-state measurements as compared to rather quick transient HWTC method. The nanofluid suspension instability might be the main reason for very inconsistent results in the literature. It is necessary to expend investigation with more stable nano-mixture suspensions.